Use of a real time continuous glucose monitoring system as an educational tool for patients with gestational diabetes

被引:30
|
作者
Alfadhli, Eman [1 ]
Osman, Eman [1 ]
Basri, Taghreed [2 ]
机构
[1] Taibah Univ, Medina, Saudi Arabia
[2] Madina Matern & Children Hosp, Medina, Saudi Arabia
来源
关键词
Gestational diabetes; Continuous glucose monitoring system; SMBG; Maternal glycemic control; Pregnancy outcomes; GLYCEMIC CONTROL; PREGNANCY;
D O I
10.1186/s13098-016-0161-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Women with gestational diabetes mellitus (GDM) are required to control their blood glucose shortly after GDM diagnosis to minimize adverse pregnancy outcomes. A real time-continuous glucose monitoring system (RT-CGMS) provides the patient with continuous information about the alterations in levels of the blood glucose. This visibility may empower the patient to modify her lifestyle and engage in therapeutic management. The aim of this study was to determine whether a single application of RT-CGMS to pregnant women shortly after GDM diagnosis is useful as an educational and motivational tool. Methods: This study was a prospective open label randomized controlled study conducted at Maternity and Children Hospital, Medina, Saudi Arabia. A total of 130 pregnant women with GDM were randomised to either blood glucose self-monitor alone (SMBG group) (n = 62) or in addition to SMBG, patients wore a Guardian (R) REAL-Time Continuous Glucose Monitoring System (Medtronic MiniMed) once for 3-7 days, within 2 weeks of GDM diagnosis (RT-CGMS group) (n = 68). The primary outcomes were maternal glycemic control and pregnancy outcomes. Secondary outcomes were the changes in parameters of glucose variability, which includes mean sensor readings, standard deviation (SD) of blood glucose, and area under the curve for hyper and hypoglycaemia at the end of the RT-CGMS application. Results: HbA1c, mean fasting and postprandial glucose levels were similar in both groups at the end of the pregnancy. Pregnancy outcomes were comparable. However, there was significant improvement in the parameters of glucose variability on the last day of sensor application; both mean glucose and the SD of mean glycaemia were reduced significantly; P = 0.016 and P = 0.034, respectively. The area under the curve for hyper and hypoglycaemia were improved, however, the results were not statistically significant. Conclusion: Although a single application of RT-CGMS shortly after GDM diagnosis is helpful as an educational tool, it was not associated with improvement in glycemic control or pregnancy outcomes.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Use of a real time continuous glucose monitoring system as an educational tool for patients with gestational diabetes
    Eman Alfadhli
    Eman Osman
    Taghreed Basri
    [J]. Diabetology & Metabolic Syndrome, 8
  • [2] Monthly use of a real-time continuous glucose monitoring system as an educational and motivational tool for poorly controlled type 1 diabetes adolescents
    Glowinska-Olszewska, B.
    Tobiaszewska, M.
    Luczynski, W.
    Bossowski, A.
    [J]. ADVANCES IN MEDICAL SCIENCES, 2013, 58 (02): : 344 - 352
  • [3] A Randomized Trial of Real-Time Continuous Glucose Monitoring in Gestational Diabetes
    Ehrhardt, Nicole M.
    Fay, Emily
    Abdalla, Ghada
    Mandava, Patali
    Fonda, Stephanie J.
    [J]. DIABETES, 2024, 73
  • [4] Real-Time Continuous Glucose Monitoring in Gestational Diabetes: A Randomized Controlled Trial
    Lane, Andrew S.
    Mlynarczyk, Malgorzata A.
    de Veciana, Margarita
    Green, Lauren M.
    Baraki, Dana I.
    Abuhamad, Alfred Z.
    [J]. AMERICAN JOURNAL OF PERINATOLOGY, 2019, 36 (09) : 891 - 897
  • [5] Use of real time continuous glucose monitoring system as a motivational device for type 2 diabetes
    Yoo, Hye Jin
    Kim, Hae Sook
    Yang, Sae Jeong
    Park, Ju Ri
    Kim, Tae Nyun
    Lee, Yun Jeong
    Park, Soo Yeon
    Kim, Hee Young
    Lee, Kye Won
    Seo, Ji A.
    Shin, Dong Hyun
    Kim, Sin Gon
    Kim, Nan Hee
    Choi, Kyung Mook
    Choi, Dong Seop
    Baik, Sei Hyun
    [J]. DIABETES, 2008, 57 : A555 - A555
  • [6] Use of intermittently scanned continuous glucose monitoring in gestational diabetes
    Alington, K.
    Cranston, I. C.
    Cummings, M. H.
    [J]. DIABETIC MEDICINE, 2023, 40
  • [7] Type 2 Diabetes and the Use of Real-Time Continuous Glucose Monitoring
    Jackson, Melanie A.
    Ahmann, Andrew
    Shah, Viral N.
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 : S27 - S34
  • [8] Continuous glucose monitoring for the evaluation of gestational diabetes mellitus patients
    Chen, R
    Yogev, Y
    Ben-Haroush, A
    Peled, Y
    Jovanovic, L
    Hod, M
    Phillip, M
    [J]. DIABETOLOGIA, 2002, 45 : A289 - A289
  • [9] Use of a real time continuous glucose monitoring system as a motivational device for poorly controlled type 2 diabetes
    Yoo, H. J.
    An, H. G.
    Park, S. Y.
    Ryu, O. H.
    Kim, H. Y.
    Seo, J. A.
    Hong, E. G.
    Shin, D. H.
    Kim, Y. H.
    Kim, S. G.
    Choi, K. M.
    Park, I. B.
    Yu, J. M.
    Baik, S. H.
    [J]. DIABETES RESEARCH AND CLINICAL PRACTICE, 2008, 82 (01) : 73 - 79
  • [10] Real-time continuous glucose monitoring system for treatment of diabetes: a systematic review
    Hoeks, L. B. E. A.
    Greven, W. L.
    de Valk, H. W.
    [J]. DIABETIC MEDICINE, 2011, 28 (04) : 386 - 394