The Influence of Acute Pulmonary Hypertension on Cardiac Output Measurements: Calibrated Pulse Contour Analysis, Transpulmonary and Pulmonary Artery Thermodilution Against a Modified Fick Method in an Animal Model

被引:7
|
作者
Kutter, Annette P. N. [1 ]
Mosing, Martina [1 ]
Hartnack, Sonja [2 ]
Raszplewicz, Joanna [1 ]
Renggli, Martina [1 ]
Mauch, Jacqueline Y. [3 ]
Hofer, Christoph K. [4 ]
机构
[1] Univ Zurich, Vetsuisse Fac, Equine Dept, Sect Anesthesiol, CH-8057 Zurich, Switzerland
[2] Univ Zurich, Vetsuisse Fac, Epidemiol Sect, CH-8057 Zurich, Switzerland
[3] Kantonsspital Luzern, Dept Anesthesiol, Luzern, Switzerland
[4] Triemli City Hosp, Inst Anesthesiol & Intens Care Med, Zurich, Switzerland
来源
ANESTHESIA AND ANALGESIA | 2015年 / 121卷 / 01期
关键词
RELIABILITY; PRECISION; ACCURACY; MONITORS; ABILITY;
D O I
10.1213/ANE.0000000000000655
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
BACKGROUND: In critically ill patients with significant pulmonary hypertension (PH), close perioperative cardiovascular monitoring is mandatory, considering the increased morbidity and mortality in this patient group. Although the pulmonary artery catheter is still the standard for the diagnosis of PH, its use to monitor cardiac output (CO) in patients with PH is decreasing as a result of increased morbidity and possible influence of tricuspid regurgitation on the measurements. However, continuous CO measurement methods have never been evaluated under PH regarding their agreement and trending ability. In this study, we evaluated the influence of acute PH and different CO states on transpulmonary thermodilution (TPTD) and calibrated pulse contour analysis (PiCCO; both assessed with PiCCO plus (TM)), intermittent pulmonary artery thermodilution (PATD), and continuous thermodilution (CCO) compared with a modified Fick method (FICK) in an animal model. METHODS: Nine healthy pigs were studied under anesthesia. PH of 25 and 40 mm Hg (by administration of the thromboxane analog U46619), CO decreases, and CO increases were induced to test the different CO measurement techniques over a broad range of hemodynamic situations. Before each step, a new baseline data set was collected. CO values were compared using Bland-Altman analysis; trending abilities were assessed via concordance and polar plot analysis. The influence of pulmonary pressure on CO measurements was analyzed using linear mixed models. RESULTS: A mean bias of -0.26 L/min with prediction intervals of -0.88 to 1.4 L/min was measured between TPTD and FICK. Their concordance rate was 100% (94%-100% confidence interval), and the mean polar angle -3 degrees with radial limits of agreement of +/-28 degrees indicated good trending abilities. PATD compared with FICK also showed good trending ability. Comparisons of PiCCO and CCO versus FICK revealed low agreement and poor trending results with concordance rates of 84% (71%-93%) and 88% (74%-95%), mean polar angles from -17 degrees and -19 degrees, and radial limits of agreement of +/-45 degrees and 40 degrees. Pulmonary pressures influenced only the difference between FICK and PiCCO, as assessed by linear mixed models. CONCLUSIONS: TPTD compared with FICK was able to track all changes induced during the study period, including those by PH. It yielded better agreement than PATD both compared with FICK. PiCCO and CCO were not mapping all changes correctly, and when used clinically in unstable patients, regular controls with intermittent techniques are required. Acute pharmacologically induced PH did influence the difference between FICK and PiCCO.
引用
收藏
页码:99 / 107
页数:9
相关论文
共 40 条
  • [21] Validation of Cardiac Output Measurement by Ultrasound Dilution Technique With Pulmonary Artery Thermodilution in a Pediatric Animal Model
    Edward Darling
    Naveen Thuramalla
    Bruce Searles
    Pediatric Cardiology, 2011, 32 : 585 - 589
  • [22] Validation of Cardiac Output Measurement by Ultrasound Dilution Technique With Pulmonary Artery Thermodilution in a Pediatric Animal Model
    Darling, Edward
    Thuramalla, Naveen
    Searles, Bruce
    PEDIATRIC CARDIOLOGY, 2011, 32 (05) : 585 - 589
  • [23] Comparison of pulmonary artery and aortic transpulmonary thermodilution for monitoring of cardiac output in patients with severe heart failure: Validation of a novel method
    Friesecke, Sigrun
    Heinrich, Annegret
    Abel, Peter
    Felix, Stephan B.
    CRITICAL CARE MEDICINE, 2009, 37 (01) : 119 - 123
  • [24] Assessment of transpulmonary thermodilution, ultrasound dilution, and esophageal Doppler against direct pulmonary artery flow for cardiac output monitoring in anesthetized cats
    Liao, Pen-Ting
    Tillson, Michael
    Clark-Price, Stuart
    Kuo, Kendon
    Gerken, Katherine
    Claret, Aina
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2025, 86 (03)
  • [25] Continuous cardiac output during off-pump coronary artery bypass surgery:: pulse-contour analyses vs pulmonary artery thermodilution
    Halvorsen, P. S.
    Sokolovl, A.
    Cvancarova, M.
    Hol, P. K.
    Lundblad, R.
    Tonnessen, T. I.
    BRITISH JOURNAL OF ANAESTHESIA, 2007, 99 (04) : 484 - 492
  • [26] Disagreement between pulse contour analysis and transpulmonary thermodilution for cardiac output monitoring after routine therapeutic interventions in ICU patients with acute circulatory failure
    Muller, Laurent
    Candela, Damien
    Nyonzyma, Lambert
    Mattatia, Laurent
    Suehs, Carey
    Fabbro-Peray, Pascale
    Louart, Guillaume
    de La Coussaye, Jean E.
    Jaber, Samir
    Leone, Marc
    Lefrant, Jean-Y
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2011, 28 (09) : 664 - 669
  • [27] Validation of cardiac output monitoring based on uncalibrated pulse contour analysis vs transpulmonary thermodilution during off-pump coronary artery bypass grafting
    Smetkin, A. A.
    Hussain, A.
    Kuzkov, V. V.
    Bjertnaes, L. J.
    Kirov, M. Y.
    BRITISH JOURNAL OF ANAESTHESIA, 2014, 112 (06) : 1024 - 1031
  • [28] Cross-comparisons of trending accuracies of continuous cardiac-output measurements: pulse contour analysis, bioreactance, and pulmonary-artery catheter
    Lamia, Bouchra
    Kim, Hyung Kook
    Severyn, Donald A.
    Pinsky, Michael R.
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2018, 32 (01) : 33 - 43
  • [29] Cross-comparisons of trending accuracies of continuous cardiac-output measurements: pulse contour analysis, bioreactance, and pulmonary-artery catheter
    Bouchra Lamia
    Hyung Kook Kim
    Donald A. Severyn
    Michael R. Pinsky
    Journal of Clinical Monitoring and Computing, 2018, 32 : 33 - 43
  • [30] Continuous cardiac output measurement by un-calibrated pulse wave analysis and pulmonary artery catheter in patients with septic shock
    Michael T. Ganter
    Jamal A. Alhashemi
    Adel M. Al-Shabasy
    Ursina M. Schmid
    Peter Schott
    Sanaa A. Shalabi
    Ahmed M. Badri
    Sonja Hartnack
    Christoph K. Hofer
    Journal of Clinical Monitoring and Computing, 2016, 30 : 13 - 22