Fetal Heart Rate Detection Algorithm from Noninvasive Fetal Electrocardiogram

被引:0
|
作者
Nadila, Hasna [1 ]
Danudirdjo, Donny [1 ]
Zakaria, Hasballah [1 ]
机构
[1] Bandung Inst Technol, Elect & Informat Engn, Bandung, Indonesia
关键词
NIFECG; FHR; TS; SNR; FQRS detection; QRS DETECTION; RATE EXTRACTION; ECG; COMBINATION;
D O I
10.1109/IBITeC53045.2021.9649332
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Noninvasive fetal electrocardiogram (NIFECG) has the potential to measure fetal heart rate (FHR). However, it has low signal-to-noise ratio (SNR) because of many interferences, mainly from the mother's biosignal. The algorithm to measure FHR from NIFECG generally consists of three steps, i.e. preprocessing, FECG extraction, and fetal QRS (FQRS) detection. One of the methods to extract FECG is template subtraction (TS), which does not require many channels. Nevertheless, it cannot significantly enhance the SNR. While for the QRS detection, the Pan-Tompkins algorithm is frequently used but initially designed for the adult ECG. Other than low SNR, NIFECG also faces a problem related to the standard configuration. It is still unknown where the electrodes placement can produce optimal FECG signal quality. Hence, this study aimed to increase FHR accuracy by developing an algorithm based on template subtraction and modified Pan-Tompkins. This study also proposed a channel selection process to eliminate low SNR channels interfering with FHR detection. Another objective was to analyze the electrode placement of NIFECG that has an optimal FECG quality based on its SNR value. The results showed that the proposed algorithm could produce mean absolute error (MAE) of 1.68 ms and mean square error (MSE) of 8.04 bpm2. Increasing the SNR threshold for channel selection could decrease MAE and MSE to 1.00 ms and 1.11 bpm2. Electrodes placement analysis from the Matonia dataset configuration showed that channel three has the highest SNR FECG value (20.18 dB) compared to the other channels.
引用
下载
收藏
页码:71 / 76
页数:6
相关论文
共 50 条
  • [21] Fetal Electrocardiogram Extraction and R-Peak Detection for Fetal Heart Rate Monitoring using Artificial Neural Network and Correlation
    Hasan, M. A.
    Reaz, M. B. I.
    Ibrahimy, M. I.
    2011 INTERNATIONAL JOINT CONFERENCE ON NEURAL NETWORKS (IJCNN), 2011, : 15 - 20
  • [22] Noninvasive fetal electrocardiography for the detection of fetal arrhythmias
    Behar, Joachim A.
    Bonnemains, Laurent
    Shulgin, Vyacheslav
    Oster, Julien
    Ostras, Oleksii
    Lakhno, Igor
    PRENATAL DIAGNOSIS, 2019, 39 (03) : 178 - 187
  • [23] An algorithm for the ambulatory monitoring of fetal heart rate
    Ibrahimy, MI
    Li, MAM
    Zahedi, E
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 3048 - 3051
  • [24] Intrapartum Heart Rate Ambiguity: A Comparison of Cardiotocogram and Abdominal Fetal Electrocardiogram with Maternal Electrocardiogram
    Reinhard, Joscha
    Hayes-Gill, Barrie R.
    Schiermeier, Sven
    Hatzmann, Hendrike
    Heinrich, Tomas M.
    Louwen, Frank
    GYNECOLOGIC AND OBSTETRIC INVESTIGATION, 2013, 75 (02) : 101 - 108
  • [25] NONINVASIVE FETAL ECG MODE FETAL HEART-RATE MONITORING BY ADAPTIVE DIGITAL FILTERING
    FRANK, TH
    BLAUMANIS, OR
    CHEN, SH
    PETRIE, RH
    GIBBS, RK
    WELLS, RL
    JOHNSON, TRB
    JOURNAL OF PERINATAL MEDICINE, 1992, 20 (02) : 93 - 100
  • [26] PhysioNet/CinC Challenge 2013: A Novel Noninvasive Technique to Recognize Fetal QRS Complexes from Noninvasive Fetal Electrocardiogram Signals
    Ghaffari, Ali
    Atyabi, Seyyed Abbas
    Mollakazemi, Mohammad Javad
    Niknazar, Mohammad
    Niknami, Maryam
    Soleimani, Ali
    2013 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), 2013, 40 : 293 - 296
  • [27] 408 Monitoring the Fetal Heart Rate and Fetal Electrocardiogram: Abdominal Recordings are as Good as Direct ECG Measurements
    R Vullings
    C H L Peters
    P Andriessen
    S G Oei
    P F F Wijn
    Pediatric Research, 2005, 58 (2) : 424 - 424
  • [28] A new algorithm for fetal heart rate detection: Fractional order calculus approach
    Tanaskovic, Ilija
    Miljkovic, Nadica
    MEDICAL ENGINEERING & PHYSICS, 2023, 118
  • [29] The influence of betamethasone on fetal heart rate variability, obtained by non-invasive fetal electrocardiogram recordings
    Verdurmen, Kim M. J.
    Warmerdam, Guy J. J.
    Lempersz, Carlijn
    Hulsenboom, Alexandra D. J.
    Renckens, Joris
    Dieleman, Jeanne P.
    Vullings, Rik
    van Laar, Judith O. E. H.
    Oei, S. Guid
    EARLY HUMAN DEVELOPMENT, 2018, 119 : 8 - 14
  • [30] Improved auto-correlation algorithm for Doppler fetal heart rate detection
    School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, China
    Hsi An Chiao Tung Ta Hsueh, 2007, 4 (407-411):