A facile electrochemical sensor based on a composite of electrochemically reduced graphene oxide and a PEDOT:PSS modified glassy carbon electrode for uric acid detection

被引:24
|
作者
Putra, Budi R. [1 ]
Nisa, Ulfiatun [2 ]
Heryanto, Rudi [2 ,3 ]
Rohaeti, Eti [2 ]
Khalil, Munawar [4 ]
Izzataddini, Arini [5 ]
Wahyuni, Wulan T. [2 ,3 ]
机构
[1] Indonesia Def Univ, Kawasan IPSC Sentul, Fac Math & Nat Sci, Dept Chem, Bogor 16810, Indonesia
[2] Fac Math & Nat Sci, Dept Chem, Div Analyt Chem, Kampus IPB, Bogor 16680, Indonesia
[3] IPB Univ, Inst Res & Community Empowerment, Trop Biopharm Res Ctr, Bogor 16680, Indonesia
[4] Univ Indonesia, Fac Math & Nat Sci, Dept Chem, Depok 16424, Indonesia
[5] Univ Malaya, Dept Chem Engn, Fac Engn, Kuala Lumpur 50603, Malaysia
关键词
Electrochemically reduced graphene oxide; PEDOT; PSS; Uric acid; Dopamine; Artificial saliva; SELECTIVE SENSOR; ASCORBIC-ACID; NANOCOMPOSITE; REDUCTION; DOPAMINE; FILMS; SALIVA; CHROMATOGRAPHY;
D O I
10.2116/analsci.21P214
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A glassy carbon electrode modified with electrochemically reduced graphene oxide (ErGO) and poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) was developed for uric acid determination with dopamine as interference in artificial saliva. The electrochemical performance of the fabricated electrode was studied using both techniques of cyclic voltammetry (CV) and differential pulse voltammetry (DPV), under optimized conditions. Using DPV, the sensor based on ErGO/PEDOT:PSS modified GCE displayed a linear relationship in the concentration ranges of 10-100 mu M for uric acid. This uric acid sensor exhibited a high sensitivity with detection limits of 1.08 mu M and quantitation limit of 3.61 mu M. This sensor also showed good reproducibility for uric acid detection in artificial saliva in 5 consecutive days of measurements. This device was successfully used to analyze uric acid in artificial saliva as well as in a human saliva sample using the standard addition method.
引用
收藏
页码:157 / 166
页数:10
相关论文
共 50 条
  • [31] Electrochemical sensor for Isoniazid based on the glassy carbon electrode modified with reduced graphene oxide-Au nanomaterials
    Guo, Zhuo
    Wang, Ze-yu
    Wang, Hui-hua
    Huang, Guo-qing
    Li, Meng-meng
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2015, 57 : 197 - 204
  • [32] Ultrasensitive Determination of Dopamine and Uric Acid Based on Gold Nanoparticles@Carbon Dots/Electrochemical Reduced Graphene Oxide modified glassy carbon electrode
    Li, Muyi
    Yang, Xiang
    Liu, Wenjun
    Wang, Huixian
    Jiang, Hongmei
    Liu, Xiaoying
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2021, 16 (08): : 1 - 17
  • [33] Simultaneous Electrochemical Determination of Ascorbic Acid, Dopamine and Uric Acid Based on Reduced Graphene Oxide-Ag/PANI Modified Glassy Carbon Electrode
    Guo Zhuo
    Luo Xianke
    Li Yahui
    Li Dongdi
    Zhao Qinai
    Li Mengmeng
    Ma Chi
    Zhao Yanting
    CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2017, 33 (03) : 507 - 512
  • [34] Simultaneous electrochemical determination of ascorbic acid, dopamine and uric acid based on reduced graphene oxide-Ag/PANI modified glassy carbon electrode
    Zhuo Guo
    Xianke Luo
    Yahui Li
    Dongdi Li
    Qinai Zhao
    Mengmeng Li
    Chi Ma
    Yanting Zhao
    Chemical Research in Chinese Universities, 2017, 33 : 507 - 512
  • [35] Amperometric Detection of Dopamine based on a Graphene Oxide/PEDOT:PSS Composite Electrode
    Hardi, Gilar Wisnu
    Rahman, Siti Fauziyah
    INTERNATIONAL JOURNAL OF TECHNOLOGY, 2020, 11 (05) : 974 - 983
  • [36] Direct Electrochemistry of Eugenol at a Glassy Carbon Electrode Modified with Electrochemically Reduced Graphene Oxide
    Wang, Shijie
    Zhang, Ting
    Wang, Zhe
    Wang, Dong
    Wang, Zhao
    Sun, Mojie
    Song, Xiaochen
    Liu, Hong
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (04): : 3618 - 3627
  • [37] Electrochemically synthesized partially reduced graphene oxide modified glassy carbon electrode for individual and simultaneous voltammetric determination of ascorbic acid, dopamine and uric acid
    Aneesh, Padamadathil K.
    Nambiar, Sindhu R.
    Rao, Talasila P.
    Ajayaghosh, Ayyappanpillai
    ANALYTICAL METHODS, 2014, 6 (14) : 5322 - 5330
  • [38] Voltammetric uric acid sensor based on a glassy carbon electrode modified with a nanocomposite consisting of polytetraphenylporphyrin, polypyrrole, and graphene oxide
    Dai, Hongxiu
    Wang, Nan
    Wang, Donglei
    Zhang, Xiaomei
    Ma, Houyi
    Lin, Meng
    MICROCHIMICA ACTA, 2016, 183 (11) : 3053 - 3059
  • [39] Voltammetric uric acid sensor based on a glassy carbon electrode modified with a nanocomposite consisting of polytetraphenylporphyrin, polypyrrole, and graphene oxide
    Hongxiu Dai
    Nan Wang
    Donglei Wang
    Xiaomei Zhang
    Houyi Ma
    Meng Lin
    Microchimica Acta, 2016, 183 : 3053 - 3059
  • [40] Simultaneous electrochemical detection of dopamine and ascorbic acid using an iron oxide/reduced graphene oxide modified glassy carbon electrode
    Peik-See, Teo
    Pandikumar, Alagarsamy
    Nay-Ming, Huang
    Hong-Ngee, Lim
    Sulaiman, Yusran
    Sensors (Switzerland), 2014, 14 (08): : 15227 - 15243