PET and SPECT dual-tracer imaging: Correction of 511keV photon's down-scatter effect on SPECT

被引:3
|
作者
Ma, Tianyu [1 ]
Shao, Yiping [1 ]
Yao, Rutao [1 ]
Manchiraju, Phani [1 ]
机构
[1] SUNY Buffalo, Dept Nucl Med, Buffalo, NY 14214 USA
关键词
D O I
10.1109/NSSMIC.2007.4436861
中图分类号
O59 [应用物理学];
学科分类号
摘要
This work was part of the feasibility study of performing simultaneous PET and SPECT imaging with a microPET scanner. SPECT data were acquired with slit-slat collimation by inserting a slit-slat collimator into microPET's detector ring but were contaminated by 511 keV photons' down-scattered events from PET tracer. In this study, contribution of down-scattered events in Tc-99m energy window (135-145 keV) was characterized through Monte Carlo simulation and measurements. With relative ratio of Tc-99m and F-18 activity being 1:1, ratio of recorded events from Tc-99m and F-18 source was 1:18.31. Nevertheless, simulation results revealed that the majority of down-scattering effects occurred in the detector crystals and thus were less object dependent. We investigated two subtraction-based compensation methods. The first method used an auxiliary energy window (AEW) and the second method employed extra shielding measurement (ESM) to acquire down-scatter- only data. Simulated and experimental studies showed improved image quality after applying the correction methods. With the activity ratio of SPECT tracer to PET tracer being 5:1, good SPECT images were obtained after correction, which were comparable to those from pure SPECT imaging.
引用
收藏
页码:3404 / 3407
页数:4
相关论文
共 50 条
  • [31] Simultaneous F-18 and Se-75 dual-isotope imaging using TOF-PET scanner: Effect of Down-Scatter
    Chiang, C. C.
    Chuang, K. S.
    Lin, H. H.
    Jan, M. L.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S305 - S306
  • [32] Monte Carlo-based scatter correction considering the tailing effect of a CdTe detector for dual-isotope brain SPECT imaging
    Suzuki, Atsuro
    Takeuchi, Wataru
    Ueno, Yuichiro
    Kobashi, Keiji
    Toyonaga, Takuya
    Shiga, Tohru
    Tamaki, Nagara
    [J]. BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2016, 2 (04):
  • [33] Vectorial analysis of dual-tracer PET imaging in Parkinson's disease: a pixel-by-pixel-based approach
    Avendano-Estrada, A.
    Avila-Rodriguez, M.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S300 - S300
  • [34] Combination of dual-phase and dual-tracer SPECT/CT imaging with voxel-based subtraction in the assessment of normocalcemic primary hyperparathyroidism in patients with osteoporosis: a pilot study
    Chroustova, Daniela
    Stepan, Jan
    Trnka, Jiri
    Fialova, Martina
    Kubinyi, Jozef
    [J]. INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2017, 10 (06): : 9518 - 9525
  • [35] Preserved caudate function in young-onset patients with Parkinson's disease: a dual-tracer PET imaging study
    Yang, Yu-jie
    Ge, Jing-jie
    Liu, Feng-tao
    Liu, Zhen-yang
    Zhao, Jue
    Wu, Jian-jun
    Ma, Yilong
    Zuo, Chuan-tao
    Wang, Jian
    [J]. THERAPEUTIC ADVANCES IN NEUROLOGICAL DISORDERS, 2019, 12
  • [36] The impact of probable rapid eye movement sleep behavior disorder on Parkinson's disease: A dual-tracer PET imaging study
    Xu, Qian
    Jiang, Chengfeng
    Ge, Jingjie
    Lu, Jiaying
    Li, Ling
    Yu, Huan
    Wu, Jianjun
    Wang, Jian
    Wu, Ping
    Zuo, Chuantao
    [J]. PARKINSONISM & RELATED DISORDERS, 2022, 95 : 47 - 53
  • [37] The effect of scatter correction and radius of rotation on semiquantitative measurements in SPECT 123I-FP-CIT imaging. A phantom study
    Papanastasiou, Emmanouil
    Katsiva, Christina
    Doumas, Argyrios
    Gerasimou, Georgios
    Siountas, Anastasios
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 69 : 120 - 125
  • [38] Scatter correction based on an artificial neural network for 99mTc and 123I dual-isotope SPECT in myocardial and brain imaging
    Bai, Jingming
    Hashimoto, Jun
    Ogawa, Koichi
    Nakahara, Tadaki
    Suzuki, Takayuki
    Kubo, Atsushi
    [J]. ANNALS OF NUCLEAR MEDICINE, 2007, 21 (01) : 25 - 32
  • [39] Scatter correction based on an artificial neural network for99mTc and123I dual-isotope SPECT in myocardial and brain imaging
    Jingming Bai
    Jun Hashimoto
    Koichi Ogawa
    Tadaki Nakahara
    Takayuki Suzuki
    Atsushi Kubo
    [J]. Annals of Nuclear Medicine, 2007, 21
  • [40] Effect of Sub-energy Windows' Parameters on the Triple Energy Window Scatter Correction Method Accuracy in 99mTc SPECT Imaging
    Saikouk, H.
    El Khayati, N.
    Matrane, A.
    [J]. ATOM INDONESIA, 2022, 48 (01) : 51 - 59