Changes in cerebral oxygen saturation during transcatheter aortic valve replacement

被引:16
|
作者
Brodt, Jessica [1 ,2 ]
Vladinov, Greta [3 ]
Castillo-Pedraza, Catalina [1 ]
Cooper, Lebron [1 ,4 ]
Maratea, Edward [1 ]
机构
[1] Univ Miami, Miller Sch Med, Dept Anesthesia, 1400 NW 12th Ave, Miami, FL 33136 USA
[2] Stanford Sch Med, Dept Anesthesia H3580, 300 Pasteur Dr, Stanford, CA 94305 USA
[3] Univ Miami Hosp, 1400 NW 12th Ave, Miami, FL 33136 USA
[4] Univ Tennessee, Coll Med, Dept Anesthesiol, 877 Jefferson Ave,Chandler Bldg,Suit 600, Memphis, TN 38103 USA
关键词
Transcatheter aortic valve replacement; Cerebral oxygen saturation; Rapid ventricular pacing; Aortic stenosis; CARDIAC-SURGERY; DESATURATION; OUTCOMES; STENOSIS;
D O I
10.1007/s10877-015-9758-8
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Cerebral oxygen saturation (rSO(2)) is a non-invasive monitor used to monitor cerebral oxygen balance and perfusion. Decreases in rSO(2) > 20 % from baseline have been associated with cerebral ischemia and increased perioperative morbidity. During transcatheter aortic valve replacement (TAVR), hemodynamic manipulation with ventricular pacing up to 180 beats per minute is necessary for valve deployment. The magnitude and duration of rSO(2) change during this manipulation is unclear. In this small case series, changes in rSO(2) in patients undergoing TAVR are investigated. Ten ASA IV patients undergoing TAVR with general anesthesia at a university hospital were prospectively observed. Cerebral oximetry values were analyzed at four points: pre-procedure (baseline), after tracheal intubation, during valve deployment, and at procedure end. Baseline rSO(2) values were 54.5 +/- 6.9 %. After induction of general anesthesia, rSO(2) increased to a mean of 66.0 +/- 6.7 %. During valve deployment, the mean rSO(2) decreased < 20 % below baseline to 48.5 +/- 13.4 %. In two patients, rSO(2) decreased > 20 % of baseline. Cerebral oxygenation returned to post-induction values in all patients 13 +/- 10 min after valve deployment. At procedure end, the mean rSO(2) was 67.6 +/- 8.1 %. As expected, rapid ventricular pacing resulting in the desired decrease in cardiac output during valve deployment was associated with a significant decrease in rSO(2) compared to post-induction values. However, despite increased post-induction values in all patients, whether related to increased inspired oxygen fraction or reduced cerebral oxygen consumption under anesthesia, two patients experienced a significant decrease in rSO(2) compared to baseline. Recovery to baseline was not immediate, and took up to 20 min in three patients. Furthermore, baseline rSO(2) in this population was at the lower limit of the published normal range. Significant cerebral desaturation during valve deployment may potentially be limited by maximizing rSO(2) after anesthetic induction. Future studies should attempt to correlate recovery in rSO(2) with recovery of hemodynamics and cardiac function, provide detailed neurological assessments pre and post procedure, determine the most effective method of maximizing rSO(2) prior to hemodynamic manipulation, and provide the most rapid method of recovery of rSO(2) following valve deployment.
引用
收藏
页码:649 / 653
页数:5
相关论文
共 50 条
  • [1] Changes in cerebral oxygen saturation during transcatheter aortic valve replacement
    Jessica Brodt
    Greta Vladinov
    Catalina Castillo-Pedraza
    Lebron Cooper
    Edward Maratea
    Journal of Clinical Monitoring and Computing, 2016, 30 : 649 - 653
  • [2] Cerebral Microembolic Exposure during Transcatheter Aortic Valve Replacement
    Tom, Stephanie
    Trivedi, Jaimin
    Flaherty, Michael
    Grubb, Kendra
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 70 (18) : B268 - B268
  • [3] Cerebral Embolic Protection During Transcatheter Aortic Valve Replacement
    Yashima, Fumiaki
    Briasoulis, Alexandros
    Kuno, Toshiki
    Noguchi, Masahiko
    Ahmad, Hasan
    Zaid, Syed
    Goldberg, Joshua B.
    Malik, Aaqib H.
    Tang, Gilbert H. L.
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2022, 36 : 9 - 13
  • [4] Cerebral Events and Protection During Transcatheter Aortic Valve Replacement
    Freeman, Melanie
    Barbanti, Marco
    Wood, David A.
    Ye, Jian
    Webb, John G.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2014, 84 (06) : 885 - 896
  • [5] Intraoperative Cerebral Perfusion Disturbances During Transcatheter Aortic Valve Replacement
    Fanning, Jonathon P.
    Walters, Darren L.
    Wesley, Allan J.
    Anstey, Chris
    Huth, Samuel
    Bellapart, Judith
    Collard, Caroline
    Rapchuk, Ivan L.
    Natani, Sarvesh
    Savage, Michael
    Fraser, John F.
    ANNALS OF THORACIC SURGERY, 2017, 104 (05): : 1564 - 1568
  • [6] Protection Against Cerebral Embolism During Transcatheter Aortic Valve Replacement
    Kapadia, Samir R.
    Kodali, Susheel
    Makkar, Raj
    Mehran, Roxana
    Lazar, Ronald M.
    Zivadinov, Robert
    Dwyer, Michael G.
    Jilaihawi, Hasan
    Virmani, Renu
    Anwaruddin, Saif
    Thourani, Vinod H.
    Nazif, Tamim
    Mangner, Norman
    Woitek, Felix
    Krishnaswamy, Amar
    Mick, Stephanie
    Chakravarty, Tarun
    Nakamura, Mamoo
    McCabe, James M.
    Satler, Lowell
    Zajarias, Alan
    Szeto, Wilson Y.
    Svensson, Lars
    Alu, Maria C.
    White, Roseann M.
    Kraemer, Carlye
    Parhizgar, Azin
    Leon, Martin B.
    Linke, Axel
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (04) : 367 - 377
  • [7] Cerebral Embolic Protection during Transcatheter Aortic-Valve Replacement
    Kapadia, Samir R. R.
    Makkar, Raj
    Leon, Martin
    Abdel-Wahab, Mohamed
    Waggoner, Thomas
    Massberg, Steffen
    Rottbauer, Wolfgang
    Horr, Samuel
    Sondergaard, Lars
    Karha, Juhana
    Gooley, Robert
    Satler, Lowell
    Stoler, Robert C.
    Messe, Steven R.
    Baron, Suzanne J.
    Seeger, Julia
    Kodali, Susheel
    Krishnaswamy, Amar
    Thourani, Vinod H.
    Harrington, Katherine
    Pocock, Stuart
    Modolo, Rodrigo
    Allocco, Dominic J.
    Meredith, Ian T.
    Linke, Axel
    PROTECTED TAVR Investigators
    NEW ENGLAND JOURNAL OF MEDICINE, 2022, 387 (14): : 1253 - 1263
  • [8] Cerebral oxygen saturation as outcome predictor after transfemoral transcatheter aortic valve implantation
    Seppelt, Philipp C.
    Mas-Peiro, Silvia
    Van Linden, Arnaud
    Iken, Sonja
    Zacharowski, Kai
    Walther, Thomas
    Fichtlscherer, Stephan
    Vasa-Nicotera, Mariuca
    CLINICAL RESEARCH IN CARDIOLOGY, 2022, 111 (08) : 955 - 965
  • [9] Cerebral oxygen saturation as outcome predictor after transfemoral transcatheter aortic valve implantation
    Philipp C. Seppelt
    Silvia Mas-Peiro
    Arnaud Van Linden
    Sonja Iken
    Kai Zacharowski
    Thomas Walther
    Stephan Fichtlscherer
    Mariuca Vasa-Nicotera
    Clinical Research in Cardiology, 2022, 111 : 955 - 965
  • [10] Cerebral protection devices for transcatheter aortic valve replacement
    Cubero-Gallego, Hector
    Pascual, Isaac
    Rozado, Jose
    Ayesta, Ana
    Hernandez-Vaquero, Daniel
    Diaz, Rocio
    Alperi, Alberto
    Avanzas, Pablo
    Moris, Cesar
    ANNALS OF TRANSLATIONAL MEDICINE, 2019, 7 (20)