Automated calculation of point A coordinates for CT-based high-dose-rate brachytherapy of cervical cancer

被引:1
|
作者
Kang, Hyejoo [1 ]
Padilla, Laura [2 ]
Hasan, Yasmin [3 ]
Ai-Hallaq, Hania [3 ]
机构
[1] Loyola Med, Dept Radiat Oncol, Maywood, IL USA
[2] Virginia Commonwealth Univ Hlth Syst, Dept Radiat Oncol, Richmond, VA USA
[3] Univ Chicago, Dept Radiat & Cellular Oncol, 5758 S Maryland Ave MC 9006, Chicago, IL 60637 USA
关键词
brachytherapy; automation; dose calculation point; image-guided brachytherapy; cervical cancer; FAILURE MODES; EFFICIENCY; CARCINOMA; SOCIETY; RECOMMENDATIONS; VOLUME;
D O I
10.5114/jcb.2017.69397
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The goal is to develop a stand-alone application, which automatically and consistently computes the coordinates of the dose calculation point recommended by the American Brachytherapy Society (i.e., point A) based solely on the implanted applicator geometry for cervical cancer brachytherapy. Material and methods: The application calculates point A coordinates from the source dwell geometries in the computed tomography (CT) scans, and outputs the 3D coordinates in the left and right directions. The algorithm was tested on 34 CT scans of 7 patients treated with high-dose-rate (HDR) brachytherapy using tandem and ovoid applicators. A single experienced user retrospectively and manually inserted point A into each CT scan, whose coordinates were used as the "gold standard" for all comparisons. The gold standard was subtracted from the automatically calculated points, a second manual placement by the same experienced user, and the clinically used point coordinates inserted by multiple planners. Coordinate differences and corresponding variances were compared using nonparametric tests. Results: Automatically calculated, manually placed, and clinically used points agree with the gold standard to < 1 mm, 1 mm, 2 mm, respectively. When compared to the gold standard, the average and standard deviation of the 3D coordinate differences were 0.35 +/- 0.14 mm from automatically calculated points, 0.38 +/- 0.21 mm from the second manual placement, and 0.71 +/- 0.44 mm from the clinically used point coordinates. Both the mean and standard deviations of the 3D coordinate differences were statistically significantly different from the gold standard, when point A was placed by multiple users (p < 0.05) but not when placed repeatedly by a single user or when calculated automatically. There were no statistical differences in doses, which agree to within 1-2% on average for all three groups. Conclusions: The study demonstrates that the automated algorithm calculates point A coordinates consistently, while reducing inter-user variability. Point placement using the algorithm expedites the planning process and minimizes associated potential human errors.
引用
收藏
页码:354 / 358
页数:5
相关论文
共 50 条
  • [31] CT-based adaptive high-dose-rate endorectal brachytherapy in the preoperative treatment of locally advanced rectal cancer: Technical and practical aspects
    Nout, R. A.
    Devic, S.
    Niazi, T.
    Wyse, J.
    Boutros, M.
    Pelsser, V.
    Vuong, T.
    BRACHYTHERAPY, 2016, 15 (04) : 477 - 484
  • [32] Impact of a commercially available model-based dose calculation algorithm on treatment planning of high-dose-rate brachytherapy in patients with cervical cancer
    Abe, Kota
    Kadoya, Noriyuki
    Sato, Shinya
    Hashimoto, Shimpei
    Nakajima, Yujiro
    Miyasaka, Yuya
    Ito, Kengo
    Umezawa, Rei
    Yamamoto, Takaya
    Takahashi, Noriyoshi
    Takeda, Ken
    Jingu, Keiichi
    JOURNAL OF RADIATION RESEARCH, 2018, 59 (02) : 198 - 206
  • [33] An independent dose-to-point calculation program for the verification of high-dose-rate brachytherapy treatment planning
    Cohen, GN
    Amols, HI
    Zaider, M
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (04): : 1251 - 1258
  • [34] Intraoperative ultrasound-based planning can effectively replace postoperative CT-based planning for high-dose-rate brachytherapy for prostate cancer
    Batchelar, Deidre L.
    Chung, Hans T.
    Loblaw, Andrew
    Law, Niki
    Cisecki, Thomas
    Morton, Gerard C.
    BRACHYTHERAPY, 2016, 15 (04) : 399 - 405
  • [35] Workflow and efficiency in MRI-based high-dose-rate brachytherapy for cervical cancer in a high-volume brachytherapy center
    Kim, Hayeon
    Houser, Christopher J.
    Kalash, Ronny
    Maceil, Carly A.
    Palestra, Brett
    Malush, Deborah
    Beriwal, Sushil
    BRACHYTHERAPY, 2018, 17 (05) : 753 - 760
  • [36] HIGH-DOSE-RATE BRACHYTHERAPY
    SPEISER, BL
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 : 116 - 116
  • [37] "In vivo" Dose Measurements in High-Dose-Rate Brachytherapy Treatments for Cervical Cancer: A Project Proposal
    Reynoso Mejia, C. A.
    Buenfil Burgosa, A. E.
    Ruiz Trejo, C.
    Mota Garcia, A.
    Trejo Duran, E.
    Rodriguez Ponce, M.
    Gamboa de Buen, I.
    ELEVENTH MEXICAN SYMPOSIUM ON MEDICAL PHYSICS, 2010, 1310 : 134 - +
  • [38] Workflow efficiency for the treatment planning process in CT-guided high-dose-rate brachytherapy for cervical cancer
    Michaud, Anthony L.
    Benedict, Stanley
    Montemayor, Eliseo
    Hunt, Jon Paul
    Wright, Cari
    Mathai, Mathew
    Mayadev, Jyoti S.
    BRACHYTHERAPY, 2016, 15 (05) : 578 - 583
  • [39] Cumulative Dose With Organ Deformation for Cervical Cancer Treated With Multifraction High-dose-rate Brachytherapy
    Morrow, N. V.
    Ahunbay, E. E.
    Rownd, J. J.
    Li, X.
    Erickson, B.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S794 - S794
  • [40] Comparison of 2 Dose Fractionation Regimens of High-dose-rate Brachytherapy in the Treatment of Cervical Cancer
    Chikuni, S. Msadabwe
    Whitley, A. C.
    Lopez-Araujo, J. J.
    De Los Santos, J. F.
    Burnett, L. O., III
    Spencer, S. A.
    Kim, R. Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S443 - S443