Automated calculation of point A coordinates for CT-based high-dose-rate brachytherapy of cervical cancer

被引:1
|
作者
Kang, Hyejoo [1 ]
Padilla, Laura [2 ]
Hasan, Yasmin [3 ]
Ai-Hallaq, Hania [3 ]
机构
[1] Loyola Med, Dept Radiat Oncol, Maywood, IL USA
[2] Virginia Commonwealth Univ Hlth Syst, Dept Radiat Oncol, Richmond, VA USA
[3] Univ Chicago, Dept Radiat & Cellular Oncol, 5758 S Maryland Ave MC 9006, Chicago, IL 60637 USA
关键词
brachytherapy; automation; dose calculation point; image-guided brachytherapy; cervical cancer; FAILURE MODES; EFFICIENCY; CARCINOMA; SOCIETY; RECOMMENDATIONS; VOLUME;
D O I
10.5114/jcb.2017.69397
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The goal is to develop a stand-alone application, which automatically and consistently computes the coordinates of the dose calculation point recommended by the American Brachytherapy Society (i.e., point A) based solely on the implanted applicator geometry for cervical cancer brachytherapy. Material and methods: The application calculates point A coordinates from the source dwell geometries in the computed tomography (CT) scans, and outputs the 3D coordinates in the left and right directions. The algorithm was tested on 34 CT scans of 7 patients treated with high-dose-rate (HDR) brachytherapy using tandem and ovoid applicators. A single experienced user retrospectively and manually inserted point A into each CT scan, whose coordinates were used as the "gold standard" for all comparisons. The gold standard was subtracted from the automatically calculated points, a second manual placement by the same experienced user, and the clinically used point coordinates inserted by multiple planners. Coordinate differences and corresponding variances were compared using nonparametric tests. Results: Automatically calculated, manually placed, and clinically used points agree with the gold standard to < 1 mm, 1 mm, 2 mm, respectively. When compared to the gold standard, the average and standard deviation of the 3D coordinate differences were 0.35 +/- 0.14 mm from automatically calculated points, 0.38 +/- 0.21 mm from the second manual placement, and 0.71 +/- 0.44 mm from the clinically used point coordinates. Both the mean and standard deviations of the 3D coordinate differences were statistically significantly different from the gold standard, when point A was placed by multiple users (p < 0.05) but not when placed repeatedly by a single user or when calculated automatically. There were no statistical differences in doses, which agree to within 1-2% on average for all three groups. Conclusions: The study demonstrates that the automated algorithm calculates point A coordinates consistently, while reducing inter-user variability. Point placement using the algorithm expedites the planning process and minimizes associated potential human errors.
引用
收藏
页码:354 / 358
页数:5
相关论文
共 50 条
  • [1] single application CT-based interstitial high-dose-rate brachytherapy for cervical cancer
    Yap, E.
    Bacorro, W.
    Ortin, T. Sy
    Jainar, C.
    Dumago, M.
    Bojador, M.
    Cabrera, S.
    Jacomina, L.
    Gonzalez, G.
    Mariano, J.
    Antonio, L.
    Bautista, A.
    Genson, J.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1937 - S1938
  • [2] CONE BEAM CT-BASED THREE-DIMENSIONAL PLANNING IN HIGH-DOSE-RATE BRACHYTHERAPY FOR CERVICAL CANCER
    Al-Halabi, Hani
    Portelance, Lorraine
    Duclos, Marie
    Reniers, Brigitte
    Bahoric, Boris
    Souhami, Luis
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 77 (04): : 1092 - 1097
  • [3] Assessment of the anatomical position of point B and the relationship between point B dose and the dose delivered to pelvic lymph nodes in CT-based high-dose-rate brachytherapy for uterine cervical cancer
    Matsukawa, Hideaki
    Sasaki, Tomonari
    Hirayama, Ryota
    Hirose, Taka-aki
    Fukunaga, Jun-ichi
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2019, 11 (02) : 137 - 145
  • [4] Evaluation of dose to critical structures in CT-based endobronchial high-dose-rate brachytherapy planning
    Kim, Y.
    Colonias, A.
    Parda, D. S.
    Miften, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S637 - S637
  • [5] Benefit of adaptive CT-based treatment planning in high-dose-rate endorectal brachytherapy for rectal cancer
    van den Ende, Roy P. J.
    Rijkmans, Eva C.
    Kerkhof, Ellen M.
    Nout, Remi A.
    Ketelaars, Martijn
    Laman, Mirjam S.
    Marijnen, Corrie A. M.
    van der Heide, Uulke A.
    BRACHYTHERAPY, 2018, 17 (01) : 78 - 85
  • [6] Radiochromic film-based quality assurance for CT-based high-dose-rate brachytherapy
    Asgharizadeh, Saeid
    Bekerat, Hamed
    Syme, Alasdair
    Aldelaijan, Saad
    DeBlois, Francois
    Te Vuong
    Evans, Michael
    Seuntjens, Jan
    Devic, Slobodan
    BRACHYTHERAPY, 2015, 14 (04) : 578 - 585
  • [7] MR- versus CT-based high-dose-rate interstitial brachytherapy for vaginal recurrence of endometrial cancer
    Kamran, Sophia C.
    Manuel, Matthias M.
    Catalano, Paul
    Cho, Linda
    Damato, Antonio L.
    Lee, Larissa J.
    Schmidt, Ehud J.
    Viswanathan, Akila N.
    BRACHYTHERAPY, 2017, 16 (06) : 1159 - 1168
  • [8] 3D CT-based high-dose-rate brachytherapy for cervical cancer: Clinical impact on late rectal bleeding and local control
    Kang, Hyun-Cheol
    Shin, Kyung Hwan
    Park, Sung-Yong
    Kim, Joo-Young
    RADIOTHERAPY AND ONCOLOGY, 2010, 97 (03) : 507 - 513
  • [9] CT-based intra-cavitary high dose rate (HDR) brachytherapy for cervical cancer: planning and QA
    Wang, B.
    Zhu, Y.
    Yeo, I.
    Kwon, A.
    Henson, C.
    MEDICAL PHYSICS, 2007, 34 (06) : 2431 - 2431