Peri-implant bone response to orthodontic loading: Part 1. A histomorphometric study of the effects of implant surface design

被引:29
|
作者
Oyonarte, R [1 ]
Pilliar, RM [1 ]
Deporter, D [1 ]
Woodside, DG [1 ]
机构
[1] Univ Toronto, Fac Dent, Toronto, ON M5G 1G6, Canada
基金
加拿大健康研究院;
关键词
D O I
10.1016/j.ajodo.2004.02.023
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: Bone response to orthodontic loading was compared histomorphometrically around 2 different types of osseointegrated implants (porous surfaced and machined threaded) to determine their suitability for orthodontic anchorage. Methods: Five beagles each received 3 implants of each design in contralateral mandibular locations. After a 6-week initial healing period, abutments were placed, and, 1 week later, the 2 mesial implants on each side were orthodontically loaded for 22 weeks. All implants remained osseointegrated throughout orthodontic loading except for 1 threaded implant that loosened. Light miscroscopy and back-scattered scanning electron microscopy were used to compare responses around the 2 implant designs. Results: Porous-surfaced implants had higher marginal bone levels (P +/- .025) and less relative implant displacement than threaded implants. Conclusions: Differences in implant surface design can lead to differences in peri-implant bone height and bone-to-implant contact. Porous-surfaced implants might be successful as orthodontic anchorage units.
引用
收藏
页码:173 / 181
页数:9
相关论文
共 50 条
  • [21] Electrical field effect on peri-implant osteogenesis: A histologic and histomorphometric study
    Giannunzio, Graciela Ana
    Speerli, Rodolfo Carlos
    Guglielmotti, Maria Beatriz
    IMPLANT DENTISTRY, 2008, 17 (01) : 118 - 126
  • [22] A histomorphometric study of peri-implant bone healing under experimental anemia and polycythemia in rats.
    Gorustovich, A. A.
    Giglio, M. J.
    Guglielmotti, M. B.
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : B274 - B274
  • [23] Immediate implant placement following 1-year treatment with oral versus intravenous bisphosphonates: a histomorphometric canine study on peri-implant bone
    Khojasteh, Arash
    Dehghan, Mohammad Mehdi
    Nazeman, Pantea
    CLINICAL ORAL INVESTIGATIONS, 2019, 23 (04) : 1803 - 1809
  • [24] Immediate implant placement following 1-year treatment with oral versus intravenous bisphosphonates: a histomorphometric canine study on peri-implant bone
    Arash Khojasteh
    Mohammad Mehdi Dehghan
    Pantea Nazeman
    Clinical Oral Investigations, 2019, 23 : 1803 - 1809
  • [25] Effects of Condensation on Peri-implant Bone Density and Remodeling
    Wang, L.
    Wu, Y.
    Perez, K. C.
    Hyman, S.
    Brunski, J. B.
    Tulu, U.
    Bao, C.
    Salmon, B.
    Helms, J. A.
    JOURNAL OF DENTAL RESEARCH, 2017, 96 (04) : 406 - 413
  • [26] Anabolic effects of bisphosphonates on peri-implant bone stock
    von Knoch, Fabian
    Eckhardt, Christina
    Alabre, Claude I.
    Schneider, Erich
    Rubash, Harry E.
    Shanbhag, Arun S.
    BIOMATERIALS, 2007, 28 (24) : 3549 - 3559
  • [27] Effect of Implant Surface Properties on Peri-Implant Bone Healing: Implant Stability and Microcomputed Tomographic Analysis
    Al-Moaber, Samar H.
    Al-Hamdan, Khalid
    Junker, Rudiger
    Jansen, John A.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2012, 27 (01) : 77 - 83
  • [28] Titanium implant with nanostructured zirconia surface promotes maturation of peri-implant bone in osseointegration
    Dusad, Anand
    Chakkalakal, Dennis A.
    Namavar, Fereydoon
    Haider, Hani
    Hanisch, Brock
    Duryee, Michael J.
    Diaz, April
    Rensch, Adam
    Zhang, Yijia
    Hess, Ryan
    Thiele, Geoffrey M.
    Fehringer, Edward V.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2013, 227 (H5) : 510 - 522
  • [29] Changes in the fractal dimension of peri-implant trabecular bone after loading: a retrospective study
    Mu, Teh-Jing
    Lee, Dong-Won
    Park, Kwang-Ho
    Moon, Ik-Sang
    JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2013, 43 (05): : 209 - 214
  • [30] Numerical simulation of the effect of time-to-loading on peri-implant bone
    Akca, Kivanc
    Eer, Atilim
    Canay, Senay
    MEDICAL ENGINEERING & PHYSICS, 2010, 32 (01) : 7 - 13