Suspended-drop electroporation for high-throughput delivery of biomolecules into cells
被引:30
|
作者:
Guignet, Emmanuel G.
论文数: 0引用数: 0
h-index: 0
机构:
Stanford Univ, Sch Med, Dept Chem & Syst Biol, Bio X Program,Clark Ctr, Stanford, CA 94305 USAStanford Univ, Sch Med, Dept Chem & Syst Biol, Bio X Program,Clark Ctr, Stanford, CA 94305 USA
Guignet, Emmanuel G.
[1
]
Meyer, Tobias
论文数: 0引用数: 0
h-index: 0
机构:
Stanford Univ, Sch Med, Dept Chem & Syst Biol, Bio X Program,Clark Ctr, Stanford, CA 94305 USAStanford Univ, Sch Med, Dept Chem & Syst Biol, Bio X Program,Clark Ctr, Stanford, CA 94305 USA
Meyer, Tobias
[1
]
机构:
[1] Stanford Univ, Sch Med, Dept Chem & Syst Biol, Bio X Program,Clark Ctr, Stanford, CA 94305 USA
We present a high-throughput method that enables efficient delivery of biomolecules into cells. The device consists of an array of 96 suspended electrode pairs, where small sample volumes are top-loaded, electroporated and bottom-ejected into 96-well plates. We demonstrate the use of this suspended-drop electroporation (SDE) device to effectively introduce fluorescent dextran, small interfering RNA (siRNA) or cDNA into primary neurons, differentiated neutrophils and other cell types with conventionally low transfection rates.