Sensitivity and Specificity of Dual-Isotope 99mTc-Tetrofosmin and 123I Sodium Iodide Single Photon Emission Computed Tomography (SPECT) in Hyperparathyroidism

被引:10
|
作者
Sommerauer, Michael [1 ]
Graf, Carmen [1 ]
Schaefer, Niklaus [1 ]
Huber, Gerhard [2 ]
Schneider, Paul [3 ]
Wuethrich, Rudolf [4 ]
Schmid, Christoph [5 ]
Steinert, Hans [1 ]
机构
[1] Univ Zurich Hosp, Dept Nucl Med, CH-8091 Zurich, Switzerland
[2] Univ Zurich Hosp, Dept Otorhinolaryngol Head & Neck Surg, CH-8091 Zurich, Switzerland
[3] Univ Zurich Hosp, Dept Gen Visceral & Transplant Surg, CH-8091 Zurich, Switzerland
[4] Univ Zurich Hosp, Div Nephrol, CH-8091 Zurich, Switzerland
[5] Univ Zurich Hosp, Div Endocrinol & Diabetol, CH-8091 Zurich, Switzerland
来源
PLOS ONE | 2015年 / 10卷 / 06期
关键词
PARATHYROID SCINTIGRAPHY; SECONDARY HYPERPARATHYROIDISM; TC-99M-SESTAMIBI SPECT/CT; PHASE TC-99M-SESTAMIBI; C-11-METHIONINE PET/CT; SUBTRACTION SPECT; SESTAMIBI; SURGERY; I-123/TC-99M-SESTAMIBI; EXPLORATIONS;
D O I
10.1371/journal.pone.0129194
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose Despite recommendations for Tc-99m-tetrofosmin dual tracer imaging for hyperparathyroidism in current guidelines, no report was published on dual-isotope Tc-99m-tetrofosmin and I-123 sodium iodide single-photon-emission-computed-tomography (SPECT). We evaluated diagnostic accuracy and the impact of preoperative SPECT on the surgical procedures and disease outcomes. Methods Analysis of 70 consecutive patients with primary hyperparathyroidism and 20 consecutive patients with tertiary hyperparathyroidism. Imaging findings were correlated with surgical results. Concomitant thyroid disease, pre- and postoperative laboratory measurements, histopathological results, type and duration of surgery were assessed. Results In primary hyperparathyroidism, SPECT had a sensitivity of 80% and a positive predictive value of 93% in patient-based analysis. Specificity was 99% in lesion-based analysis. Patients with positive SPECT elicit higher levels of parathyroid hormone and higher weight of resected parathyroids than SPECT-negative patients. Duration of parathyroid surgery was on average, approximately 40 minutes shorter in SPECT-positive than in SPECT-negative patients (89 +/- 46 vs. 129 +/- 41 minutes, p=0.006); 86% of SPECT-positive and 50% of SPECT-negative patients had minimal invasive surgery (p = 0.021). SPECT had lower sensitivity (60%) in patients with tertiary hyperparathyroidism; however, 90% of these patients had multiple lesions and all of these patients had bilateral lesions. Conclusion Dual-isotope SPECT with Tc-99m-tetrofosmin and I-123 sodium iodide has a high diagnostic value in patients with primary hyperparathyroidism and allows for saving of operation time. Higher levels of parathyroid hormone and higher glandular weight facilitated detection of parathyroid lesion. Diagnostic accuracy of preoperative imaging was lower in patients with tertiary hyperparathyroidism.
引用
收藏
页数:11
相关论文
共 50 条
  • [11] Model-based crosstalk compensation for simultaneous 99mTc/123I dual-isotope brain SPECT imaging
    Du, Yong
    Tsui, Benjamin M. W.
    Frey, Eric C.
    MEDICAL PHYSICS, 2007, 34 (09) : 3530 - 3543
  • [12] Gated 99mTc-tetrofosmin single-photon emission computed tomography for differentiation of myocardial scar from attenuation artifact
    Fleischmann, S
    Namdar, M
    Koepfli, P
    Kaufmann, PA
    EUROPEAN HEART JOURNAL, 2003, 24 : 444 - 444
  • [13] Scatter correction based on an artificial neural network for 99mTc and 123I dual-isotope SPECT in myocardial and brain imaging
    Bai, Jingming
    Hashimoto, Jun
    Ogawa, Koichi
    Nakahara, Tadaki
    Suzuki, Takayuki
    Kubo, Atsushi
    ANNALS OF NUCLEAR MEDICINE, 2007, 21 (01) : 25 - 32
  • [14] A Crosstalk Compensation for Simultaneous 99mTc/123I Dual-isotope SPECT Imaging by Filtering Technique and Artificial Neural Network
    Chuang, K. S.
    Lin, H. H.
    Chiang, C. C.
    Wang, Y. F.
    Wei, Z. J.
    Ni, Y. C.
    Luo, T. Y.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S511 - S511
  • [15] Feasibility and image quality of dual-isotope SPECT using 18F-FDG and 99mTc-tetrofosmin after acipimox administration
    Kam, BLR
    Valkema, R
    Poldermans, D
    Bax, JJ
    Reijs, AEM
    Rambaldi, R
    Boersma, E
    Rieveld, T
    Roelandt, JRTC
    Krenning, EP
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (02) : 140 - 145
  • [16] Prognostic value of exercise 99mTc-tetrofosmin myocardial perfusion single-photon emission computed tomography for the prediction of cardiac events
    Schinkel, AFL
    Elhendy, A
    Bax, JJ
    Van Domburg, RT
    Bountioukos, M
    Krenning, B
    Roelandt, JRTC
    Poldermans, D
    EUROPEAN HEART JOURNAL, 2003, 24 : 356 - 356
  • [17] Are PTH plasma levels useful for the selection of patients with secondary hyperparathyroidism for preoperative MIBI (99mTc)/123I dual-isotope scintigraphy?
    Balogova, S.
    Sauer, A. -M.
    Perie, S.
    Dudczak, J.
    Nataf, V.
    Pascal, O.
    Kerrou, K.
    Huchet, V.
    Montravers, F.
    St-Guily, J. Lacau
    Talbot, J. -N.
    MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 2010, 34 (07): : 388 - 392
  • [18] Diagnostic Effectiveness of [123I]Ioflupane Single Photon Emission Computed Tomography (SPECT) in Multiple System Atrophy
    Villena-Salinas, Javier
    Jose Ortega-Lozano, Simeon
    Amrani-Raissouni, Tomader
    Aguera, Eduardo
    Caballero-Villarraso, Javier
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (10)
  • [19] Diagnostic value of 123I-betamethyl-p-iodophenyl-pentadecanoic acid (BMIPP) single photon emission computed tomography (SPECT) in patients with chest pain -: Comparison with rest-stress 99mTc-Tetrofosmin SPECT and coronary angiography
    Kawai, Y
    Morita, K
    Nozaki, Y
    Ohkusa, T
    Sakurai, M
    Tamaki, N
    CIRCULATION JOURNAL, 2004, 68 (06) : 547 - 552
  • [20] Image evaluation of different 99mTc/123I ratios for simultaneous dual-isotope myocardial SPECT using D-SPECT cardiac camera
    Shibutani, T.
    Onoguchi, M.
    Yoneyama, H.
    Konishi, T.
    Nakajima, K.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S834 - S834