The Angio-Seal Evolution Registry: Outcomes of a Novel Automated Angio-Seal Vascular Closure Device

被引:0
|
作者
Applegate, Robert J. [1 ]
Turi, Zoltan [2 ]
Sachdev, Naveen [3 ]
Ahmed, Abdel [7 ]
Szyniszewski, Arthur
Foster, Malcolm [4 ]
Pratsos, Antonis [4 ]
Shapiro, Timothy [5 ]
Yakubov, Steven [6 ]
Shavelle, David
机构
[1] Wake Forest Univ, Sch Med, Cardiol Sect, Winston Salem, NC 27157 USA
[2] Cooper Univ Hosp, Camden, NJ USA
[3] Prov St Vincent Med Ctr, Prov Heart & Vasc Inst, Portland, OR USA
[4] Baptist Hosp W, Knoxville, TN USA
[5] Lankenau Hosp, Wynnewood, PA USA
[6] Ohio Hlth Res & Innovat Inst, Columbus, OH USA
[7] ALTRU Hlth Syst, Grand Forks, ND USA
来源
JOURNAL OF INVASIVE CARDIOLOGY | 2010年 / 22卷 / 09期
关键词
vascular complications; propensity analysis; cardiac catheterization; percutaneous coronary intervention; PERCUTANEOUS CORONARY INTERVENTION; DIAGNOSTIC CARDIAC-CATHETERIZATION; ACCESS SITE; RANDOMIZED-TRIALS; FEMORAL ACCESS; COMPLICATIONS; METAANALYSIS; IMPACT; PREDICTORS; INHIBITORS;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives The objective of the study was to assess the efficacy and safety of a novel vascular closure device, the Angio-Seal Evolution (EVCD) in patients undergoing routine cardiac catheterization (CATH) and intervention (PCI) via a retrograde femoral artery access Background Successful use of current-generation vascular closure devices is highly dependent on operator methodology To reduce dependence on operator technique the EVCD was modified to automate the closure process, specifically the compaction of the extravascular collagen sponge that creates a sandwich under pressure against the intra-arterial anchor Methods This was a prospective ten-site registry including 1,004 patients undergoing 1,010 procedures with in-laboratory closure using the EVCD after CATH and PCI The primary outcome measure was the rate of major vascular complications and secondary outcomes were deployment saccess time to hemostasis and in-hospital rates of minor vascular complications through 30 days Clinical trial identifier NCT 00817349 Results There were 575 CATH (56 9%) and 435 PCI (43 1%) closures Overall deployment success was 99 7% 99 8% for CATH and 99 5% for PCI Major vascular complications occurred in 0 4% including 0 2% in CATH and 0 7% in PCI Minor vascular complications occurred in 2 4%, with 0 5% for CATH and 4 9% for PCI Conclusions Automation of the anchor-collagen closure of femoral artery access sites with the Angio-Seal ECVD resulted in excellent efficacy and safety after routine cardiac catheterization and intervention
引用
收藏
页码:420 / 426
页数:7
相关论文
共 50 条
  • [31] Device reliability and safety using the angio-seal STS vascular closure device in interventional patients.
    Yakubov, SJ
    Kahn, JK
    Bergman, GW
    Mewissen, MW
    AMERICAN JOURNAL OF CARDIOLOGY, 2001, 88 (5A): : 32G - 32G
  • [32] Off-licence use of the Angio-Seal™ arterial puncture closure device
    Bown, MJ
    Blanshard, KS
    Cutress, ML
    Sayers, RD
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2002, 24 (04) : 372 - 373
  • [33] Safety and Efficacy of the New Angio-Seal Evolution™ Closure Device: A Single-Center Experience
    Lupi, Alessandro
    Lazzero, Maurizio
    Plebani, Laura
    Sansa, Mara
    Bongo, Angelo S.
    JOURNAL OF INVASIVE CARDIOLOGY, 2011, 23 (04): : 150 - 155
  • [34] Novel Technique to Treat Common Femoral Artery Pseudoaneurysm using Angio-Seal Closure Device
    Robken, Jon
    Shammas, Nicolas W.
    INTERNATIONAL JOURNAL OF ANGIOLOGY, 2016, 25 (04) : 266 - 270
  • [35] An evaluation of immediate sheath removal and use of the Angio-Seal vascular closure device in neuroradiological interventions
    L. Pierot
    D. Herbreteau
    S. Bracard
    J. Berge
    C. Cognard
    Neuroradiology, 2006, 48 : 45 - 49
  • [36] Images of angioscopy and intravascular ultrasound for dislodged Angio-Seal(R) VIP vascular closure device
    Ito, N.
    Hishikari, K.
    Hikita, H.
    Takahashi, A.
    Yonetsu, T.
    Sasano, T.
    CARDIOVASCULAR INTERVENTION AND THERAPEUTICS, 2022, 37 (03) : 585 - 586
  • [37] The 6Fr Angio-seal arterial closure device: Results from a multimember prospective registry
    Kapadia, SR
    Raymond, R
    Knopf, W
    Jenkins, S
    Chapekis, A
    Ansel, G
    Rothbaum, D
    Kussmaul, W
    Teirstein, P
    Reisman, M
    Casale, P
    Oster, L
    Simpfendorfer, C
    AMERICAN JOURNAL OF CARDIOLOGY, 2001, 87 (06): : 789 - +
  • [38] THE ANGIO-SEAL EVOLUTION MULTICENTER REGISTRY: MULTIVARIATE ANALYSIS OF VASCULAR COMPLICATIONS IN HIGH RISK PATIENTS
    Applegate, Robert J.
    Turi, Zoltan
    Sachdev, Naveen
    Ahmed, Abdel
    Szyniszewski, Art
    Foster, Malcolm
    Pratsos, Antonis
    Shapiro, Timothy
    Yakubov, Steven J.
    Shavelle, David M.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [39] The use of the angio-seal haemostatic puncture closure device in high risk patients
    O'Sullivan, GJ
    Buckenham, TM
    Belli, AM
    CLINICAL RADIOLOGY, 1999, 54 (01) : 51 - 55
  • [40] Vascular complications following hemostatic closure with Angio-Seal post abciximab.
    Gardella, JE
    Berrent, G
    Weirzbicki, R
    Steingart, RM
    Marzo, K
    AMERICAN JOURNAL OF CARDIOLOGY, 1998, 82 (7A): : 110S - 111S