Validation of an automated immunoturbidimetric assay for feline serum amyloid A

被引:10
|
作者
Waugh, Elspeth M. [1 ]
Haining, Hayley [1 ]
Harvie, James [1 ]
Ridyard, Alison E. [2 ]
Eckersall, P. David [3 ]
机构
[1] Univ Glasgow, Sch Vet Med, Vet Diagnost Serv, Glasgow, Lanark, Scotland
[2] Univ Glasgow, Sch Vet Med, Small Anim Clin Serv, Glasgow, Lanark, Scotland
[3] Univ Glasgow, Inst Biodivers Anim Hlth & Comparat Med, Glasgow, Lanark, Scotland
关键词
Serum amyloid A; Assay; Validation; Feline; Inflammation; Acute phase protein; SAA TURBIDIMETRIC IMMUNOASSAY; ACUTE-PHASE PROTEINS; A SAA; CANINE; CATS;
D O I
10.1186/s12917-022-03456-5
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Background Serum Amyloid A (SAA) is a major acute phase protein in cats, increasing rapidly in response to various inflammatory diseases. An automated latex-enhanced immunoturbidimetric assay for human SAA (LZ-SAA, Eiken), previously validated for use in cats, has had further major modification (VET-SAA, Eiken) for specific use in veterinary diagnostic laboratories but has yet to be validated in cats. Results Intra-assay and inter-assay CVs for the VET-SAA assay ranged from 1.88-3.57% and 3.98-6.74%, respectively. Linearity under dilution was acceptable with no prozone effect observed. Limit of detection was 1.65 mg/L and limit of quantification was 6 mg/L. Haemoglobin and triglyceride showed no adverse interference, but bilirubin produced positive bias in samples with low SAA. Comparison with the LZ-SAA assay showed significant correlation with proportional bias increasing as SAA concentration increased, likely related to differing calibration standards. SAA was significantly higher in patients with inflammatory disease compared with non-inflammatory disease, and in patients with moderate to highly elevated alpha 1-AGP compared with patients with normal alpha 1-AGP. Improvement of the assay range may be required to fully evaluate differences between disease groups at low SAA levels. Based on ROC curve analysis, at a cut-off point of 20.1 mg/L the VET-SAA assay discriminated between inflammatory and non-inflammatory disease with sensitivity of 0.93 and specificity of 0.99. Conclusions The automated VET-SAA assay is a robust, precise, and accurate method for measurement of feline SAA which can clearly identify patients with inflammatory disease. It should be a valuable biomarker for use in feline medicine.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] SENSITIVE RAPID DETECTION OF MYOGLOBIN IN SERUM OF PATIENTS WITH MYOPATHY BY IMMUNOTURBIDIMETRIC ASSAY
    LOVECE, S
    KAGEN, LJ
    JOURNAL OF RHEUMATOLOGY, 1993, 20 (08) : 1331 - 1334
  • [42] Measurement of serum amyloid A in the neonatal foal using a latex agglutination immunoturbidimetric assay: determination of the normal range, variation with age and response to disease
    Stoneham, SJ
    Palmer, L
    Cash, R
    Rossdale, PD
    EQUINE VETERINARY JOURNAL, 2001, 33 (06) : 599 - 603
  • [43] Validation of an automated assay for the measurement of cupric reducing antioxidant capacity in serum of dogs
    Peres Rubio, Camila
    Tvarijonaviciute, Asta
    Martinez-Subiela, Silvia
    Hernandez-Ruiz, Josefa
    Joaquin Ceron, Jose
    BMC VETERINARY RESEARCH, 2016, 12
  • [44] DEVELOPMENT AND VALIDATION OF AN AUTOMATED, ENZYME-MEDIATED COLORIMETRIC ASSAY OF SALICYLATE IN SERUM
    MORRIS, HC
    OVERTON, PD
    RAMSAY, JR
    CAMPBELL, RS
    HAMMOND, PM
    ATKINSON, T
    PRICE, CP
    CLINICAL CHEMISTRY, 1990, 36 (01) : 131 - 135
  • [45] Development and validation of an automated assay for anti-drug-antibodies in rat serum
    Terrell, Kristy A.
    Sempowski, Gregory D.
    Macintyre, Andrew N.
    SLAS TECHNOLOGY, 2023, 28 (05): : 361 - 368
  • [46] Validation of an automated assay for the measurement of cupric reducing antioxidant capacity in serum of dogs
    Camila Peres Rubio
    Asta Tvarijonaviciute
    Silvia Martinez-Subiela
    Josefa Hernández-Ruiz
    José Joaquin Cerón
    BMC Veterinary Research, 12
  • [47] Automated quantification of TSH in serum by a chemiluminescent enzyme immunometric assay: Analytical validation
    Alvarez, MLT
    AndradeOlivie, MA
    Garcia, SC
    Perez, DR
    Dominguez, AS
    Sousa, TR
    Novoa, RA
    ANNALES DE BIOLOGIE CLINIQUE, 1996, 54 (8-9) : 325 - 331
  • [48] Validation of a human immunoturbidimetric assay to measure canine albumin in urine and cerebrospinal fluid
    Gentilini, F
    Dondi, F
    Mastrorilli, C
    Giunti, M
    Calzolari, C
    Gandini, G
    Mancini, D
    Bergamini, PF
    JOURNAL OF VETERINARY DIAGNOSTIC INVESTIGATION, 2005, 17 (02) : 179 - 183
  • [49] Validation of an Automated Immunoturbidimetric Assay for Fibrinogen/Fibrin Degradation Products Measurement and its Correlation to a Semi-Quantitative Latex Agglutination Test
    Martinuzzo, Marta E.
    Ujhelly, Cecilia
    Barrera, Luis H.
    D'Adamo, Maria A.
    Lopez, Marina S.
    Otaso, Juan C.
    Oyhamburu, Jose
    CLINICAL LABORATORY, 2016, 62 (11) : 2085 - 2089
  • [50] An immunoturbidimetric assay for bovine haptoglobin
    Brady N.
    O’Reilly E.L.
    McComb C.
    Macrae A.I.
    Eckersall P.D.
    Comparative Clinical Pathology, 2019, 28 (1) : 21 - 27