The Utilization of Metal Augments Allows Better Biomechanical Reconstruction of the Hip in Revision Total Hip Arthroplasty With Severe Acetabular Defects: A Comparative Study

被引:15
|
作者
Zhou, Baochun [1 ]
Zhou, Yixin [1 ]
Yang, Dejin [1 ]
Tang, Hao [1 ]
Shao, Hongyi [1 ]
Huang, Yong [1 ]
机构
[1] Peking Univ, Dept Orthopaed Surg, Beijing Jishuitan Hosp, Clin Coll 4, 31 Xinjiekou East St, Beijing 100035, Peoples R China
来源
JOURNAL OF ARTHROPLASTY | 2018年 / 33卷 / 12期
关键词
revision total hip arthroplasty; biomechanical reconstruction; augment; jumbo cup; center of rotation; head-cup difference; ABDUCTOR MUSCLE STRENGTH; LEG-LENGTH DISCREPANCY; JUMBO CUPS; FOLLOW-UP; PROTRUSIO-ACETABULI; SUPERIOR PLACEMENT; CENTER ELEVATION; FEMORAL OFFSET; IIIA DEFECTS; BONE LOSS;
D O I
10.1016/j.arth.2018.08.027
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Reconstructing the normal hip biomechanics is important for a successful revision total hip arthroplasty (THA). Little is known about whether using metal augments in revision THA is biomechanically superior to traditional techniques. Methods: A retrospective review was conducted on 74 consecutive THAs revised using metal augments with a cementless hemispherical cup and 77 consecutive THAs revised using the jumbo cup, all with a minimum 2-year follow-up. Biomechanical parameters were measured before and immediately after the revision. Radiological and clinical outcomes at follow-ups were also evaluated. Results: The metal augment group had a reconstructed center of rotation (COR) that was 6.5 mm closer to the anatomic COR in height (P < .001), had 3.6 m smaller cup size (P < .001), and had 5.7 mm less head-cup difference (P < .001). Moreover, there was a reconstructed COR that was much closer to the anatomic COR (vertical distance: 1.8 vs 14.1 mm, P < .001; horizontal distance: -2.1 vs 7.9 mm, P = .013), had 4.1 mm greater femoral offset (P = .006), and had 8 mm less leg length discrepancy (P = .035) in the subgroup of Paprosky type III bone defects when compared to the jumbo cup group. All cup-augment constructs were radiologically stable with a higher mean postoperative Harris Hip Score (P = .012). One jumbo cup was radiologically unstable. Conclusion: In revision THA, utilizing metal augments helps to restore the COR position more precisely, avoid using a larger cup, reduce head-cup difference, rebuild femoral offset, and decrease leg length discrepancy, particularly with Paprosky type III bone defects. Moreover, it provides satisfactory radiological and clinical outcomes in the short term. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:3724 / 3733
页数:10
相关论文
共 50 条
  • [41] The patient-specific Triflange acetabular implant for revision total hip arthroplasty in patients with severe acetabular defects PLANNING, IMPLANTATION, AND RESULTS
    Berend, M. E.
    Berend, K. R.
    Lombardi, A. V.
    Cates, H.
    Faris, P.
    BONE & JOINT JOURNAL, 2018, 100B (01): : 50 - 54
  • [42] Aortic thrombosis after acetabular revision of a total hip arthroplasty
    Leung, AG
    Cabanela, ME
    JOURNAL OF ARTHROPLASTY, 1998, 13 (08): : 961 - 965
  • [43] ACETABULAR PREPARATION IN CEMENTLESS REVISION TOTAL HIP-ARTHROPLASTY
    MCGANN, WA
    WELCH, RB
    PICETTI, GD
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1988, (235) : 35 - 46
  • [44] Constrained acetabular components in complex revision total hip arthroplasty
    McCarthy, JC
    Lee, J
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (441) : 210 - 215
  • [45] Comparative Survival of Contemporary Cementless Acetabular Components Following Revision Total Hip Arthroplasty
    Wilson, Jacob M.
    Maradit-Kremers, Hilal
    Abdel, Matthew P.
    Berry, Daniel J.
    Mabry, Tad M.
    Pagnano, Mark W.
    Perry, Kevin I.
    Sierra, Rafael J.
    Taunton, Michael J.
    Trousdale, Robert T.
    Lewallen, David G.
    JOURNAL OF ARTHROPLASTY, 2023, 38 (07): : S194 - S200
  • [46] Reconstruction of major column defects and pelvic discontinuity in revision total hip arthroplasty
    Stiehl, JB
    Saluja, R
    Diener, T
    JOURNAL OF ARTHROPLASTY, 2000, 15 (07): : 849 - 857
  • [47] Management of Acetabular Bone Loss in Revision Total Hip Arthroplasty
    Deirmengian, Gregory K.
    Zmistowski, Benjamin
    O'Neil, Joseph T.
    Hozack, William J.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (19): : 1842 - 1852
  • [48] Biomechanical effect of metal augment and bone graft on cup stability for acetabular reconstruction of total hip arthroplasty in hip dysplasia: a finite element analysis
    Yuzhu Wang
    Mincong Wang
    Chengguo Li
    Yoshihiro Nakamura
    Liwei Deng
    Go Yamako
    Etsuo Chosa
    Chenglong Pan
    BMC Musculoskeletal Disorders, 23
  • [49] CORR InsightsA®: Complications Are Not Increased With Acetabular Revision of Metal-on-metal Total Hip Arthroplasty
    Jones, Stephen A.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2016, 474 (10) : 2143 - 2144
  • [50] Biomechanical effect of metal augment and bone graft on cup stability for acetabular reconstruction of total hip arthroplasty in hip dysplasia: a finite element analysis
    Wang, Yuzhu
    Wang, Mincong
    Li, Chengguo
    Nakamura, Yoshihiro
    Deng, Liwei
    Yamako, Go
    Chosa, Etsuo
    Pan, Chenglong
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)