Ultra-high resolution optical coherence tomography (OCT) using a halogen lamp as the light source

被引:27
|
作者
Ohmi, M [1 ]
Haruna, M [1 ]
机构
[1] Osaka Univ, Grad Sch Med, Course Allied Hlth Sci, Suita, Osaka 5650871, Japan
关键词
D O I
10.1007/s10043-003-0478-9
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The axial resolution of optical coherence tomography (OCT) is determined by the coherence length of the light source. We demonstrate for the first time high-resolution OCT of biological tissue using a halogen lamp as the light source for a low coherence interferometer. High-resolution OCT imaging with 3.5 mum resolution was performed successfully for onion and porcine skin, although the coherence light power for illumination of a sample is as small as 100 nW.
引用
收藏
页码:478 / 481
页数:4
相关论文
共 50 条
  • [1] Ultra-High Resolution Optical Coherence Tomography (OCT) Using a Halogen Lamp as the Light Source
    Masato Ohmi
    Masamitsu Haruna
    Optical Review, 2003, 10 : 478 - 481
  • [2] Ultra-high resolution spectral domain optical coherence tomography using supercontinuum light source
    Yiheng Lim
    Toyohiko Yatagai
    Yukitoshi Otani
    Optical Review, 2016, 23 : 180 - 186
  • [3] Ultra-high resolution spectral domain optical coherence tomography using supercontinuum light source
    Lim, Yiheng
    Yatagai, Toyohiko
    Otani, Yukitoshi
    OPTICAL REVIEW, 2016, 23 (02) : 180 - 186
  • [4] Ultra-high speed and ultra-high resolution optical coherence tomography and optical Doppler tomography
    de Boer, JF
    Cense, B
    Nassif, N
    White, BR
    Park, BH
    Pierce, MC
    Tearney, GJ
    Bouma, BE
    Chen, TC
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [5] Ultra-high speed and ultra-high resolution optical coherence tomography and optical Doppler tomography
    de Boer, JF
    Cense, B
    Nassif, N
    White, BR
    Park, BH
    Pierce, MC
    Tearney, GJ
    Bouma, BE
    Chen, TC
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U414 - U414
  • [6] Investigation on spectral-domain optical coherence tomography using a tungsten halogen lamp as light source
    Yuping Chen
    Hong Zhao
    Zhao Wang
    Optical Review, 2009, 16 : 26 - 29
  • [7] Investigation on spectral-domain optical coherence tomography using a tungsten halogen lamp as light source
    Chen, Yuping
    Zhao, Hong
    Wang, Zhao
    OPTICAL REVIEW, 2009, 16 (01) : 26 - 29
  • [8] Accuracy and Repeatability of Ultra-High Resolution Optical Coherence Tomography
    Hutchings, N.
    Hyun, C.
    Mishra, A.
    Bizheva, K.
    Simpson, T.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [9] A comparative study of noise in supercontinuum light sources for ultra-high resolution Optical Coherence Tomography
    Maria, M.
    Gonzalo, I. B.
    Bondu, M.
    Engelsholm, R. D.
    Feuchter, T.
    Moselund, P. M.
    Leick, L.
    Bang, O.
    Podoleanu, A.
    DESIGN AND QUALITY FOR BIOMEDICAL TECHNOLOGIES X, 2017, 10056
  • [10] Measurement of Ciliary Beat Frequency Using Ultra-High Resolution Optical Coherence Tomography
    Chen, Jason J.
    Jing, Joseph C.
    Su, Erica
    Badger, Christopher
    Coughlan, Carolyn A.
    Chen, Zhongping
    Wong, Brian J. F.
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS XII, 2016, 9689