A new cone-beam CT repositioning technique through deformable registration

被引:0
|
作者
Li, T [1 ]
Yang, Y [1 ]
Schreibmann, E [1 ]
Xing, L [1 ]
机构
[1] Stanford Univ, Sch Med, Stanford, CA 94305 USA
关键词
D O I
10.1118/1.1998652
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop a novel technique to fully utilize the 3D anatomic information provided by cone‐beam CT (CBCT) on‐board imager for automated patient repositioning and quantitatively evaluate its performance by comparing with the existing CBCT‐guided positioning techniques. Method and Materials: A pelvis phantom consisting of bladder, prostate, rectum, and bony structures, was constructed and scanned using a GE Discovery‐ST CT for treatment planning. After applying a deformation, it was scanned again with both Varian Trilogy on‐board CBCT and the regular GE CT. The internal movement of the prostate was studied by using a BSpline deformable model. With the deformable registration, the displacement of each point in the prostate‐target was obtained, and the repositioning parameters were subsequently calculated by minimizing the least‐square distance of all the target points between the two setups. The method was compared with the currently used positioning methods including bony anatomy alignment and minimizing CT‐number difference (MCD) via rigid transformation. Results: Both the proposed and the MCD method showed differences from bony anatomy alignment, reflecting the fact of independent internal organ motion. Discrepancy between the proposed and the MCD method was also observed: 12mm in x‐, 9mm in y‐, and 5mm in z‐axis, respectively. The proposed method presented a better overall accuracy for the target localization as judged by the least‐square distance. When regular CT was used instead of CBCT for positioning, consistent result was obtained by the proposed method, while the MCD method generated different positioning parameters. Conclusion: With the proposed CBCT‐guided repositioning technique, the uncertainty of soft‐tissue target localization could be greatly reduced, ensuring conformal dose distribution to be precisely delivered as planned. This also allows implementation of conformal radiotherapy with smaller margins than currently applied, leading to less complications and improved outcome of the treatment. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2160 / 2160
页数:1
相关论文
共 50 条
  • [21] Deformable Registration of the Inflated and Deflated Lung for Cone-Beam CT-Guided Thoracic Surgery
    Uneri, Ali
    Nithiananthan, Sajendra
    Schafer, Sebastian
    Otake, Yoshito
    Stayman, J. Webster
    Kleinszig, Gerhard
    Sussman, Marc S.
    Taylor, Russell H.
    Prince, Jerry L.
    Siewerdsen, Jeffrey H.
    MEDICAL IMAGING 2012: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2012, 8316
  • [22] Deformable image registration in cone-beam CT images for image-guided adaptive radiotherapy
    Zhang, L.
    Dong, L.
    Zhu, X.
    Garden, A.
    Ahamad, A.
    Ang, K.
    Mohan, R.
    MEDICAL PHYSICS, 2006, 33 (06) : 1995 - 1995
  • [23] Deformable Registration for Intra-Operative Cone-Beam CT Guidance of Head and Neck Surgery
    Nithiananthan, Sajendra
    Brock, Kristy K.
    Irish, Jonathan C.
    Siewerdsen, Jeffrey H.
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 3634 - +
  • [24] Deformable image registration for contour propagation from CT to cone-beam CT scans in radiotherapy of prostate cancer
    Thor, Maria
    Petersen, Jorgen B. B.
    Bentzen, Lise
    Hoyer, Morten
    Muren, Ludvig Paul
    ACTA ONCOLOGICA, 2011, 50 (06) : 918 - 925
  • [25] Evaluation of Deformable Image Registration-Based Contour Propagation From Planning CT to Cone-Beam CT
    Woerner, Andrew J.
    Choi, Mehee
    Harkenrider, Matthew M.
    Roeske, John C.
    Surucu, Murat
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2017, 16 (06) : 801 - 810
  • [26] Incorporating the synthetic CT image for improving the performance of deformable image registration between planning CT and cone-beam CT
    Li, Na
    Zhou, Xuanru
    Chen, Shupeng
    Dai, Jingjing
    Wang, Tangsheng
    Zhang, Chulong
    He, Wenfeng
    Xie, Yaoqin
    Liang, Xiaokun
    FRONTIERS IN ONCOLOGY, 2023, 13
  • [27] Deformable registration of lateral cephalogram and cone-beam computed tomography image
    Zhang, Yungeng
    Qin, Haifang
    Li, Peixin
    Pei, Yuru
    Guo, Yuke
    Xu, Tianmin
    Zha, Hongbin
    MEDICAL PHYSICS, 2021, 48 (11) : 6901 - 6915
  • [28] Assessing the impact of choosing different deformable registration algorithms on cone-beam CT enhancement by histogram matching
    Kidar, Halima Saadia
    Azizi, Hacene
    RADIATION ONCOLOGY, 2018, 13
  • [29] 4D Cone-beam CT Deformable Registration using Unsupervised Spatial Transformation Network
    Wang, Tonghe
    Lei, Yang
    Tian, Zhen
    Giles, Matt
    Bradley, Jeffrey D.
    Curran, Walter J.
    Liu, Tian
    Yang, Xiaofeng
    MEDICAL IMAGING 2021: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2021, 11600
  • [30] Assessing the impact of choosing different deformable registration algorithms on cone-beam CT enhancement by histogram matching
    Halima Saadia Kidar
    Hacene Azizi
    Radiation Oncology, 13