Periprosthetic fractures around cementless hydroxyapatite-coated femoral stems

被引:23
|
作者
van der Wal, BCH
Vischjager, M
Grimm, B
Heyligers, IC
Tonino, AJ
机构
[1] Atrium Med Ctr, Dept Orthopaed Surg, NL-6401 CX Heerlen, Netherlands
[2] Leyenburg Hosp, Dept Orthopaed Surg, NL-2545 CH The Hague, Netherlands
关键词
D O I
10.1007/s00264-005-0657-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We studied 14 periprosthetic femoral fractures out of a series of 619 hydroxyapatite coated hip implants and compared the outcome to published treatment algorithms using the Vancouver classification. There were five type A fractures, six B1, two B2, and one type B3 fracture. All but one type A fractures were treated conservatively. Compared with the Vancouver classification, we observed a different fracture type in the type B fractures. No fractures at the tip of the stem were seen, as in cemented implants. Three B1 fractures were treated operatively due to fracture displacement, and three were treated conservatively. The B2 and B3 fractures were managed with long, uncemented, revision stems because of a disrupted bone-prosthesis interface. All fractures healed well. This study confirms that the modified algorithm of management of periprosthetic fractures, using the Vancouver classification, is a simple, reproducible, classification system for uncemented prostheses. Conservative treatment is a valid option if the implant is stable whilst surgical intervention is mandatory if the implant is loose.
引用
收藏
页码:235 / 240
页数:6
相关论文
共 50 条
  • [21] Hydroxyapatite-coated femoral stems - A matched-pair analysis of coated and uncoated implants
    Rothman, RH
    Hozack, WJ
    Ranawat, A
    Moriarty, L
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (03): : 319 - 324
  • [22] Subsidence and perioperative periprosthetic fractures using collarless hydroxyapatite-coated stem for displaced femoral neck fractures according to Dorr type
    Song, Joo-Hyoun
    Jo, Woo-Lam
    Lee, Kee-Haeng
    Cho, Yoon-Joo
    Park, Joonyoung
    Oh, Seungbae
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY, 2019, 27 (03)
  • [23] Periprosthetic bone density around fully hydroxyapatite coated femoral stem
    Trevisan, C
    Bigoni, M
    Randelli, G
    Marinoni, EC
    Peretti, G
    Ortolani, S
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1997, (340) : 109 - 117
  • [24] HYDROXYAPATITE-COATED PROXIMAL INGROWTH FEMORAL STEMS - A MATCHED-PAIR CONTROL STUDY
    MCPHERSON, EJ
    DORR, LD
    GRUEN, TA
    SABERI, MT
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1995, (315) : 223 - 230
  • [25] Radiographic Analysis of Bone Remodeling around Hydroxyapatite Coated Femoral Stems
    Marinescu, Rodica
    Laptoiu, Dan
    Botezatu, Iozefina
    [J]. BIOCERAMICS, VOL 25, 2014, 587 : 436 - 441
  • [26] Cementless hemispheric hydroxyapatite-coated sockets for acetabular revision
    Geerdink, Carel H.
    Schaafsma, Jelle
    Meyers, Will G. M.
    Grimm, Bernd
    Tonino, Alphons J.
    [J]. JOURNAL OF ARTHROPLASTY, 2007, 22 (03): : 369 - 376
  • [27] Intraoperative type 1 proximal femoral fractures - Influence on the stability of hydroxyapatite-coated femoral components
    Falez, F
    Santori, N
    Panegrossi, G
    [J]. JOURNAL OF ARTHROPLASTY, 1998, 13 (06): : 653 - 659
  • [28] Mid-term outcome of a modular, cementless, proximally hydroxyapatite-coated, anatomic femoral stem
    Cossetto, David J.
    Goudar, Anil
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY, 2012, 20 (03): : 322 - 326
  • [29] Treatment of periprosthetic femoral fractures with modular stems
    Daniel Hernandez-Vaquero
    Jesus Fernandez-Lombardia
    Jimena Llorens de los Rios
    Ivan Perez-Coto
    Susana Iglesias-Fernandez
    [J]. International Orthopaedics, 2015, 39 : 1933 - 1938
  • [30] Treatment of periprosthetic femoral fractures with modular stems
    Hernandez-Vaquero, Daniel
    Fernandez-Lombardia, Jesus
    Llorens de los Rios, Jimena
    Perez-Coto, Ivan
    Iglesias-Fernandez, Susana
    [J]. INTERNATIONAL ORTHOPAEDICS, 2015, 39 (10) : 1933 - 1938