Naturally ventilated double-skin facade with adjustable louvers

被引:27
|
作者
Tao, Yao [1 ,2 ]
Fang, Xiang [1 ,2 ]
Setunge, Sujeeva [1 ]
Tu, Jiyuan [1 ]
Liu, Jingcheng [1 ,2 ]
Shi, Long [1 ]
机构
[1] RMIT Univ, Sch Engn, Melbourne, Vic 3004, Australia
[2] Chongqing Univ Sci & Technol, Big Data Anal & Applicat Res Inst, Chongqing 401331, Peoples R China
基金
澳大利亚研究理事会;
关键词
Natural ventilation; Double-skin facade; Solar  radiation; Renewable energy; CFD simulation; Louver; AIR-FLOW WINDOW; HEAT-TRANSFER; THERMAL PERFORMANCE; ENERGY PERFORMANCE; NUMERICAL-ANALYSIS; VENETIAN BLINDS; BUILDINGS; SOLAR; CLIMATES; SUMMER;
D O I
10.1016/j.solener.2021.07.013
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Naturally ventilated double skin facade (NVDSF) absorbs solar radiation to introduce natural ventilation. It has been proved with significant importance in building energy-saving, and louvers on the NVDSF could be essential in real-life applications for the adjustment of uncomfortable flow. However, the impacts from this practical feature of adjustable louvers on the buoyancy-driven airflow are still not known. Motivated by this, this study addressed the influences of an operable outlet louver on the natural ventilation performance of an NVDSF, with louver angles of 30 degrees-150 degrees under various solar conditions (i.e., solar altitude angles within 10 degrees-80 degrees and direct incident solar radiation within 50-1,000 W/m2) for two types of glazing materials (i.e., regular and low-e glazing). A validated CFD model was used to solve the solar radiation and natural ventilation coupling problem between two semi-transparent facades. The results show that the outlet louvers' influences are significant and should not be ignored in practice. Compared to the no-louver case, upward-opening louvers (louver angles within 30 degrees-67.5 degrees in this study) can promote the ventilation - the optimal louver angle at 45 degrees can enhance the natural airflow by 10-14% for two types of glazings; whereas downward-opening louvers (112.5 degrees-150 degrees) will weaken the natural flow by 6-9% per increment of 10 degrees in louver angles. Empirical models were also developed to quantify the impacts of the typical solar conditions on natural ventilation performance. The obtained power-form functions between the ventilation rates and solar factors (altitude angle and incident radiation) show similarities between NVDSFs and solar chimneys.
引用
收藏
页码:33 / 43
页数:11
相关论文
共 50 条
  • [31] Chimney Effect Assessment of the Double-skin Facade
    QIU Zhong-zhu1
    2.School of Mechanical Engineering
    3.Division of Building Science & Technology
    [J]. 湖南大学学报(自然科学版), 2009, (S1) : 146 - 150
  • [32] Cooling energy performance and thermal characteristics of a naturally ventilated slim double-skin window
    Choi, Haneul
    An, Youngsub
    Kang, Kyungmo
    Yoon, Sunghoon
    Kim, Taeyeon
    [J]. APPLIED THERMAL ENGINEERING, 2019, 160
  • [33] Ventilation performance of a naturally ventilated double skin facade with low-e glazing
    Tao, Yao
    Zhang, Haihua
    Huang, Dongmei
    Fan, Chuangang
    Tu, Jiyuan
    Shi, Long
    [J]. ENERGY, 2021, 229
  • [34] Numerical investigation of fire in the cavity of naturally ventilated double skin facade with venetian blinds
    Huang, Youxian
    Yeboah, Siegfried
    Shao, Jingjing
    [J]. BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2023, 44 (01): : 45 - 61
  • [35] An investigation into the effect of ventilated double-skin facade with venetian blinds: Global simulation and assessment of energy performance
    Gavan, Valentin
    Woloszyn, Monika
    Roux, Jean-Jacques
    Muresan, Cristian
    Safer, Nassim
    [J]. BUILDING SIMULATION 2007, VOLS 1-3, PROCEEDINGS, 2007, : 127 - 133
  • [36] Research on Built Environmental Characteristics of Double-Skin Facade
    Zhang, Weijie
    Li, Yanyan
    Gao, Dongyuan
    Zhao, Qianqian
    [J]. PROCEEDINGS OF THE 8TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOL 3: BUILDING SIMULATION AND INFORMATION MANAGEMENT, 2014, 263 : 435 - 451
  • [37] Experimental evaluation of a naturally ventilated PV double-skin building envelope in real operating conditions
    Gaillard, Leon
    Giroux-Julien, Stephanie
    Menezo, Christophe
    Pabiou, Herve
    [J]. SOLAR ENERGY, 2014, 103 : 223 - 241
  • [38] A thermal similarity model of a curved double-skin facade
    Huang, Yi
    Tao, Yao
    Shi, Long
    Liu, Qinggong
    Wang, Yong
    Tu, Jiyuan
    Gan, Xin
    [J]. SOLAR ENERGY, 2023, 262
  • [39] Experimential investigation of optical properties of double skin facade shading louvers
    [J]. Chen, Youming (ymchen@hnu.com), 1600, Science Press (38):
  • [40] Apron design for protecting double-skin facade fires
    Chow, Nadia C. L.
    Li, S. S.
    Huang, D. X.