Investigating water transport in MDF and OSB using a gantry-based X-ray CT scanning system

被引:13
|
作者
Li, Wanzhao [1 ,2 ]
Van den Bulcke, Jan [1 ]
De Schryver, Thomas [3 ]
Van Acker, Joris [1 ]
机构
[1] Ghent Univ UGCT, Fac Biosci Engn, Dept Forest & Water Management, Lab Wood Technol, Coupure Links 653, B-9000 Ghent, Belgium
[2] Nanjing Forestry Univ, Coll Mat Sci & Engn, Longpan Rd 159, Nanjing, Jiangsu, Peoples R China
[3] Univ Ghent, Ctr Xray Tomog UGCT, Dept Phys & Astron, Proeftuinstr 86, B-9000 Ghent, Belgium
关键词
MEDIUM DENSITY FIBERBOARD; MECHANICAL-PROPERTIES; WOOD; ABSORPTION; RESISTANCE;
D O I
10.1007/s00226-016-0855-8
中图分类号
S7 [林业];
学科分类号
0829 ; 0907 ;
摘要
Both medium density fiberboard (MDF) and oriented strand board (OSB) are important engineered wood products. Water uptake can decrease their physical and mechanical properties as well as induce fungal decay. It is therefore essential to understand the water transport behavior in these products in detail. In this research, a state-of-the-art gantry-based X-ray CT scanner was used to investigate the water transport and the internal microstructure of the specimens from different types of MDF and OSB during water uptake. The results show that water, obviously, is mainly absorbed from the sides of all specimens during immersion testing. Water can reach the interior of the small specimens within 1 h through large fibers and strands. Although water movement through voids is slow, high water content can be reached when these voids are filled; for example, moisture content of more than 100 % is found in MDF. A compact structure can effectively decrease water accumulation in voids. Furthermore, the presence of a water-resistant adhesive, a water-repellent additive and acetylated fibers clearly influences water transport behavior in wood fibers and voids, increasing water resistance and improve structural stability of MDF. Moisture dynamics of OSB are different, among others influenced by orientation of the strands: grain direction perpendicular to the water uptake direction can protect OSB from water penetration. Furthermore, strands covered with resin have a good water resistance.
引用
收藏
页码:1197 / 1211
页数:15
相关论文
共 50 条
  • [31] Network based CAD system for lung cancer screening by X-ray CT
    Emoto, H
    Yamamoto, S
    Matsumoto, M
    Matsumoto, T
    Tateno, Y
    Iinuma, T
    CARS 2002: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2002, : 723 - 728
  • [32] Advanced X-ray CT scanning can boost tree ring research for earth system sciences
    Van den Bulcke, Jan
    Boone, Marijn A.
    Dhaene, Jelle
    Van Loo, Denis
    Van Hoorebeke, Luc
    Boone, Matthieu N.
    Wyffels, Francis
    Beeckman, Hans
    Van Acker, Joris
    De Mil, Tom
    ANNALS OF BOTANY, 2019, 124 (05) : 837 - 847
  • [33] Development and optimization of a backscatter X-ray detection system based on pencil beam scanning
    Park, Jaehyun
    An, Geunyoung
    Song, Gyohyeok
    Kim, Wonku
    Kim, Junhyeok
    Lim, Kyung Taek
    Hwang, Jisung
    Cho, Gyuseong
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1063
  • [34] Investigation of water transport around the root for a plant using X-ray imaging technique
    Jung, Sung Yong
    Lee, Sang Joon
    Park, Hanwook
    MEASUREMENT, 2020, 151
  • [35] Using X-Ray CT Scanning to Study the Failure Mechanism of Concrete under Static and Dynamic Loadings
    Lei, Guangyu
    Han, Jichang
    Dang, Faning
    ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2018, 2018
  • [36] Manufacture of Bonded Granular Soil Using X-Ray CT Scanning and 3D Printing
    Matsumura, Satoshi
    Kobayashi, Takaaki
    Mizutani, Takaaki
    Bathurst, Richard J.
    GEOTECHNICAL TESTING JOURNAL, 2017, 40 (06): : 1000 - 1010
  • [37] Unmasking pipefish otolith using synchrotron-based scanning X-ray fluorescence
    Vincent Haÿ
    Sophie Berland
    Kadda Medjoubi
    Andrea Somogyi
    Marion I. Mennesson
    Philippe Keith
    Clara Lord
    Scientific Reports, 13
  • [38] Unmasking pipefish otolith using synchrotron-based scanning X-ray fluorescence
    Hay, Vincent
    Berland, Sophie
    Medjoubi, Kadda
    Somogyi, Andrea
    Mennesson, Marion I.
    Keith, Philippe
    Lord, Clara
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [39] Mesoscopic Study on Frozen State of Graded Crushed Stone Based on X-Ray CT Scanning Technology
    Cui Y.
    Cui, Yinghui (714715617@qq.com), 2018, Chinese Academy of Railway Sciences (39): : 15 - 21
  • [40] Adaptive CT scanning - mesh based optimisation methods for industrial X-ray computed tomography applications
    Hofmann, J
    Flisch, A
    Obrist, A
    NDT & E INTERNATIONAL, 2004, 37 (04) : 271 - 278