Mode-mismatched confocal thermal-lens microscope with collimated probe beam

被引:16
|
作者
Cabrera, Humberto [1 ,2 ]
Korte, Dorota [3 ]
Franko, Mladen [3 ]
机构
[1] Abdus Salaam Int Ctr Theoret Phys, SPIE ICTP Anchor Res Lab, Trieste, Italy
[2] Inst Venezolano Invest Cient IVIC, Ctr Multidisciplinartio Ciencias, Merida 5101, Venezuela
[3] Univ Nova Gorica, Environm Res Lab, Nova Gorica 5000, Slovenia
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2015年 / 86卷 / 05期
关键词
SPECTROMETRIC DETECTION; SEPARATION;
D O I
10.1063/1.4919735
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We report a thermal lens microscope (TLM) based on an optimized mode-mismatched configuration. It takes advantage of the coaxial counter propagating tightly focused excitation and collimated probe beams, instead of both focused at the sample, as it is in currently known TLM setups. A simple mathematical model that takes into account the main features of the instrument is presented. The confocal detection scheme and the introduction of highly collimated probe beam allow enhancing the versatility, limit of detection (LOD), and sensitivity of the instrument. The theory is experimentally verified measuring ethanol's absorption coefficient at 532.8 nm. Additionally, the presented technique is applied for detection of ultra-trace amounts of Cr(III) in liquid solution. The achieved LOD is 1.3 ppb, which represents 20-fold enhancement compared to transmission mode spectrometric techniques and a 7.5-fold improvement compared to previously reported methods for Cr(III) based on thermal lens effect. (C) 2015 AIP Publishing LLC.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Pump-probe mode-mismatched thermal-lens Z scan
    Marcano, A
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2002, 19 (01) : 119 - 124
  • [2] Confocal thermal-lens microscope
    Moreau, J
    Loriette, V
    OPTICS LETTERS, 2004, 29 (13) : 1488 - 1490
  • [3] PROBE BEAM IMAGE DETECTION FOR MODE-MISMATCHED DUAL-BEAM THERMAL LENS SPECTROMETRY
    SHEN, J
    SOROKA, AJ
    BAESSO, ML
    SNOOK, RD
    JOURNAL DE PHYSIQUE IV, 1994, 4 (C7): : 91 - 94
  • [5] Probe-beam diffraction in a pulsed top-hat beam thermal lens with a mode-mismatched configuration
    Li, BC
    Welsch, E
    APPLIED OPTICS, 1999, 38 (24) : 5241 - 5249
  • [6] Confocal dual-beam thermal-lens microscope: Model and experimental results
    Moreau, Julien
    Loriette, Vincent
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2006, 45 (9A): : 7141 - 7151
  • [7] Confocal dual-beam thermal-lens microscope: Model and experimental results
    Moreau, Julien
    Loriette, Vincent
    Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers, 2006, 45 (9 A): : 7141 - 7151
  • [8] Mode-mismatched thermal lens experiment in the pulse regime
    Marcano, A
    Rodriguez, L
    Alvarado, Y
    JOURNAL OF OPTICS A-PURE AND APPLIED OPTICS, 2003, 5 (05): : S256 - S261
  • [9] Development of Reflection Objective-Employed Collinear Mode-mismatched Thermal Lens Microscope
    Fujii, Noriyuki
    Harata, Akira
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2011, 50 (07)
  • [10] Mode-mismatched thermal lens experiment in the pulse regime
    Marcano, O
    Rodriguez, L
    Alvarado, Y
    OPTICS FOR THE QUALITY OF LIFE, PTS 1 AND 2, 2003, 4829 : 373 - 374