Fate of dissected arch vessels by adventitial inversion technique for acute type A aortic dissection repair

被引:1
|
作者
Takeuchi, Yuriko [1 ]
Suzuki, Ryo [1 ]
Kurazumi, Hiroshi [1 ]
Nawata, Ryosuke [1 ]
Yokoyama, Toshiki [1 ]
Tsubone, Sarii [1 ]
Matsuno, Yutaro [1 ]
Mikamo, Akihito [1 ]
Hamano, Kimikazu [1 ]
机构
[1] Yamaguchi Univ, Grad Sch Med, Dept Surg & Clin Sci, 1-1-1 Minami Kogushi, Ube, Yamaguchi 7558505, Japan
关键词
Aortic dissection; Aortic arch replacement; Arch vessel; Adventitial inversion technique; FALSE LUMEN PATENCY; CAROTID-ARTERY; MANAGEMENT;
D O I
10.1093/icvts/ivac185
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES The adventitial inversion technique is used widely for aortic reconstruction for acute type A aortic dissection, as it easily controls the bleeding at anastomotic sites and closes the patent false lumen. However, this technique for arch vessel reconstruction has not been previously reported. Therefore, we applied the adventitial inversion technique for dissected arch vessel reconstruction to close the patent false lumen. METHODS Among 57 consecutive patients who underwent emergency surgical treatment for acute type A aortic dissection from July 2006 to July 2012, the adventitial inversion technique for the dissected arch vessels was performed in 26 patients (42 arch vessel stumps). The patency and morphologic change of the false lumen of the arch vessels were evaluated using contrast-enhanced computed tomography. RESULTS Overall, 2 hospital deaths were recorded, and the hospital mortality rate was 4%. No postoperative cerebral strokes and reoperations due to bleeding occurred. Follow-up by contrast-enhanced computed tomography was completed in 24 patients (37 stumps) with a mean duration of 99 +/- 35 months. The postoperative closure rate of the false lumen after adventitial inversion was 86%, which was higher than when adventitial inversion was not used. No adverse events including stroke occurred during follow-up period. CONCLUSIONS This technique facilitates the closure of the false lumen of dissected arch vessels and might improve clinical outcomes.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Hybrid Repair of Distal Aortic Arch Dissection Aneurysm With Dissected Kommerell Diverticulum
    Tigkiropoulos, Konstantinos
    Kousidis, Panagiotis
    Lazaridis, Ioannis
    Saratzis, Nikolaos
    VASCULAR AND ENDOVASCULAR SURGERY, 2020, 54 (04) : 375 - 377
  • [22] Residual dissected brachiocephalic artery aneurysm after repair of acute type A aortic dissection
    Yamauchi, Takashi
    Ueda, Hideki
    Kubota, Suguru
    Hasegawa, Kosei
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2017, 24 (02) : 310 - 311
  • [23] Concomitant Reconstruction of Arch Vessels during Repair of Aortic Dissection
    Micovic, Slobodan
    Nezic, Dusko
    Vukovic, Petar
    Jovanovic, Marko
    Lozuk, Branko
    Jagodic, Sinisa
    Djukanovic, Bosko
    TEXAS HEART INSTITUTE JOURNAL, 2014, 41 (04) : 421 - 424
  • [24] Fate of descending aorta after acute type A aortic dissection repair
    Kim, Wan Kee
    Kim, Tae-Hoon
    Lee, Ha
    Song, Suk-Won
    Yoo, Kyung-Jong
    JOURNAL OF THORACIC DISEASE, 2023, 15 (11) : 5942 - +
  • [25] The fate of the distal aorta after repair of acute type A aortic dissection
    Halstead, James C.
    Meier, Matthias
    Etz, Christian
    Spielvogel, David
    Bodian, Carol
    Wurm, Michael
    Shahani, Rohit
    Griepp, Randall B.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2007, 133 (01): : 127 - U102
  • [26] A graft inversion technique for retrograde type A aortic dissection after thoracic endovascular repair for type B aortic dissection
    Wenbin Hu
    Yiran Zhang
    Lei Guo
    Jingya Fan
    Yuan Lu
    Liang Ma
    Journal of Cardiothoracic Surgery, 14
  • [27] Sandwich Technique for Endovascular Repair of Acute Type A Aortic Dissection
    Gao, Feng
    Zeng, Qian
    Lin, Fangming
    Ge, Xiaohu
    JOURNAL OF ENDOVASCULAR THERAPY, 2017, 24 (05) : 647 - 653
  • [28] A graft inversion technique for retrograde type A aortic dissection after thoracic endovascular repair for type B aortic dissection
    Hu, Wenbin
    Zhang, Yiran
    Guo, Lei
    Fan, Jingya
    Lu, Yuan
    Ma, Liang
    JOURNAL OF CARDIOTHORACIC SURGERY, 2019, 14 (1)
  • [29] Fate of the Dissected Thoraco-Abdominal Aorta Distal to TEVAR (Thoracic Endovascular Aortic Repair) for Complicated Acute and Subacute Type B Aortic Dissection
    Nassib, Jowan
    Hireche, Kheira
    Ozdemir, Baris Ata
    Alric, Pierre
    Canaud, Ludovic
    JOURNAL OF ENDOVASCULAR THERAPY, 2022, 29 (05) : 773 - 779
  • [30] Frozen Elephant Trunk Repair for Acute Type A Dissection in Right Aortic Arch
    Calderone, Alexander
    Chauvette, Vincent
    Demers, Philippe
    Lamarche, Yoan
    ANNALS OF THORACIC SURGERY, 2022, 113 (06): : E429 - E431