Sensitivity and Specificity of Dual-Isotope 99mTc-Tetrofosmin and 123I Sodium Iodide Single Photon Emission Computed Tomography (SPECT) in Hyperparathyroidism

被引:10
|
作者
Sommerauer, Michael [1 ]
Graf, Carmen [1 ]
Schaefer, Niklaus [1 ]
Huber, Gerhard [2 ]
Schneider, Paul [3 ]
Wuethrich, Rudolf [4 ]
Schmid, Christoph [5 ]
Steinert, Hans [1 ]
机构
[1] Univ Zurich Hosp, Dept Nucl Med, CH-8091 Zurich, Switzerland
[2] Univ Zurich Hosp, Dept Otorhinolaryngol Head & Neck Surg, CH-8091 Zurich, Switzerland
[3] Univ Zurich Hosp, Dept Gen Visceral & Transplant Surg, CH-8091 Zurich, Switzerland
[4] Univ Zurich Hosp, Div Nephrol, CH-8091 Zurich, Switzerland
[5] Univ Zurich Hosp, Div Endocrinol & Diabetol, CH-8091 Zurich, Switzerland
来源
PLOS ONE | 2015年 / 10卷 / 06期
关键词
PARATHYROID SCINTIGRAPHY; SECONDARY HYPERPARATHYROIDISM; TC-99M-SESTAMIBI SPECT/CT; PHASE TC-99M-SESTAMIBI; C-11-METHIONINE PET/CT; SUBTRACTION SPECT; SESTAMIBI; SURGERY; I-123/TC-99M-SESTAMIBI; EXPLORATIONS;
D O I
10.1371/journal.pone.0129194
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose Despite recommendations for Tc-99m-tetrofosmin dual tracer imaging for hyperparathyroidism in current guidelines, no report was published on dual-isotope Tc-99m-tetrofosmin and I-123 sodium iodide single-photon-emission-computed-tomography (SPECT). We evaluated diagnostic accuracy and the impact of preoperative SPECT on the surgical procedures and disease outcomes. Methods Analysis of 70 consecutive patients with primary hyperparathyroidism and 20 consecutive patients with tertiary hyperparathyroidism. Imaging findings were correlated with surgical results. Concomitant thyroid disease, pre- and postoperative laboratory measurements, histopathological results, type and duration of surgery were assessed. Results In primary hyperparathyroidism, SPECT had a sensitivity of 80% and a positive predictive value of 93% in patient-based analysis. Specificity was 99% in lesion-based analysis. Patients with positive SPECT elicit higher levels of parathyroid hormone and higher weight of resected parathyroids than SPECT-negative patients. Duration of parathyroid surgery was on average, approximately 40 minutes shorter in SPECT-positive than in SPECT-negative patients (89 +/- 46 vs. 129 +/- 41 minutes, p=0.006); 86% of SPECT-positive and 50% of SPECT-negative patients had minimal invasive surgery (p = 0.021). SPECT had lower sensitivity (60%) in patients with tertiary hyperparathyroidism; however, 90% of these patients had multiple lesions and all of these patients had bilateral lesions. Conclusion Dual-isotope SPECT with Tc-99m-tetrofosmin and I-123 sodium iodide has a high diagnostic value in patients with primary hyperparathyroidism and allows for saving of operation time. Higher levels of parathyroid hormone and higher glandular weight facilitated detection of parathyroid lesion. Diagnostic accuracy of preoperative imaging was lower in patients with tertiary hyperparathyroidism.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Comparison of Dual-Isotope 99mTc-Sestamibi/123I-Iodide Subtraction Planar and Dual-Isotope Subtraction SPECT Imaging for Hyperparathyroidism
    Dennis, J. L.
    Bolster, A. A.
    Neilly, J. B.
    Poon, F. W.
    Han, S.
    Gardner, G. G.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S167 - S167
  • [2] Parathyroid detection in secondary hyperparathyroidism with 123I/99mTc-Sestamibi subtraction single photon emission computed tomography
    Neumann, DR
    Esselstyn, CB
    Madera, A
    Wong, CO
    Lieber, M
    JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 1998, 83 (11): : 3867 - 3871
  • [3] Prognosis of patients with a normal stress 99mTc-tetrofosmin myocardial perfusion single photon computed tomography (SPECT).
    Maddahi, J
    Sheybani, A
    Enayati, P
    Woo, M
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 92P - 92P
  • [4] SIMULTANEOUS 99mTc AND 123I DUAL-ISOTOPE BRAIN STRIATAL PHANTOM SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY: VALIDATION OF 99mTc-TRODAT-1 AND 123I-IBZM SIMULTANEOUS DOPAMINE SYSTEM BRAIN IMAGING
    Kao, Pan-Fu
    Wey, Shiaw-Pyng
    Yang, An-Shoei
    KAOHSIUNG JOURNAL OF MEDICAL SCIENCES, 2009, 25 (11): : 601 - 606
  • [5] Repeatability of left ventricular ejection fraction and volume measurement for 99mTc-tetrofosmin gated single photon emission computed tomography (SPECT)
    Thorley, PJ
    Smith, JM
    NUCLEAR MEDICINE COMMUNICATIONS, 2005, 26 (04) : 345 - 349
  • [6] Parathyroid ultrafast 123I/99mTc-tetrofosmin SPECT on a new gamma camera with semiconductor in primary hyperparathyroidism: First clinical validation
    Bailliez, Alban
    Blaire, Tanguy
    Petit, Sylvie
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [7] Physical characteristics of collimators for dual-isotope imaging with 99mTc and 123I
    Tunninen, V.
    Kauppinen, T.
    Eskola, H.
    EMBEC & NBC 2017, 2018, 65 : 245 - 249
  • [8] Dual-Isotope 99mTc-MIBI/123I Parathyroid Scintigraphy in Primary Hyperparathyroidism Comparison of Subtraction SPECT/CT and Pinhole Planar Scan
    Hassler, Stephanie
    Ben-Sellem, Dorra
    Hubele, Fabrice
    Constantinesco, Andre
    Goetz, Christian
    CLINICAL NUCLEAR MEDICINE, 2014, 39 (01) : 32 - 36
  • [9] Dual-isotope SPECT brain imaging using 123I and 99mTc for two independent activation tasks.
    Zubal, G
    Nishizawa, S
    Fujibayashi, Y
    Yonekura, Y
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 200P - 200P
  • [10] Dual-isotope 99mTc-MIBI/123I parathyroid scintigraphy in primary hyperparathyroidism: Comparison of planar scan protocol with subtraction SPECT fused with CT
    Hassler, S.
    Hubele, F.
    Constantinesco, A.
    Goetz, C.
    MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 2011, 35 (03): : 105 - 116