Magnetic losses in Bi2223 high temperature superconductors measured by AC and DC magnetization method

被引:3
|
作者
Hu, L
Zhang, PX
Teng, XK
Wang, JR
Li, CS
Feng, Y
Zhou, L
Ding, SY
Qiu, L
Leng, X
机构
[1] NW Inst Nonferrous Met Res, Superconduct Mat Res Ctr, Xian 710016, Shaanxi, Peoples R China
[2] Nanjing Univ, Dept Phys, Nanjing 210093, Peoples R China
关键词
AC losses; susceptibility; Bi2223;
D O I
10.1016/S0921-4534(03)01117-1
中图分类号
O59 [应用物理学];
学科分类号
摘要
The properties of Bi2223 high temperature superconductor (HTS) tapes are improved in long length and high current-carrying capacity for its applications. But AC loss is still very high, which increases its economic feasibility in power engineering applications. Extensive investigations have shown that the mechanism of generation of AC loss in FITS is different from that in LTS because of its unique characteristics. In this study, AC losses in Bi2223 (HTS) tapes were measured by vibrating sample magnetometer at 77 K and AC susceptibility meter. The effects of different factors, such as, frequency and amplitude of AC applied magnetic field and/or amplitude of DC applied magnetic field, were investigated on the AC susceptibility in Bi2223 HTS tapes. Instead of Bean critical state model, flux dynamics were investigated to describe the experimental results. (C) 2003 Elsevier B.V. All rights reserved.
引用
下载
收藏
页码:1102 / 1106
页数:5
相关论文
共 50 条
  • [21] Angular dependence of ac losses at power frequencies for a stack of Bi2223/Ag tapes
    Chiba, T
    Li, Q
    Ashworth, SP
    Suenaga, M
    Haldar, P
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1999, 9 (02) : 2143 - 2146
  • [22] Understanding of AC transport losses for Ag-sheathed Bi2223 multifilamentary tapes
    Inada, R
    Fukunaga, T
    Oota, A
    ADVANCES IN SUPERCONDUCTIVITY XII, 2000, : 748 - 750
  • [23] AC transport losses of Ag-sheathed Bi2223 multifilamentary twisted tapes
    Fukunaga, T
    Itou, T
    Oota, A
    Maeda, J
    Hiraoka, M
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1997, 7 (02) : 1666 - 1669
  • [24] AC loss in HTS Bi2223 tapes at 4.2K under DC applied magnetic field
    Hu, LF
    Sulpice, A
    Mossang, E
    Li, CS
    Ping, J
    Wu, YF
    Yong, F
    Zhang, PX
    Lian, Z
    RARE METAL MATERIALS AND ENGINEERING, 2003, 32 (09) : 769 - 772
  • [25] Development of GM cryocooler - Cooled Bi2223 high temperature superconducting magnetic separator
    Wang, Qiuliang
    Dai, Yingming
    Hu, Xinning
    Song, Shouseng
    Lei, Yuanzhong
    He, Chuan
    Yan, Luguang
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2007, 17 (02) : 2185 - 2188
  • [26] Fabrication and characterization of Bi2223/Ag tapes with interfilamentary oxide barriers for reducing AC losses
    Inada, R.
    Fukumoto, Y.
    Mitsuno, Y.
    Yasunami, T.
    Nakamura, Y.
    Oota, A.
    Li, C. S.
    Zhang, P. X.
    8TH EUROPEAN CONFERENCE ON APPLIED SUPERCONDUCTIVITY (EUCAS'07), 2008, 97
  • [27] AC loss characteristics of Bi2223 twisted multifilamentary tape in AC longitudinal magnetic field
    Yoshida, T
    Fukui, S
    Yamaguchi, M
    Sato, T
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2003, 13 (02) : 2372 - 2375
  • [28] Pinning in a porous high-temperature superconductor Bi2223
    K. Yu. Terent’ev
    D. M. Gokhfel’d
    S. I. Popkov
    K. A. Shaikhutdinov
    M. I. Petrov
    Physics of the Solid State, 2011, 53 : 2409 - 2414
  • [29] AC losses of a multi-layer conductor using Bi2223 tapes with twisted filaments
    Mukoyama, S
    Tsubouchi, H
    Miyoshi, K
    Yoshida, T
    Mimura, M
    Uno, N
    Honjo, S
    Mimura, T
    Iwata, Y
    Takahashi, Y
    ADVANCES IN SUPERCONDUCTIVITY XII, 2000, : 754 - 756
  • [30] AC magnetic losses in multifilamentary Ag/Bi-2223 tape carrying dc transport current
    Ciszek, M
    Glowacki, BA
    Ashworth, SP
    Chesneau, E
    Campbell, AM
    Evetts, JE
    APPLIED SUPERCONDUCTIVITY 1997, VOLS 1 AND 2: VOL 1: SMALL SCALE AND ELECTRONIC APPLICATIONS; VOL 2: LARGE SCALE AND POWER APPLICATIONS, 1997, (158): : 1425 - 1428