Direct Measurement of Tibial Cortical Bone Surface Area

被引:1
|
作者
Cattrysse, E. [1 ]
Scafoglieri, A.
Louis, O. [2 ]
De Mey, J. [2 ]
Clarys, J. P.
机构
[1] Vrije Univ Brussel, Fac Med & Pharm, Fac Phys Educ & Physiotherapy, Dept Expt Anat, Brussels, Belgium
[2] Univ Hosp Brussels, Dept Med Imaging, Brussels, Belgium
关键词
tibia; cortical bone; surface area; in vitro; direct estimation; repeatability; BILATERAL ASYMMETRY; MINERAL DENSITY; THICKNESS; RADIUS; ROBUSTICITY; MORPHOMETRY; INVOLUTION; STRENGTH; HUMERUS; SIZE;
D O I
10.1002/ca.20994
中图分类号
R602 [外科病理学、解剖学]; R32 [人体形态学];
学科分类号
100101 ;
摘要
Cortical bone surface area estimation is generally performed by analysis of medical images but its accuracy has not yet been verified by direct bone measurements. This study was performed to evaluate the reproducibility of direct ex vivo estimations of cross sectional tibial cortical bone surface area. Ten tibiae were evaluated by two observers using direct 3D-digitization at 38 and 66% of total tibial length using a 'critical' and a 'general' criterion for differentiation between cortical and cancellous bone. The results of the analysis using the more severe 'critical' differentiation criterion yielded high intra and interobserver agreement. Mean intraobserver reliability was demonstrated by R = 0.98 (Spearman rank correlation between 0.98 and 0.97; P < 0.01) and inter observer reliability by R = 0.91 (Spearman rank correlation between 0.95 and 0.88; P < 0.01). When using strict criteria to differentiate between cortical and cancellous bone, intra and interobserver reliability of the presented method of direct cortical bone surface area estimation is very high. The results indicate that cross-sectional cortical bone surface estimation by direct 3D-digitization can serve as a gold standard for validation of other estimations methods. Clin. Anat. 23: 720-725, 2010. (C) 2010 Wiley-Liss, Inc.
引用
收藏
页码:720 / 725
页数:6
相关论文
共 50 条
  • [21] Anisotropic properties of human tibial cortical bone as measured by nanoindentation
    Fan, Z
    Swadener, JG
    Rho, JY
    Roy, ME
    Pharr, GM
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2002, 20 (04) : 806 - 810
  • [22] Development of Cortical Bone Geometry in the Human Femoral and Tibial Diaphysis
    Gosman, James H.
    Hubbell, Zachariah R.
    Shaw, Colin N.
    Ryan, Timothy M.
    ANATOMICAL RECORD-ADVANCES IN INTEGRATIVE ANATOMY AND EVOLUTIONARY BIOLOGY, 2013, 296 (05): : 774 - 787
  • [23] Anisotropy of Young's modulus of human tibial cortical bone
    B. K. Hoffmeister
    S. R. Smith
    S. M. Handley
    J. Y. Rho
    Medical and Biological Engineering and Computing, 2000, 38 : 333 - 338
  • [24] Visualization and measurement of the cortical surface
    Wandell, BA
    Chial, S
    Backus, BT
    JOURNAL OF COGNITIVE NEUROSCIENCE, 2000, 12 (05) : 739 - 752
  • [25] Elasticity and viscoelasticity of human tibial cortical bone measured by nanoindentation
    Silva, LDS
    Ebacher, V
    Liu, DM
    McKay, H
    Oxland, TR
    Wang, RZ
    Structure and Mechanical Behavior of Biological Materials, 2005, 874 : 91 - 96
  • [26] Tibial cortical bone graft and pre-implant surgery
    Salsedo, I.
    REVUE DE STOMATOLOGIE ET DE CHIRURGIE MAXILLO-FACIALE, 2009, 110 (02): : 94 - 97
  • [27] Total body bone mineral content and tibial cortical bone measures in preschool children
    Specker, BL
    Johannsen, N
    Binkley, T
    Finn, K
    JOURNAL OF BONE AND MINERAL RESEARCH, 2001, 16 (12) : 2298 - 2305
  • [28] Surface kinetics analysis by direct area measurement: Laser assisted dehydration of α-FeOOH
    Sendova, Mariana
    AIP ADVANCES, 2019, 9 (07)
  • [29] HUMAN SURFACE AREA - COMPARISON OF DU BOIS FORMULA WITH DIRECT PHOTOMETRIC MEASUREMENT
    MITCHELL, D
    STRYDOM, NB
    VANGRAAN, CH
    VANDERWA.WH
    PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1971, 325 (02): : 188 - &
  • [30] Cortical Area vs Bone Area: Assessing Intracortical and Endosteal Bone Loss With Age
    Dominguez, Victoria M.
    Agnew, Amanda M.
    AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 2017, 162 : 163 - 164