Stochastic response of structures with hybrid base isolation systems

被引:17
|
作者
Markou, Athanasios A. [1 ]
Stefanou, George [2 ]
Manolis, George D. [2 ]
机构
[1] Aalto Univ, FI-02150 Espoo, Finland
[2] Aristotle Univ Thessaloniki, Thessaloniki 54124, Greece
基金
欧盟地平线“2020”;
关键词
Stochastic response; High damping rubber bearings; Low friction sliding bearings; Hybrid base isolation system; Trilinear hysteretic model; Nonlinear response; Monte-Carlo simulations; LIQUID STORAGE TANKS; ISOLATED BUILDINGS; SEISMIC ISOLATION; IDENTIFICATION; PARAMETERS; DESIGN; MODELS; OPTIMIZATION; EXCITATION; SIMULATION;
D O I
10.1016/j.engstruct.2018.06.051
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In 2004, two R/C residential buildings were retrofitted by using a hybrid base isolation system in Solarino, Sicily, and subsequently five free vibration tests were carried out in one of these buildings. The hybrid base isolation system combined high damping rubber bearings with low friction sliders. In terms of numerical modeling, a single-degree-of-freedom system is developed here with a new five-parameter trilinear hysteretic model for the simulation of the high damping rubber bearing, coupled with a Coulomb friction model for the simulation of the low friction slider. Furthermore, a shear beam type, four-degree-of-freedom model is used to numerically simulate the superstructure. Next, experimentally obtained data from the five initial-displacement, free vibration tests were used for the calibration of this six-parameter model describing the base isolation system. Following up on the model development, the present study employs Monte-Carlo simulations in order to investigate the effect of the unavoidable variation in the values of the six-parameter mechanical model on the response of both the hybrid base isolation system and the superstructure comprising the Solarino building. The calibrated parameters values from all the experiments are used as mean values, while the standard deviation for each parameter is deduced from the identification tests employing best-fit optimization for each experiment separately. The results of the Monte-Carlo simulations show that variation in the material parameters of the base isolation system produce a nonstationary effect in the response, which can be traced by the time evolution of its mean and standard deviation as computed from the response at different time instants. In addition, there is a magnification effect, since the coefficient of variation of the response, for most of the parameters, is larger than the coefficient of variation in the parameter values. The high level of nonlinearity in the base isolation system, as observed in the amplitude of vibration brought about by large initial displacements, helps explain the previously mentioned effects.
引用
下载
收藏
页码:629 / 643
页数:15
相关论文
共 50 条
  • [21] STOCHASTIC SENSITIVITY AND UNCERTAINTY OF SECONDARY SYSTEMS IN BASE-ISOLATED STRUCTURES
    JUHN, G
    MANOLIS, GD
    JOURNAL OF SOUND AND VIBRATION, 1992, 159 (02) : 207 - 222
  • [22] SEISMIC RESPONSE OF HEAVILY DAMPED BASE-ISOLATION SYSTEMS
    TSAI, HC
    KELLY, JM
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1993, 22 (07): : 633 - 645
  • [23] Constrained optimization for 1-D dynamic and earthquake response analysis of hybrid base-isolation systems
    Oliveto, Giuseppe
    Oliveto, Nicholas D.
    Athanasiou, Anastasia
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2014, 67 : 44 - 53
  • [24] Dynamic assessment of base isolation systems for irregular in plan structures: Response spectrum analysis vs nonlinear analysis
    Cancellara, Donato
    De Angelis, Fabio
    COMPOSITE STRUCTURES, 2019, 215 : 98 - 115
  • [25] A comparison of the effect of SSI on base isolation systems and fixed-base structures for soft soil
    Karabork, T.
    Deneme, I. O.
    Bilgehan, R. P.
    GEOMECHANICS AND ENGINEERING, 2014, 7 (01) : 87 - 103
  • [26] Evaluation of the dynamic response of structures using auxetic-type base isolation
    Naidoo, Preyolin
    Drosopoulos, Georgios
    FRATTURA ED INTEGRITA STRUTTURALE, 2020, (51): : 52 - 70
  • [27] Dynamic response characteristics of seismic isolation systems for building structures
    Beom-Soo Kang
    Le Li
    Tae-Wan Ku
    Journal of Mechanical Science and Technology, 2009, 23 : 2179 - 2192
  • [28] Dynamic response characteristics of seismic isolation systems for building structures
    Kang, Beom-Soo
    Li, Le
    Ku, Tae-Wan
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2009, 23 (08) : 2179 - 2192
  • [29] BASE ISOLATION SYSTEMS FOR EARTHQUAKE PROTECTION OF MULTI-STOREY SHEAR STRUCTURES
    LEE, DM
    MEDLAND, IC
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1979, 7 (06): : 555 - 568
  • [30] Effect of base isolation systems on increasing the resistance of structures subjected to progressive collapse
    Tavakoli, Hamid R.
    Naghavia, Fahime
    Goltabarb, Ali R.
    Earthquake and Structures, 2015, 9 (03): : 639 - 656