Commercial CMOS Pixel Array for Beta and Gamma Radiation Particle Counting.

被引:0
|
作者
Perez, Martin [1 ]
Sofo Haro, Miguel [2 ]
Sidelnik, Ivan [2 ]
Tozzi, Leandro [3 ]
Rondon Brito, David [1 ]
Mora, Carlos [1 ]
Jeronimo Blostein, Juan [2 ]
Gomez Berisso, Mariano [2 ]
Lipovetzky, Jose [1 ,2 ]
机构
[1] CNEA, Buenos Aires, DF, Argentina
[2] Consejo Nacl Invest Cient & Tecn, RA-1033 Buenos Aires, DF, Argentina
[3] INTI, Nilai, Negeri Sembilan, Malaysia
关键词
CMOS Imagers; Radiation; Dosimetry;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We present the response of a Commercial-Off-The-Shelf (COTS) CMOS image sensor to different ionizing particles, with the aim of developing a low cost radiation detector. We first analyze the images obtained by exposing the imagers to Xrays from Fe-55, gamma and beta particles from Cs-137. Then the detector is successfully used to monitor different gamma fluxes produced by the RA6 nuclear research reactor, Argentina, during a startup procedure.
引用
收藏
页码:11 / 16
页数:6
相关论文
共 20 条
  • [1] A particle counting system using the photodetector array of a CMOS image sensor
    Lee, Seung-Jun
    Seo, Yeong-Tai
    Koh, Yul
    Ji, Chang-Hyeon
    Kim, Yong-Kweon
    [J]. JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2012, 22 (09)
  • [2] EFFECT OF ABSORBER POSITION ON COUNTING RATE OF COLLIMATED AND UNCOLLIMATED BETA AND GAMMA RADIATION
    JOHNSTON, F
    WILLARD, JE
    [J]. SCIENCE, 1949, 109 (2819) : 11 - 12
  • [3] Monte Carlo calculation of the sensitivity of a commercial dose calibrator to gamma and beta radiation
    Laedermann, JP
    Valley, JF
    Bulling, S
    Bochud, FO
    [J]. MEDICAL PHYSICS, 2004, 31 (06) : 1614 - 1622
  • [4] CMOS integrated pixel array for low-level radiation detection using 'time compression' parametric amplification
    Durini, Daniel
    Kemna, Armin
    Brockherde, Werner
    Hosticka, Bedrich J.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 568 (01): : 112 - 117
  • [5] CHARACTERIZATION OF COMMERCIAL PROTON EXCHANGE MEMBRANE MATERIALS AFTER EXPOSURE TO BETA AND GAMMA RADIATION
    Thomson, S. N.
    Carson, R.
    Ratnayake, A.
    Muirhead, C.
    Li, H.
    Castillo, I.
    Boniface, H.
    Suppiah, S.
    Robinson, J.
    [J]. FUSION SCIENCE AND TECHNOLOGY, 2015, 67 (02) : 443 - 446
  • [6] Development of a radiation-hardened SRAM with EDAC algorithm for fast readout CMOS pixel sensors for charged particle tracking
    Wei, X.
    Li, B.
    Chen, N.
    Wang, J.
    Zheng, R.
    Gao, W.
    Wei, T.
    Gao, D.
    Hu, Y.
    [J]. JOURNAL OF INSTRUMENTATION, 2014, 9
  • [7] Radiation Effects Testing of the Agilex Commercial off-the-shelf CMOS Field Programmable Gate Array with Protons
    Koga, R.
    Davis, S.
    Yarbrough, A.
    Shanney, J.
    Pham, Kenneth
    Cao, C.
    Pham, Kevin
    Dixon, J.
    [J]. 2023 IEEE RADIATION EFFECTS DATA WORKSHOP, REDW IN CONJUNCTION WITH 2023 NSREC, 2023, : 51 - 55
  • [8] Photon counting readout pixel array in 0.18-μm CMOS technology for on-line gamma-ray imaging of 103Palladium seeds for permanent breast seed implant (PBSI) brachytherapy
    Goldan, A. H.
    Karim, K. S.
    Reznik, A.
    Caldwell, C. B.
    Rowlands, J. A.
    [J]. MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [9] Direct Deposition of Microcolumnar Scintillator on CMOS SSPM Array: Toward a Photon Counting Detector for X-Ray/Gamma Ray Imaging
    Prekas, G.
    Breen, M.
    Sabet, H.
    Bhandari, H.
    Derderian, G.
    Robertson, F., Jr.
    Stapels, C. J.
    Christian, J.
    Cool, S.
    Nagarkar, V. V.
    [J]. APPLICATIONS OF NUCLEAR TECHNIQUES: ELEVENTH INTERNATIONAL CONFERENCE, 2011, 1412
  • [10] Characterization of gamma-ray-induced radiation effects on a commercial CMOS sensor for x-ray small satellites
    Roth, Tyler
    Tammes, Steve
    Kaaret, Philip
    DeRoo, Casey
    Packard, Colin M.
    [J]. JOURNAL OF ASTRONOMICAL TELESCOPES INSTRUMENTS AND SYSTEMS, 2022, 8 (02)