Optical Waveguide Biosensor Based on Cascaded Mach-Zehnder Interferometer and Ring Resonator with Vernier Effect

被引:3
|
作者
Jiang, Xianxin [1 ]
Tang, Longhua [1 ]
Song, Jinyan [1 ]
Li, Mingyu [1 ]
He, Jian-Jun [1 ]
机构
[1] Zhejiang Univ, Ctr Integrated Optoelect, Dept Opt Engn, State Key Lab Modern Opt Instrumentat, Hangzhou 310027, Zhejiang, Peoples R China
关键词
Optical waveguide sensor; microring; Mach-Zehnder interferometer; Vernier effect; SILICON; SENSORS;
D O I
10.1117/12.2077943
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Optical waveguide biosensors based on silicon-on-insulator (SOI) have been extensively investigated owing to its various advantages and many potential applications. In this article, we demonstrate a novel highly sensitive biosensor based on cascaded Mach-Zehnder interferometer (MZI) and ring resonator with the Vernier effect using wavelength interrogation. The experimental results show that the sensitivity reached 1,960 nm/RIU and 19,100 nm/RIU for sensors based on MZI alone and cascaded MZI-ring with Vernier effect, respectively. A biosensing application was also demonstrated by monitoring the interaction between goat and antigoat immunoglobulin G (IgG) pairs. This integrated high sensitivity biosensor has great potential for medical diagnostic applications.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Multiplexed Mach-Zehnder interferometer assisted ring resonator sensor
    Yadav, Mukesh
    Aksnes, Astrid
    OPTICS EXPRESS, 2022, 30 (02) : 1388 - 1396
  • [22] Sensitivity-Enhanced Temperature Sensor of Cascaded Lyot Filter and Mach-Zehnder Interferometer Based on the Vernier Effect
    Tian, Kaidi
    Wang, Zicheng
    Wang, Guochen
    Wu, Xingliang
    Wang, Yongguang
    IEEE SENSORS JOURNAL, 2024, 24 (15) : 23918 - 23928
  • [23] Mach-Zehnder interferometer as a temperature sensor based on the nested fiber ring resonator
    Zhang, Yundong
    Yu, Changqiu
    Wang, Kaiyang
    Xu, Chi
    Wang, Haiping
    Zhang, Yuhua
    2013 SEVENTH INTERNATIONAL CONFERENCE ON SENSING TECHNOLOGY (ICST), 2013, : 226 - 229
  • [24] Ultra-compact optical filter with rectangular ring resonator and Mach-Zehnder interferometer
    Wang, Shuang
    Liu, Ke
    Guangxue Xuebao/Acta Optica Sinica, 2015, 35 (05):
  • [25] Paralleled Sagnac interferometer and Mach-Zehnder interferometer for enhanced measurements sensitivity based on Vernier effect
    Shi, Ruyue
    Chen, Hailiang
    Li, Hongwei
    Liu, Chaoyi
    Li, Lida
    Yang, Sigang
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2024, 57 (16)
  • [26] Twist detection Mach-Zehnder interferometer based on optical vernier effect and its phase demodulation system
    Wang, Xingkai
    Liu, Chunlan
    Wei, Yong
    Liu, Chunbiao
    Shi, Chen
    Yang, Minghui
    Chen, Liping
    Liu, Zhihai
    MEASUREMENT, 2024, 235
  • [27] Highly sensitive Mach-Zehnder interferometer biosensor based on silicon nitride slot waveguide
    Liu, Qing
    Tu, Xiaoguang
    Kim, Kyung Woo
    Kee, Jack Sheng
    Shin, Yong
    Han, Kyungsup
    Yoon, Yong-Jin
    Lo, Guo-Qiang
    Park, Mi Kyoung
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 188 : 681 - 688
  • [28] Electrical waveguide in Mach-Zehnder modulator integrated into ring resonator for optical signal processing
    Enning, B
    ELECTRONICS LETTERS, 2006, 42 (01) : 49 - 50
  • [29] Cascaded Mach-Zehnder Interferometers With Vernier Effect for Gas Pressure Sensing
    Zhao, Yujia
    Lin, Hongfeng
    Zhou, Ciming
    Deng, Hongchang
    Zhou, Ai
    Yuan, Libo
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2019, 31 (08) : 591 - 594
  • [30] Nested ring Mach-Zehnder interferometer
    Darmawan, S.
    Landobasa, Y. M.
    Chin, M. K.
    OPTICS EXPRESS, 2007, 15 (02): : 437 - 448