Biomechanical Evaluation of Two-Part Surgical Neck Fractures of the Humerus Fixed by an Angular Stable Locked Intramedullary Nail

被引:31
|
作者
Horn, Joachim [1 ]
Gueorguiev, Boyko [2 ]
Brianza, Stefano [2 ]
Steen, Harald [1 ]
Schwieger, Karsten [2 ]
机构
[1] Univ Hosp, Rikshosp, Dept Orthopaed, NO-0027 Oslo, Norway
[2] AO Res Inst, Davos, Switzerland
关键词
intramedullary nail; angular stability; locking screws; humerus; fracture; surgical neck; biomechanical; PROXIMAL HUMERUS; INTERNAL-FIXATION; LOCKING PLATE; PERCUTANEOUS FIXATION; 4-PART FRACTURES; OPEN REDUCTION; IMPLANTS; OSTEOSYNTHESIS; EPIDEMIOLOGY; 3-PART;
D O I
10.1097/BOT.0b013e3181ffdf9a
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: The aim of the current study was to see how different interlocking mechanisms would affect construct stability and overall failure in the treatment of two-part surgical neck fractures in the proximal humerus in vitro. Methods: Left and right bones of eight pairs of fresh-frozen human cadaveric humeri were assigned to either a group with conventional or a group with angular stable distal interlocking. The different experimental interlocking mechanisms were used in a surgical neck fracture model of the humerus (Orthopaedic Trauma Association 11-A3) stabilized by a proximal humeral nail. The following variables were evaluated by biomechanical tests: hysteresis width in bending and torsion, stiffness, and fracture gap movement during cyclic axial loading until failure and the overall failure mechanism of the construct. Results: The angular stable group showed significantly less motion in initial bending and torsion and higher bending stiffness throughout the complete deformation cycle compared with the conventional interlocked group. Fracture gap movement was significantly less in the angular stable group. Higher stability was mainly observed in the early phase of the applied loading pattern; however, ultimate failure was not related to distal interlocking but occurred in the proximal fragment in both groups. Conclusions: An experimental angular stable distal interlocking system of proximal humeral nails shows higher construct stability in the early phase of fracture fixation in vitro. In terms of overall failure, loss of fixation in the proximal fragment was crucial and not different between groups.
引用
收藏
页码:406 / 413
页数:8
相关论文
共 36 条
  • [21] A comparative study of locking plate combined with minimally invasive plate osteosynthesis and intramedullary nail fixation in the treatment of Neer classification of two-part and three-part fractures of the proximal humerus
    Zhu, Xiang
    Ding, Chen
    Zhu, Ya
    Nian, Shensheng
    Tang, Hao
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2024, 34 (05): : 2743 - 2749
  • [22] Two-part surgical neck fractures of the humerus: Mechanical analysis of the fixation with four Shanz-type threaded pins in four different assemblies
    Durigan, A
    Barbieri, CH
    Mazzer, N
    Shimano, AC
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2005, 14 (01) : 96 - 102
  • [23] Biomechanical and clinical evaluation of minimal invasive plate osteosynthesis for two-part clavicle shaft fractures
    Antonia Schlüßler
    Manuel Fehrenbacher
    Richard Frank Richter
    Eric Tille
    Achim Biewener
    Jörg Nowotny
    BMC Musculoskeletal Disorders, 24
  • [24] Biomechanical and clinical evaluation of minimal invasive plate osteosynthesis for two-part clavicle shaft fractures
    Schluessler, Antonia
    Fehrenbacher, Manuel
    Richter, Richard Frank
    Tille, Eric
    Biewener, Achim
    Nowotny, Joerg
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [25] Operative Treatment of 2-Part Surgical Neck Fracture of the Humerus: Intramedullary Nail Versus Locking Compression Plate With Technical Consideration
    Lee, Wonyong
    Park, Jun-Young
    Chun, Yong-Min
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2017, 31 (09) : E270 - E274
  • [26] Fixed-angle locked plating of two-, three-, and four-part proximal humerus fractures
    Badman, Brian L.
    Mighell, Mark
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2008, 16 (05) : 294 - +
  • [27] Biomechanical evaluation of two intramedullary nailing techniques with different locking options in a three-part fracture proximal humerus model
    Rothstock, Stephan
    Plecko, Michael
    Kloub, Martin
    Schiuma, Damiano
    Windolf, Markus
    Gueorguiev, Boyko
    CLINICAL BIOMECHANICS, 2012, 27 (07) : 686 - 691
  • [28] Biomechanical evaluation of two modified intramedullary fixation system for treating unstable femoral neck fractures: A finite element analysis
    Huang, Qiang
    Zhang, CongMing
    Bai, HuanAn
    Wang, Qian
    Li, Zhong
    Lu, Yao
    Ma, Teng
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [29] Biomechanical comparison of fixation of two-part osteoporotic neck fracture of the proximal humerus using uni-planar and multi-planar Kirschner wire
    Esen, Erdinc
    Dogramaci, Yunus
    Komurcu, Mahmut
    Kanatli, Ulunay
    Bolukbasi, Selcuk
    Atahan, Ali Osman
    EKLEM HASTALIKLARI VE CERRAHISI-JOINT DISEASES AND RELATED SURGERY, 2009, 20 (02): : 114 - 118
  • [30] Operative treatment of 2-part surgical neck type fractures of the proximal humerus in the elderly: Cement augmented locking plate PHILOS™ vs. proximal humerus nail multiloc®
    Helfen, Tobias
    Siebenbuerger, Georg
    Fleischhacker, Evi
    Gleich, Johannes
    Boecker, Wolfgang
    Ockert, Ben
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2020, 51 (10): : 2245 - 2252