Ion excitation in a linear quadrupole ion trap with an added octopole field

被引:48
|
作者
Michaud, AL [1 ]
Frank, AJ [1 ]
Ding, C [1 ]
Zhao, XZ [1 ]
Douglas, DJ [1 ]
机构
[1] Univ British Columbia, Dept Chem, Vancouver, BC V6T 1Z1, Canada
关键词
D O I
10.1016/j.jasms.2005.02.006
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Modeling of ion motion and experimental investigations of ion excitation in a linear quadrupole trap with a 4 % added octopole field are described. The results are compared with those obtained with a conventional round rod set. Motion in the effective potential of the rod set can explain many of the observed phenomena. The frequencies of ion oscillation in the x and y directions shift with amplitude in opposite directions as the amplitudes of oscillation increase. Excitation profiles for ion fragmentation become asymmetric and in some cases show bistable behavior where the amplitude of oscillation suddenly jumps between high and low values with very small changes in excitation frequency. Experiments show these effects. Ions are injected into a linear trap, stored, isolated, excited for MS/MS, and then mass analyzed in a time-of-flight mass analyzer. Frequency shifts between the x and y motions are observed, and in some cases asymmetric excitation profiles and bistable behavior are observed. Higher MS/MS efficiencies are expected when an octopole field is added. MS/MS efficiencies ((2) collision gas) have been measured for a conventional quadrupole rod set and a linear ion trap with a 4 % added octopole field. Efficiencies are chemical compound dependent, but when an octopole field is added, efficiencies can be substantially higher than with a conventional rod set, particularly at pressures of 1.4 X 10(-4) torr or less. (c) 2005 American Society for Mass Spectrometry.
引用
收藏
页码:835 / 849
页数:15
相关论文
共 50 条
  • [41] Resonance excitation in a quadrupole ion trap: Modification of competing dissociative channel yields
    Liere, P
    March, RE
    Blasco, T
    Tabet, JC
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1996, 153 (2-3): : 101 - 117
  • [42] Development and application of digital control technology of resonant excitation for quadrupole ion trap
    Jiang You
    Fang Xiang
    Rang Yu
    Tian Di
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2008, 36 (05) : 715 - 718
  • [43] Resonant excitation in a low-pressure linear ion trap
    Collings, B.A. (bruce.collings@sciex.com), 1600, Elsevier Inc. (14):
  • [44] Optimum Radius Size between Cylindrical Ion Trap and Quadrupole Ion Trap
    Chaharborj, Sarkhosh Seddighi
    Kiai, Seyyed Mahmod Sadat
    Arifin, Norihan Md
    Gheisari, Yousof
    MASS SPECTROMETRY LETTERS, 2015, 6 (03) : 59 - 64
  • [45] The effect of ion trap temperature on the dissociation of peptide ions in a quadrupole ion trap
    Jue, April L.
    Racine, Alawee H.
    Glish, Gary L.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2011, 301 (1-3) : 74 - 83
  • [46] RESONANCE EXCITATION OF IONS STORED IN A QUADRUPOLE ION TRAP .3. INTRODUCTION TO THE FIELD INTERPOLATION SIMULATION METHOD
    MARCH, RE
    LONDRY, FA
    ALFRED, RL
    TODD, JFJ
    PENMAN, AD
    VEDEL, F
    VEDEL, M
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1991, 110 (03): : 159 - 178
  • [47] Designing of a Quadrupole Paul Ion Trap
    Abouzar Kiyani
    M. Abdollahzadeh
    S. M. Sadat Kiai
    A. R. Zirak
    Journal of Fusion Energy, 2011, 30 : 291 - 293
  • [48] Quadrupole ion trap mass spectrometry
    Schwartz, JC
    Jardine, I
    HIGH RESOLUTION SEPARATION AND ANALYSIS OF BIOLOGICAL MACROMOLECULES, PT A, 1996, 270 : 552 - 586
  • [49] Improving IRMPD in a Quadrupole Ion Trap
    Newsome, G. Asher
    Glish, Gary L.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2009, 20 (06) : 1127 - 1131
  • [50] Designing of a Quadrupole Paul Ion Trap
    Kiyani, Abouzar
    Abdollahzadeh, M.
    Kiai, S. M. Sadat
    Zirak, A. R.
    JOURNAL OF FUSION ENERGY, 2011, 30 (04) : 291 - 293