Volar Capsular Release After Distal Radius Fractures

被引:13
|
作者
Kamal, Robin N. [1 ]
Ruch, David S. [2 ]
机构
[1] Stanford Univ, Dept Orthopaed Surg, 450 Broadway St,Pavil C, Redwood City, CA 94063 USA
[2] Duke Univ, Dept Orthopaed Surg, Durham, NC USA
来源
关键词
Distal radius fracture; wrist fracture; wrist stiffness; carpal instability; POLLICIS LONGUS TENDON; LIGAMENT LENGTH CHANGES; HUMAN WRIST; SURGICAL-TREATMENT; PLATE FIXATION; JOINT CAPSULE; RUPTURE; INSTABILITY; PALMAR; FLEXION;
D O I
10.1016/j.jhsa.2017.08.002
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Loss of full wrist range of motion is common after treatment of distal radius fractures. Loss of wrist extension limiting functional activities, although uncommon, can occur after volar plating of distal radius fractures. Unlike other joints in which capsular release is a common form of treatment for stiffness, this has been approached with caution in the wrist owing to concerns for carpal instability. We tested the null hypothesis that hardware removal and open volar capsular release would not lead to improved upper extremity-specific patient-reported outcome (Disabilities of the Arm, Shoulder, and Hand [DASH] questionnaire). Methods We conducted a retrospective chart review of patients who underwent a tenolysis of the flexor carpi radialis tendon, removal of hardware, and subperiosteal release of the volar capsule (extrinsic ligaments). The primary outcome measure was patient-reported outcome on the DASH. Secondary outcomes included wrist flexion, extension, pronation, and supination, visual analog scale for pain, and radiographs/fluoroscopy for ulnocarpal translocation. Results Eleven patients were treated with a mean follow-up of 4.5 years. Mean DASH scores improved after surgery. Mean wrist flexion, wrist extension, pronation, and supination improved after surgery. Mean visual analog scale scores did not change. The radiocarpal relationship on radiographs/fluoroscopy was normal. Conclusions Open volar capsular release to regain wrist extension after treatment of distal radius fractures with volar locking plates is safe and effective. Patients regain wrist extension in addition to improved DASH scores. There were no radiographic/fluoroscopic or clinical signs of ulnocarpal translocation after release of the volar extrinsic ligaments. Copyright (C) 2017 by the American Society for Surgery of the Hand. All rights reserved.
引用
收藏
页码:1034.e1 / 1034.e6
页数:6
相关论文
共 50 条
  • [41] Breakage of volar locking plate system for distal radius fractures
    Kawanishi, Syohei
    Gato, Uasushi
    Nakai, Tsuyoshi
    ACTA ORTHOPAEDICA BELGICA, 2020, 86 (S 1): : 71 - 77
  • [42] Radiographic Outcomes of Volar Locked Plating for Distal Radius Fractures
    Mignemi, Megan E.
    Byram, Ian R.
    Wolfe, Carmen C.
    Fan, Kang-Hsien
    Koehler, Elizabeth A.
    Block, John J.
    Jordanov, Martin I.
    Watson, Jeffry T.
    Weikert, Douglas R.
    Lee, Donald H.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2013, 38A (01): : 40 - 48
  • [43] Complications of Volar Plating of Distal Radius Fractures: A Systematic Review
    Alter, Todd H.
    Sandrowski, Kristin
    Gallant, Gregory
    Kwok, Moody
    Ilyas, Asif M.
    JOURNAL OF WRIST SURGERY, 2019, 8 (03) : 255 - 262
  • [44] Volar Plate-Suture Fixation in the Treatment of Volar Rim Fractures of the Distal Radius
    Carney, John
    Bigach, Stephen
    Goedderz, Cody
    Gerlach, Erik
    Marx, Jeremy
    Kalainov, David
    JOURNAL OF WRIST SURGERY, 2025, 14 (01) : 57 - 62
  • [45] The Effect of Acute Distal Radioulnar Joint Laxity on Outcome After Volar Plate Fixation of Distal Radius Fractures
    Kim, Jae K.
    Yi, Ju W.
    Jeon, Sang H.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2013, 27 (12) : 735 - 739
  • [46] Volar Locking Plate Fixation for Distal Radius Fractures Distal to the Watershed Line with an Intact Lunate Volar Rim
    Cha, Soo Min
    Shin, Hyun Dae
    Kim, Seung Won
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2023, 28 (06): : 708 - 716
  • [47] Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius
    Rozental, TD
    Blazar, PE
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2006, 31A (03): : 359 - 365
  • [48] Early Functional Results after Volar Fixed-Angle Plating of Distal Radius Fractures
    Todor, A.
    Pojar, A.
    Arghius, C.
    Lucaciu, D.
    INTERNATIONAL CONFERENCE ON ADVANCEMENTS OF MEDICINE AND HEALTH CARE THROUGH TECHNOLOGY, 2011, 36 : 392 - +
  • [49] Evaluation of the Distal Extent of Visualization Using Volar Approaches for Fixation of Distal Radius Fractures
    Heifner, John J.
    Halpern, Abby L.
    Gomez, Osmanny
    Mercer, Deana M.
    Orbay, Jorge L.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2024, 49 (11): : 1144e1 - 1144e6
  • [50] Surgical treatment of unstable distal radius fractures with volar locking plates
    Murakami, Kenichi
    Abe, Yoshihiro
    Takahashi, Kazuhisa
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2007, 12 (02) : 134 - 140