To evaluate an interactive computer-aided detection (CAD) system for reading mammograms to improve decision making. A dedicated mammographic workstation has been developed in which readers can probe image locations for the presence of CAD information. If present, CAD findings are displayed with the computed malignancy rating. A reader study was conducted in which four screening radiologists and five non-radiologists participated to study the effect of this system on detection performance. The participants read 120 cases of which 40 cases had a malignant mass that was missed at the original screening. The readers read each mammogram both with and without CAD in separate sessions. Each reader reported localized findings and assigned a malignancy score per finding. Mean sensitivity was computed in an interval of false-positive fractions less than 10%. Mean sensitivity was 25.1% in the sessions without CAD and 34.8% in the CAD-assisted sessions. The increase in detection performance was significant (p = 0.012). Average reading time was 84.7 +/- 61.5 s/case in the unaided sessions and was not significantly higher when interactive CAD was used (85.9 +/- 57.8 s/case). Interactive use of CAD in mammography may be more effective than traditional CAD for improving mass detection without affecting reading time.
引用
收藏
页码:2323 / 2330
页数:8
相关论文
共 50 条
  • [41] Prospective assessment of computer-aided detection in interpretation of screening mammography
    Ko, Justin M.
    Nicholas, Michael J.
    Mendel, Jeffrey B.
    Slanetz, Priscilla J.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 187 (06) : 1483 - 1491
  • [42] Toward Computer-Aided Support for the Detection of Deception
    Judee Burgoon
    Jay Nunamaker
    [J]. Group Decision and Negotiation, 2004, 13 : 1 - 4
  • [43] Introduction: Computer-aided support of the detection of deception
    Burgoon, JK
    Nunamaker, JF
    [J]. GROUP DECISION AND NEGOTIATION, 2004, 13 (02) : 107 - 110
  • [44] Potential contribution of computer-aided detection to the sensitivity of screening mammography
    Burhenne, LJW
    Wood, SA
    D'Orsi, CJ
    Feig, SA
    Kopans, DB
    O'Shaughnessy, KF
    Sickles, EA
    Tabar, L
    Vyborny, CJ
    Castellino, RA
    [J]. RADIOLOGY, 2000, 215 (02) : 554 - 562
  • [45] Improved computer-aided detection (CAD) algorithms for screening mammography
    Castellino, RA
    Roehrig, J
    Zhang, W
    [J]. RADIOLOGY, 2000, 217 : 400 - 400
  • [46] The Preponderance of Evidence Supports Computer-aided Detection for Screening Mammography
    Birdwell, Robyn L.
    [J]. RADIOLOGY, 2009, 253 (01) : 9 - 16
  • [47] Re: Effectiveness of Computer-Aided Detection in Community Mammography Practice
    Nishikawa, Robert M.
    Giger, Maryellen L.
    Jiang, Yulei
    Metz, Charles E.
    [J]. JNCI-JOURNAL OF THE NATIONAL CANCER INSTITUTE, 2012, 104 (01) : 77 - 77
  • [48] Computer-aided detection with screening mammography in a university hospital setting
    Birdwell, RL
    Bandodkar, P
    Ikeda, DM
    [J]. RADIOLOGY, 2005, 236 (02) : 451 - 457
  • [49] Computer-aided detection is an alternative to double-reading mammography
    不详
    [J]. Nature Clinical Practice Oncology, 2009, 6 (2): : 60 - 61
  • [50] Computer-aided diagnosis in screening mammography: Detection of missed cancers
    Nishikawa, RM
    Giger, M
    Schmidt, RA
    Collins, SA
    Doi, K
    [J]. RADIOLOGY, 1998, 209P : 353 - 353