Changes in cerebral oxygen saturation during transcatheter aortic valve replacement

被引:16
|
作者
Brodt, Jessica [1 ,2 ]
Vladinov, Greta [3 ]
Castillo-Pedraza, Catalina [1 ]
Cooper, Lebron [1 ,4 ]
Maratea, Edward [1 ]
机构
[1] Univ Miami, Miller Sch Med, Dept Anesthesia, 1400 NW 12th Ave, Miami, FL 33136 USA
[2] Stanford Sch Med, Dept Anesthesia H3580, 300 Pasteur Dr, Stanford, CA 94305 USA
[3] Univ Miami Hosp, 1400 NW 12th Ave, Miami, FL 33136 USA
[4] Univ Tennessee, Coll Med, Dept Anesthesiol, 877 Jefferson Ave,Chandler Bldg,Suit 600, Memphis, TN 38103 USA
关键词
Transcatheter aortic valve replacement; Cerebral oxygen saturation; Rapid ventricular pacing; Aortic stenosis; CARDIAC-SURGERY; DESATURATION; OUTCOMES; STENOSIS;
D O I
10.1007/s10877-015-9758-8
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Cerebral oxygen saturation (rSO(2)) is a non-invasive monitor used to monitor cerebral oxygen balance and perfusion. Decreases in rSO(2) > 20 % from baseline have been associated with cerebral ischemia and increased perioperative morbidity. During transcatheter aortic valve replacement (TAVR), hemodynamic manipulation with ventricular pacing up to 180 beats per minute is necessary for valve deployment. The magnitude and duration of rSO(2) change during this manipulation is unclear. In this small case series, changes in rSO(2) in patients undergoing TAVR are investigated. Ten ASA IV patients undergoing TAVR with general anesthesia at a university hospital were prospectively observed. Cerebral oximetry values were analyzed at four points: pre-procedure (baseline), after tracheal intubation, during valve deployment, and at procedure end. Baseline rSO(2) values were 54.5 +/- 6.9 %. After induction of general anesthesia, rSO(2) increased to a mean of 66.0 +/- 6.7 %. During valve deployment, the mean rSO(2) decreased < 20 % below baseline to 48.5 +/- 13.4 %. In two patients, rSO(2) decreased > 20 % of baseline. Cerebral oxygenation returned to post-induction values in all patients 13 +/- 10 min after valve deployment. At procedure end, the mean rSO(2) was 67.6 +/- 8.1 %. As expected, rapid ventricular pacing resulting in the desired decrease in cardiac output during valve deployment was associated with a significant decrease in rSO(2) compared to post-induction values. However, despite increased post-induction values in all patients, whether related to increased inspired oxygen fraction or reduced cerebral oxygen consumption under anesthesia, two patients experienced a significant decrease in rSO(2) compared to baseline. Recovery to baseline was not immediate, and took up to 20 min in three patients. Furthermore, baseline rSO(2) in this population was at the lower limit of the published normal range. Significant cerebral desaturation during valve deployment may potentially be limited by maximizing rSO(2) after anesthetic induction. Future studies should attempt to correlate recovery in rSO(2) with recovery of hemodynamics and cardiac function, provide detailed neurological assessments pre and post procedure, determine the most effective method of maximizing rSO(2) prior to hemodynamic manipulation, and provide the most rapid method of recovery of rSO(2) following valve deployment.
引用
收藏
页码:649 / 653
页数:5
相关论文
共 50 条
  • [21] Experience with cerebral protection during transcatheter aortic valve replacement: the ALSTER registry
    Schmidt, Tobias
    Schaefer, Ulrich
    Akdag, Ozan
    Sanchez, Oscar D.
    Ladich, Elena
    Thomas, Thielsen
    Schlueter, Michael
    Schewel, Dimitry
    Schewel, Jury
    Kreidel, Felix
    Alessandrini, Hannes
    Kuck, Karl-Heinz
    Frerker, Christian
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (15) : B46 - B47
  • [22] Protection from Cerebral Embolic Events During Transcatheter Aortic Valve Replacement
    Charles F. Rossow
    James M. McCabe
    Current Cardiology Reports, 2016, 18
  • [23] Transcatheter Aortic Valve Replacement During Pregnancy
    Hodson, Robert
    Kirker, Eric
    Swanson, Jeffrey
    Walsh, Craig
    Korngold, Ethan C.
    Ramelli, Sarah
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (10)
  • [24] Transcatheter aortic valve replacement The American perspective on transcatheter aortic valve replacement
    Waksman, Ron
    Rogers, Toby
    EUROPEAN HEART JOURNAL, 2016, 37 (10) : 797 - 799
  • [25] Effects of a dual-filter-based cerebral embolic protection device in transcatheter aortic valve replacement on cerebral oxygen saturation: A prospective pilot study
    Voss, Stephanie
    Ernst, Annick
    Erlebach, Magdalena
    Ruge, Hendrik
    Sideris, Konstantinos
    Bleiziffer, Sabine
    Voss, Bernhard
    Tassani-Prell, Peter
    Mayr, N. Patrick
    JOURNAL OF CARDIAC SURGERY, 2021, 36 (04) : 1241 - 1248
  • [26] Atrioventricular Conduction System Changes During Transcatheter Aortic Valve Replacement (TAVR)
    Clarke, John-Ross D.
    Rathakrishnan, Bharath
    Poulin, Marie-France
    Laham, Roger J.
    Ultimo, Beattie
    Guibone, Kim
    Pinto, Duane S.
    Kiernan, Katherine
    Medline, Alexandra
    Haouzi, Alice
    Omar, Wally
    Tuttle, Mark
    Hardy, Tyler
    Waks, Jonathan W.
    Buxton, Alfred E.
    CIRCULATION, 2023, 148
  • [27] Mitral valve perforation during transcatheter aortic valve replacement
    Higa, Shotaro
    Nagano, Takaaki
    Yamashiro, Satoshi
    Iwabuchi, Masashi
    ASIAN CARDIOVASCULAR & THORACIC ANNALS, 2020, 28 (05): : 276 - 278
  • [28] Transcatheter aortic valve replacement valve in transcatheter aortic valve replacement valve for severe periprosthetic regurgitation
    Nandy, Sneha
    Wan, Siu-Hin
    Klarich, Kyle
    HEART VIEWS, 2020, 21 (01): : 49 - 51
  • [29] Aortic Valve Deformation During Transcatheter Mitral Valve Replacement
    Sugiura, Atsushi
    Weber, Marcel
    Treede, Hendrik
    Nickenig, Georg
    JACC-CARDIOVASCULAR INTERVENTIONS, 2020, 13 (13) : 1603 - 1604
  • [30] Avulsion of Aortic Leaflet During Transcatheter Aortic Valve Replacement
    Patankar, Gautam R.
    Grayburn, Paul A.
    Hebeler, Robert F., Jr.
    Henry, Albert C.
    Stoler, Robert C.
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2016, 29 (05) : 549 - 551