Scatter Factors Comparison of 6MV FFF and Energy Matched 6MV EqFFF

被引:0
|
作者
Sigamani, Ashokkumar [1 ]
Nambiraji, Arunai [1 ]
Sinha, S. N. [2 ]
Yadav, Girigesh [3 ]
Rajesh, T. [4 ]
Raman, Kothanda [3 ]
Kaviarasu, K. [5 ]
Narayanan, S. [6 ]
Meerza, Kazem [6 ]
机构
[1] Vellore Inst Technol, Vellore, Tamil Nadu, India
[2] Nayati Healathcare & Res Pvt Ltd, Mathura, Uttar Pradesh, India
[3] Rajiv Gandhi Canc Inst & Res Ctr, Gurgaon, Haryana, India
[4] Medanta Medicity, Gurgaon, Haryana, India
[5] Krishna Inst Med Sci, Hydrabad, Andrapradesh, India
[6] Kuwait Canc Control Ctr, Kuwait, Kuwait
关键词
D O I
10.1118/1.4925050
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
引用
收藏
页码:3494 / 3495
页数:2
相关论文
共 50 条
  • [1] Scatter Factors Comparison of 6MV Flattened and 7MV Unflattened Beams
    Ashokkumar, S.
    Sinha, S. N.
    Yadav, Girigesh
    Raman, Kothanda
    Thiyagarajan, Rajesh
    Nambiraj, N. Arunai
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3737 - 3737
  • [2] Surface Dose and Build-Up Dose Comparison of 6MV and 10MV Flattened with 6MV FFF and 10MV FFF Photon Beams with Different Detectors
    Nambiraj, Arunai
    Sigamani, Ashokkumar
    Kaviarasu, K.
    Rajesh, T.
    Karthikeyan, S.
    Subramanian, Narayanan
    Meerza, Kazem
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3502 - 3502
  • [3] COMPARISON OF A MONTE CARLO 6MV LINAC MODEL WITH MEASURED 6MV BEAMS FOR PERIPHERAL DOSIMETRY
    Joosten, A.
    Levi, F.
    Baechier, S.
    Mirimanoff, R. O.
    Bochud, F.
    Moeckli, R.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S483 - S483
  • [4] Polarity and ion recombination corrections for SemiFlex 3D 31021 IC in 6MV and 6MV FFF photon beams
    Castellet Garcia, M. C.
    Monasor Denia, P.
    Manjon Garcia, C.
    Lopez Tarjuelo, J.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S921 - S921
  • [5] Treatment planning for a 6MV FFF Halcyon linac as a replacement for a 10MV-capable Clinac
    Withers, D.
    Kidane, G.
    Farmakidis, D.
    Crees, L.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S1073 - S1073
  • [6] Performance of 2.5MV Portal Imaging in Comparison with KV X-Ray and 6MV and Flattening-Filter-Free 6MV Portal Imaging
    Duan, J.
    Yang, Y.
    Faught, A.
    Subashi, E.
    Wu, Q.
    Yin, F.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3411 - 3411
  • [7] A Comparison of a 2.5MV Imaging Beam to KV and 6MV Imaging Beams
    Nitsch, P.
    Robertson, D.
    Balter, P.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3266 - 3266
  • [8] Properties of IBA Razor Nano Chamber in small-field radiation therapy using 6MV FF, 6 MV FFF, and 10 MV FFF photon beams
    Partanen, Mari
    Niemela, Jarkko
    Ojala, Jarkko
    Keyrilainen, Jani
    Kapanen, Mika
    [J]. ACTA ONCOLOGICA, 2021, 60 (11) : 1419 - 1424
  • [9] Comparison of Head Scatter Factor for 6MV and 10MV flattened (FB) and Unflattened (FFF) Photon Beam using indigenously Designed Columnar Mini Phantom
    Ashokkumar, Sigamani
    Raj, Arunai Nambi N.
    Sinha, Sujit Nath
    Yadav, Girigesh
    Thiyagarajan, Rajesh
    Raman, Kothanda
    Mishra, Manindra Bhushan
    [J]. JOURNAL OF MEDICAL PHYSICS, 2014, 39 (03) : 184 - 191
  • [10] Dosimetric and geometric verification of elements multimetastases v.2.0, for 6MV and 6FFF
    Arrizabalaga, Sara Alonso
    Alonso, S.
    Lomax, N.
    Rogers, S.
    Schurkens, J.
    Beltz, M.
    Lutters, G.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2019, 195 (12) : 1124 - 1124