In type 1 diabetes, real-time vs. intermittently scanned continuous glucose monitoring improved glycemic control

被引:2
|
作者
Olson, Darin E. [1 ]
机构
[1] Colorado Mt Med, Edwards, CO 81632 USA
关键词
D O I
10.7326/ACPJ202110190-119
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:JC119 / JC119
页数:1
相关论文
共 50 条
  • [31] MODERATOR ANALYSES OF THE COMPARISON BETWEEN REAL-TIME AND INTERMITTENTLY SCANNED CONTINUOUS GLUCOSE MONITORING IN ADULTS WITH TYPE 1 DIABETES: A SUB-ANALYSIS OF THE ALERTT1 TRIAL
    Visser, M.
    Charleer, S.
    Fieuws, S.
    De Block, C.
    Hilbrands, R.
    Van Huffel, L.
    Maes, T.
    Vanhaverbeke, G.
    Dirinck, E.
    Myngheer, N.
    Vercammen, C.
    Nobels, F.
    Keymeulen, B.
    Mathieu, C.
    Gillard, P.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2022, 24 : A141 - A141
  • [32] COMPARING REAL-TIME AND INTERMITTENTLY SCANNED CONTINUOUS GLUCOSE MONITORING IN ADULTS WITH TYPE 1 DIABETES: THE SIX-MONTH MULTICENTER RANDOMIZED CONTROLLED ALERTT1 TRIAL
    Visser, M.
    Charleer, S.
    Fieuws, S.
    Hilbrands, R.
    Maes, T.
    De Block, C.
    Vanhaverbeke, G.
    Dirinck, E.
    Myngheer, N.
    Nobels, F.
    Keymeulen, B.
    Mathieu, C.
    Gillard, P.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 : A30 - A31
  • [33] Impact of Switching from Intermittently Scanned to Real-Time Continuous Glucose Monitoring Systems in a Type 1 Diabetes Patient French Cohort: An Observational Study of Clinical Practices
    Preau, Yannis
    Armand, Martine
    Galie, Sebastien
    Schaepelynck, Pauline
    Raccah, Denis
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 (04) : 259 - 267
  • [34] Performance of intermittently scanned continuous glucose monitoring systems in people with type 1 diabetes: A pooled analysis
    Moser, Othmar
    Sternad, Christoph
    Eckstein, Max L.
    Szadkowska, Agnieszka
    Michalak, Arkadiusz
    Mader, Julia K.
    Ziko, Haris
    Elsayed, Hesham
    Aberer, Felix
    Sola-Gazagnes, Agnes
    Larger, Etienne
    Fadini, Gian Poalo
    Bonora, Benedetta Maria
    Bruttomesso, Daniela
    Boscari, Federico
    Freckmann, Guido
    Pleus, Stefan
    Christiansen, Sverre C.
    Sourij, Harald
    DIABETES OBESITY & METABOLISM, 2022, 24 (03): : 522 - 529
  • [35] DIABETES Under Control Real-Time Continuous Glucose Monitoring
    Ramchandani, Neesha
    Saadon, Yael
    Jornsay, Donna
    AMERICAN JOURNAL OF NURSING, 2010, 110 (04) : 60 - 63
  • [36] The accuracy of capillary blood glucose testing versus real time and intermittently scanned continuous glucose monitoring
    El-Abd, Souha
    Poole, Ruth
    PRACTICAL DIABETES, 2023, 40 (05) : 40 - +
  • [37] The Impact of Baseline User Characteristics on the Benefits of Real-Time Versus Intermittently Scanned Continuous Glucose Monitoring in Adults With Type 1 Diabetes: Moderator Analyses of the ALERTT1 Trial
    Visser, Margaretha Martha
    Charleer, Sara
    Fieuws, Steffen
    De Block, Christophe
    Hilbrands, Robert
    Van Huffel, Liesbeth
    Maes, Toon
    Vanhaverbeke, Gerd
    Dirinck, Eveline
    Myngheer, Nele
    Vercammen, Chris
    Nobels, Frank
    Keymeulen, Bart
    Mathieu, Chantal
    Gillard, Pieter
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2024, 18 (03): : 660 - 666
  • [38] Comparing real-time and intermittently scanned continuous glucose monitoring in adults with type 1 diabetes (ALERTT1): a 6-month, prospective, multicentre, randomised controlled trial
    Visser, Margaretha M.
    Charleer, Sara
    Fieuws, Steffen
    De Block, Christophe
    Hilbrands, Robert
    Van Huffel, Liesbeth
    Maes, Toon
    Vanhaverbeke, Gerd
    Dirinck, Eveline
    Myngheer, Nele
    Vercammen, Chris
    Nobels, Frank
    Keymeulen, Bart
    Mathieu, Chantal
    Gillard, Pieter
    LANCET, 2021, 397 (10291): : 2275 - 2283
  • [39] RELATIONSHIP BETWEEN HEMOGLOBIN A1C, TIME-IN-RANGE AND GLYCEMIC VARIABILITY IN TYPE 1 DIABETES PATIENTS UNDER INTERMITTENTLY SCANNED CONTINUOUS GLUCOSE MONITORING.
    Diaz Soto, G.
    Gomez Hoyos, E.
    Jimenez, R.
    Nieto De La Marca, M. D. L. O.
    Vidueira, A. M.
    De Luis, D.
    Bahillo Curieses, P.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2020, 22 : A124 - A124
  • [40] Continuous home monitoring of glucose - Improved glycemic control with real-life use of continuous glucose sensors in adult subjects with type 1 diabetes
    Garg, Satish K.
    Kelly, William C.
    Voelmle, Mary K.
    Ritchie, Peter J.
    Gottlieb, Peter A.
    McFann, Kim K.
    Ellis, Samuel L.
    DIABETES CARE, 2007, 30 (12) : 3023 - 3025