Direct and Two-Step Positioning in Visible Light Systems

被引:58
|
作者
Keskin, Musa Furkan [1 ]
Gezici, Sinan [1 ]
Arikan, Orhan [1 ]
机构
[1] Bilkent Univ, Dept Elect & Elect Engn, TR-06800 Ankara, Turkey
关键词
Estimation; Cramer-Rao lower bound; visible light; Lambertian pattern; direct positioning; two-step positioning; DIRECT LOCALIZATION; COMMUNICATION; ACCURACY;
D O I
10.1109/TCOMM.2017.2757936
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Visible light positioning (VLP) systems based on light emitting diodes can facilitate high accuracy localization services for indoor scenarios. In this paper, direct and two-step positioning approaches are investigated for both synchronous and asynchronous VLP systems. First, the Cramer-Rao lower bound (CRLB) and the direct positioning-based maximum likelihood estimator are derived for 3-D localization of a visible light communication receiver in a synchronous scenario by utilizing information from both time delay parameters and channel attenuation factors. Then, a two-step position estimator is designed for synchronous VLP systems by exploiting the asymptotic properties of time-of-arrival and received signal strength estimates. The proposed two-step estimator is shown to be asymptotically optimal, i.e., converges to the direct estimator at high signal-to-noise ratios. In addition, the CRLB and the direct and two-step estimators are obtained for positioning in asynchronous VLP systems. It is proved that the two-step position estimation is optimal in asynchronous VLP systems for practical pulse shapes. Various numerical examples are provided to illustrate the improved performance of the proposed estimators with respect to the current state-of-the-art and to investigate their robustness against model uncertainties in VLP systems.
引用
收藏
页码:239 / 254
页数:16
相关论文
共 50 条
  • [21] Optimal pulse design for visible light positioning systems
    Yazar, Onurcan
    Gezici, Sinan
    SIGNAL PROCESSING, 2022, 191
  • [22] Characterization of two-step direct somatic embryogenesis in carrot
    Takeda, Toshiya
    Mizukami, Miki
    Matsuoka, Hiroshi
    BIOCHEMICAL ENGINEERING JOURNAL, 2008, 38 (02) : 206 - 211
  • [23] Biodegradable nanoparticles for direct or two-step tumor immunotargeting
    Nobs, L
    Buchegger, F
    Gurny, R
    Allémann, E
    BIOCONJUGATE CHEMISTRY, 2006, 17 (01) : 139 - 145
  • [24] A New Two-Step Calibration Method for Structured Light Systems Using Block Gages
    Elmenshawy, Shaza
    Khalil, Abdallah
    Younes, Mohammad A.
    2021 12TH INTERNATIONAL CONFERENCE ON MECHANICAL AND AEROSPACE ENGINEERING (ICMAE), 2021, : 518 - 522
  • [25] Two-Step Wireless Positioning Technique by Exploitation of Extended Reference Nodes
    He, Yu
    Wang, Xianbin
    Hou, Weikun
    2014 IEEE INTERNATIONAL CONFERENCE ON COMMUNICATIONS (ICC), 2014, : 4595 - 4600
  • [26] A WiFi Indoor Positioning Strategy Based on Two-step Fingerprint Matching
    Pei, Yujie
    Wang, Bing
    Zhang, Lan
    2021 PROCEEDINGS OF THE 40TH CHINESE CONTROL CONFERENCE (CCC), 2021, : 5696 - 5701
  • [27] Two-step model of light propagation in biological tissues
    Papaev, A. V.
    Simonenko, G. V.
    Tuchin, V. V.
    JOURNAL OF OPTICAL TECHNOLOGY, 2007, 74 (10) : 675 - 678
  • [28] The two-step
    Loizou, Nicolette
    DANCING TIMES, 2019, 109 (1308): : 64 - 65
  • [29] The Usage of ANN for Regression Analysis in Visible Light Positioning Systems
    Chaudhary, Neha
    Younus, Othman Isam
    Alves, Luis Nero
    Ghassemlooy, Zabih
    Zvanovec, Stanislav
    SENSORS, 2022, 22 (08)
  • [30] Bond strengths of two-step and one-step adhesive systems
    Kelsey, WP
    Triolo, PT
    Blankenau, RJ
    Kelsey, MN
    Hauser, D
    Ortmeier, C
    JOURNAL OF DENTAL RESEARCH, 1996, 75 : 1922 - 1922