Ultra-high resolution optical coherence tomography (OCT) using a halogen lamp as the light source

被引:27
|
作者
Ohmi, M [1 ]
Haruna, M [1 ]
机构
[1] Osaka Univ, Grad Sch Med, Course Allied Hlth Sci, Suita, Osaka 5650871, Japan
关键词
D O I
10.1007/s10043-003-0478-9
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The axial resolution of optical coherence tomography (OCT) is determined by the coherence length of the light source. We demonstrate for the first time high-resolution OCT of biological tissue using a halogen lamp as the light source for a low coherence interferometer. High-resolution OCT imaging with 3.5 mum resolution was performed successfully for onion and porcine skin, although the coherence light power for illumination of a sample is as small as 100 nW.
引用
收藏
页码:478 / 481
页数:4
相关论文
共 50 条
  • [31] Quantitative analysis of the intraretinal layers and optic nerve head using ultra-high resolution optical coherence tomography
    Wang, Yuhong
    Jiang, Hong
    Shen, Meixiao
    Lam, Byron L.
    DeBuc, Delia Cabrera
    Ye, Yufeng
    Li, Ming
    Tao, Aizhu
    Shao, Yilei
    Wang, Jianhua
    JOURNAL OF BIOMEDICAL OPTICS, 2012, 17 (06)
  • [32] Improvement of axial resolution for optical coherence tomography using a synthesized light source
    Sato, M
    Wakaki, I
    Watanabe, Y
    Tanno, N
    ROMOPTO 2003: SEVENTH CONFERENCE ON OPTICS, 2004, 5581 : 662 - 669
  • [33] Optical coherence tomography: High resolution imaging using echoes of light
    Fujimoto, James G.
    Drexler, Wolfgang
    Morgner, Uwe
    Kartner, Franz
    Ippen, Erich
    Optics and Photonics News, 2000, 11 (01): : 23 - 31
  • [34] Retinal Laser Lesion Visibility in Simultaneous Ultra-High Axial Resolution Optical Coherence Tomography
    Steiner, Patrick
    Enzmann, Volker
    Meier, Christoph
    Povazay, Boris
    Kowal, Jens H.
    IEEE PHOTONICS JOURNAL, 2014, 6 (06):
  • [35] Ultra-high resolution optical coherence tomography assessment of photoreceptors in retinitis pigmentosa and related diseases
    Witkin, Andre J.
    Ko, Tony H.
    Fujimoto, James G.
    Chan, Annie
    Drexler, Wolfgang
    Schuman, Joel S.
    Reichel, Elias
    Duker, Jay S.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 142 (06) : 945 - 952
  • [36] Ultra-High Resolution Optical Coherence Tomography for Differentiation of Ocular Surface Squamous Neoplasia and Pterygia
    Kieval, Jeremy Z.
    Karp, Carol L.
    Abou Shousha, Mohamed
    Galor, Anat
    Hoffman, Rodrigo A.
    Dubovy, Sander R.
    Wang, Jianhua
    OPHTHALMOLOGY, 2012, 119 (03) : 481 - 486
  • [37] Ultra-High Resolution Fiber Based Polarization Sensitive Spectral Domain Optical Coherence Tomography
    Goetzinger, Erich
    Pircher, Michael
    Baumann, Bernhard
    Hitzenberger, Christoph K.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XIV, 2010, 7554
  • [38] Photoreceptor Lengthening During Dark Adaptation Detected With Ultra-High Resolution Optical Coherence Tomography
    Lu, Chen D.
    Choi, Woo Jhon
    Wang, Zhao
    Kraus, Martin F.
    Hornegger, Joachim
    Duker, Jay S.
    Fujimoto, James G.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [39] Glass-clad Crystal Fiber based Ultra-high Resolution Optical Coherence Tomography
    Wang, Y. T.
    Tsai, C. C.
    Hsu, K. Y.
    Lin, Y. S.
    Jheng, D. Y.
    Huang, K. Y.
    Huang, S. L.
    Yeh, P. S.
    2009 LASERS & ELECTRO-OPTICS & THE PACIFIC RIM CONFERENCE ON LASERS AND ELECTRO-OPTICS, VOLS 1 AND 2, 2009, : 1293 - 1293
  • [40] Measurement of the retention time of different ophthalmic formulations with ultra-high resolution Optical Coherence Tomography
    Amato, Roberta
    Gagliano, Caterina
    Malaguarnera, Giulia
    Reibaldi, Michele
    Longo, Antonio
    Papa, Vincenzo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)