Alternating minimization algorithm for dual energy X-ray CT

被引:0
|
作者
O'Sullivan, JA [1 ]
Benac, J [1 ]
Williamson, JF [1 ]
机构
[1] Washington Univ, Dept Elect & Syst Engn, St Louis, MO 63130 USA
关键词
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
We present a method for obtaining quantitative images from dual energy X-ray CT measurements. We adopt a statistical model for the data and reconstruct images by maximizing the log-likelihood via an alternating minimization (AM) algorithm. Results for simulated data are shown and are compared to a post-processing method.
引用
收藏
页码:579 / 582
页数:4
相关论文
共 50 条
  • [31] Dynamic material decomposition method for MeV dual-energy X-ray CT
    Zhao, Tiao
    Li, Liang
    Chen, Zhiqiang
    APPLIED RADIATION AND ISOTOPES, 2018, 140 : 55 - 62
  • [32] Sensitivity of Dual-Energy CT, Ultrasound, and X-Ray for Pseudogout: A Pilot Study
    Tedeschi, Sara K.
    Solomon, Daniel
    Vanni, Kathleen
    Suh, Dong
    Smith, Stacy
    ARTHRITIS & RHEUMATOLOGY, 2019, 71
  • [33] Learned Alternating Minimization Algorithm for Dual-Domain Sparse-View CT Reconstruction
    Ding, Chi
    Zhang, Qingchao
    Wang, Ge
    Ye, Xiaojing
    Chen, Yunmei
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION, MICCAI 2023, PT X, 2023, 14229 : 173 - 183
  • [34] A study of four minimization approaches for iterative reconstruction in X-ray CT
    De Man, Bruno
    Basu, Samit
    Thibault, Jean-Baptiste
    Hsieh, Jiang
    Fessler, Jeffrey A.
    Bournan, Charles
    Sauer, Ken
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2708 - 2710
  • [35] Effective noise reduction algorithm for material decomposition in dual -energy X-ray inspection
    Lee, Donghyeon
    Jo, HwanHui
    Shim, Soojung
    Kim, Jaehyun
    Oh, Kyungmin
    Lee, Byeongno
    Lee, Namho
    Cho, Seungryong
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 968 (968):
  • [36] A dynamic material discrimination algorithm for dual MV energy X-ray digital radiography
    Li, Liang
    Li, Ruizhe
    Zhang, Siyuan
    Zhao, Tiao
    Chen, Zhiqiang
    APPLIED RADIATION AND ISOTOPES, 2016, 114 : 188 - 195
  • [37] Estimation of liver iron concentration by dual energy CT images: influence of X-ray energy on sensitivity
    Malvarosa, I.
    Massaroni, C.
    Liguori, C.
    Paul, J.
    Zobel, B. Beomonte
    Saccomandi, P.
    Vogl, T. J.
    Silvestri, S.
    Schena, E.
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 5129 - 5132
  • [38] X-Ray CT Energy Spectrum Estimation Algorithm Based on Weighted TV Normalization
    Li Lei
    Wang Lin-yuan
    Xi Xiao-qi
    Han Yu
    Yan Bin
    Bao Shang-lian
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37 (07) : 2230 - 2236
  • [39] Fast algorithm for fluorescent x-ray CT reconstruction
    Yuasa, T
    Takeda, T
    Dilmanian, FA
    Akiba, M
    Hyodo, K
    Akatsuka, T
    Itai, Y
    PROCEEDINGS OF THE 19TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 19, PTS 1-6: MAGNIFICENT MILESTONES AND EMERGING OPPORTUNITIES IN MEDICAL ENGINEERING, 1997, 19 : 863 - 866
  • [40] Experimental Comparison of Proton CT and Dual Energy X-Ray CT in Terms of Relative Stopping Power Accuracy
    Dedes, G.
    Dickmann, J.
    Wesp, P.
    Johnson, R.
    Pankuch, M.
    Bashkirov, V.
    Schulte, R.
    Landry, G.
    Parodi, K.
    MEDICAL PHYSICS, 2019, 46 (06) : E127 - E127