Rapid detection of Salmonella in food and feed by coupling loop-mediated isothermal amplification with bioluminescent assay in real-time

被引:47
|
作者
Yang, Qianru [1 ,2 ]
Domesle, Kelly J. [1 ]
Wang, Fei [1 ,3 ]
Ge, Beilei [1 ]
机构
[1] US FDA, Ctr Vet Med, Res Off, Div Anim & Food Microbiol, Laurel, MD 20708 USA
[2] Louisiana State Univ, Ctr Agr, Dept Food Sci, Baton Rouge, LA 70803 USA
[3] Univ Maryland, Dept Nutr & Food Sci, College Pk, MD 20742 USA
来源
BMC MICROBIOLOGY | 2016年 / 16卷
关键词
LAMP; BART; Salmonella; Food; Feed; Detection; POLYMERASE-CHAIN-REACTION; IN-GROUND BEEF; FOODBORNE SALMONELLA; PCR; LAMP; SEROVARS; CONTAMINATION; PREVALENCE; MONOAZIDE; PRODUCE;
D O I
10.1186/s12866-016-0730-7
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Background: Salmonella is among the most significant pathogens causing food and feed safety concerns. This study examined the rapid detection of Salmonella in various types of food and feed samples by coupling loop-mediated isothermal amplification (LAMP) with a novel reporter, bioluminescent assay in real-time (BART). Performance of the LAMP-BART assay was compared to a conventional LAMP and the commercially available 3M Molecular Detection Assay (MDA) Salmonella. Results: The LAMP-BART assay was 100 % specific among 178 strains (151 Salmonella and 27 non-Salmonella) tested. The detection limits were 36 cells per reaction in pure culture and 10(4) to 10(6) CFU per 25 g in spiked food and feed samples without enrichment, which were comparable to those of the conventional LAMP and 3M MDA Salmonella but 5-10 min faster. Ground turkey showed a strong inhibition on 3M MDA Salmonella, requiring at least 10(8) CFU per 25 g for detection. The correlation between Salmonella cell numbers and LAMP-BART signals was high (R-2 = 0.941-0.962), suggesting good quantification capability. After 24 h enrichment, all three assays accurately detected 1 to 3 CFU per 25 g of Salmonella among five types of food (cantaloupe, ground beef, ground turkey, shell eggs, and tomato) and three types of feed (cattle feed, chicken feed, and dry dog food) examined. However, 10(1) CFU per 25 g was required for cattle feed when tested by 3M MDA Salmonella. Conclusions: The Salmonella LAMP-BART assay was rapid, specific, sensitive, quantitative, and robust. Upon further validation, it may become a valuable tool for routine screening of Salmonella in various types of food and feed samples.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Rapid detection of food-borne Listeria monocytogenes by real-time quantitative loop-mediated isothermal amplification
    Xiaoxiao Shan
    Yaoqi Zhang
    Zhigang Zhang
    Miaorui Chen
    Yongyu Su
    Yingna Yuan
    M. Jahangir Alam
    He Yan
    Lei Shi
    Food Science and Biotechnology, 2012, 21 : 101 - 106
  • [32] Rapid Detection of Food-borne Listeria monocytogenes by Real-time Quantitative Loop-mediated Isothermal Amplification
    Shan, Xiaoxiao
    Zhang, Yaoqi
    Zhang, Zhigang
    Chen, Miaorui
    Su, Yongyu
    Yuan, Yingna
    Alam, M. Jahangir
    Yan, He
    Shi, Lei
    FOOD SCIENCE AND BIOTECHNOLOGY, 2012, 21 (01) : 101 - 106
  • [33] The Rapid Detection of Salmonella from Food Samples By Loop-Mediated Isothermal Amplification (LAMP)
    Ueda, Shigeko
    Kuwabara, Yoshihiro
    BIOCONTROL SCIENCE, 2009, 14 (02) : 73 - 76
  • [34] Real-time loop-mediated isothermal amplification (real-time LAMP) assay for rapid diagnosis of amoebic liver abscess
    Khunger, Sandhya
    Mewara, Abhishek
    Kaur, Upninder
    Duseja, Ajay
    Ray, Pallab
    Kalra, Naveen
    Sharma, Navneet
    Sehgal, Rakesh
    TROPICAL MEDICINE & INTERNATIONAL HEALTH, 2024, 29 (02) : 104 - 112
  • [35] Development of a real-time loop-mediated isothermal amplification assay for detection of porcine circovirus 3
    Wang, Huanan
    Liu, Xiangnan
    Zeng, Fanwen
    Zhang, Tongyuan
    Lian, Yuexiao
    Wu, Miaoli
    Xiao, Li
    Zhu, Yujun
    Zhang, Yu
    Chen, Meili
    Huang, Ren
    Luo, Manlin
    Cong, Feng
    Guo, Pengju
    BMC VETERINARY RESEARCH, 2019, 15 (01)
  • [36] Development of a real-time loop-mediated isothermal amplification assay for detection of porcine circovirus 3
    Huanan Wang
    Xiangnan Liu
    Fanwen Zeng
    Tongyuan Zhang
    Yuexiao Lian
    Miaoli Wu
    Li Xiao
    Yujun Zhu
    Yu Zhang
    Meili Chen
    Ren Huang
    Manlin Luo
    Feng Cong
    Pengju Guo
    BMC Veterinary Research, 15
  • [37] Evaluation of the real-time fluorescence loop-mediated isothermal amplification assay for the detection of Ureaplasma urealyticum
    Shen, Jie-Ni
    Ye, Jing-Yi
    Lao, Meng-Xiao
    Wang, Chu-Qiao
    Wu, Dong-Hong
    Chen, Xiao-Ying
    Lin, Li-Hong
    Geng, Wen-Yan
    Guo, Xu-Guang
    AMB EXPRESS, 2022, 12 (01)
  • [38] Evaluation of the real-time fluorescence loop-mediated isothermal amplification assay for the detection of Streptococcus agalactiae
    Guo, Xu-Guang
    Zhuang, Ya-Ru
    Wen, Jin-Zhou
    Xie, Tian-Ao
    Liu, Ye-Ling
    Zhu, Guo-Dong
    Xia, Yong
    BIOSCIENCE REPORTS, 2019, 39
  • [39] Evaluation of the real-time fluorescence loop-mediated isothermal amplification assay for the detection of Ureaplasma urealyticum
    Jie-Ni Shen
    Jing-Yi Ye
    Meng-Xiao Lao
    Chu-Qiao Wang
    Dong-Hong Wu
    Xiao-Ying Chen
    Li-Hong Lin
    Wen-Yan Geng
    Xu-Guang Guo
    AMB Express, 12
  • [40] Propidium monoazide real-time loop-mediated isothermal amplification for specific visualization of viable Salmonella in food
    Fang, J.
    Wu, Y.
    Qu, D.
    Ma, B.
    Yu, X.
    Zhang, M.
    Han, J.
    LETTERS IN APPLIED MICROBIOLOGY, 2018, 67 (01) : 79 - 88