Comparison of Monte Carlo and analytical dose computations for intensity modulated proton therapy

被引:37
|
作者
Yepes, Pablo [1 ,2 ]
Adair, Antony [1 ,2 ]
Grosshans, David [2 ]
Mirkovic, Dragan [2 ]
Poenisch, Falk [2 ]
Titt, Uwe [2 ]
Wang, Qianxia [1 ,2 ]
Mohan, Radhe [2 ]
机构
[1] Rice Univ, Dept Phys & Astron, MS 315,6100 Main St, Houston, TX 77005 USA
[2] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Unit 1202,1515 Holcombe Blvd, Houston, TX 77030 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2018年 / 63卷 / 04期
关键词
IMPT; Monte Carlo; analytical; proton therapy; particle therapy; dose; comparison; TRACK-REPEATING ALGORITHM; PENCIL BEAM ALGORITHM; MONITOR UNIT; IMPLEMENTATION; DISTRIBUTIONS; RADIOTHERAPY; SIMULATIONS; VALIDATION; IMPACT;
D O I
10.1088/1361-6560/aaa845
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
To evaluate the effect of approximations in clinical analytical calculations performed by a treatment planning system (TPS) on dosimetric indices in intensity modulated proton therapy. TPS calculated dose distributions were compared with dose distributions as estimated by Monte Carlo (MC) simulations, calculated with the fast dose calculator (FDC) a system previously benchmarked to full MC. This study analyzed a total of 525 patients for four treatment sites (brain, head-and-neck, thorax and prostate). Dosimetric indices (D02, D05, D20, D50, D95, D98, EUD and Mean Dose) and a gamma-index analysis were utilized to evaluate the differences. The gamma-index passing rates for a 3%/3 mm criterion for voxels with a dose larger than 10% of the maximum dose had a median larger than 98% for all sites. The median difference for all dosimetric indices for target volumes was less than 2% for all cases. However, differences for target volumes as large as 10% were found for 2% of the thoracic patients. For organs at risk (OARs), the median absolute dose difference was smaller than 2 Gy for all indices and cohorts. However, absolute dose differences as large as 10 Gy were found for some small volume organs in brain and head-and-neck patients. This analysis concludes that for a fraction of the patients studied, TPS may overestimate the dose in the target by as much as 10%, while for some OARs the dose could be underestimated by as much as 10 Gy. Monte Carlo dose calculations may be needed to ensure more accurate dose computations to improve target coverage and sparing of OARs in proton therapy.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Development and commissioning of a multileaf collimator model in Monte Carlo dose calculations for intensity-modulated radiation therapy
    Jang, SY
    Vassiliev, ON
    Liu, HH
    Mohan, R
    Siebers, JV
    MEDICAL PHYSICS, 2006, 33 (03) : 770 - 781
  • [42] Monte Carlo dose verification of prostate patients treated with simultaneous integrated boost intensity modulated radiation therapy
    Dogan, Nesrin
    Mihaylov, Ivaylo
    Wu, Yan
    Keall, Paul J.
    Siebers, Jeffrey V.
    Hagan, Michael P.
    RADIATION ONCOLOGY, 2009, 4
  • [43] Monte Carlo dose verification of prostate patients treated with simultaneous integrated boost intensity modulated radiation therapy
    Nesrin Dogan
    Ivaylo Mihaylov
    Yan Wu
    Paul J Keall
    Jeffrey V Siebers
    Michael P Hagan
    Radiation Oncology, 4
  • [44] Monte Carlo evaluation of Acuros XB dose calculation Algorithm for intensity modulated radiation therapy of nasopharyngeal carcinoma
    Yeh, Peter C. Y.
    Lee, C. C.
    Chao, T. C.
    Tung, C. J.
    RADIATION PHYSICS AND CHEMISTRY, 2017, 140 : 419 - 422
  • [45] Dose-volume comparison of proton therapy and intensity-modulated radiotherapy for prostate cancer
    Vargas, Carlos
    Fryer, Amber
    Mahajan, Chaitali
    Indelicato, Daniel
    Horne, David
    Chellini, Angela
    Mckenzie, Craig
    Lawlor, Paula
    Henderson, Randal
    Li, Zuofeng
    Lin, Liyong
    Olivier, Kenneth
    Keole, Sameer
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (03): : 744 - 751
  • [46] Comparison of proton arc therapy and intensity-modulated proton therapy for pediatric ependymoma
    Henjum, Helge
    Feten, Karoline M.
    Ytre-Hauge, Kristian S.
    Boer, Camilla G.
    Stokkevag, Camilla H.
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S4695 - S4698
  • [47] Monte Carlo Computation of the Effective Dose in Scanning Beam Proton Therapy
    Mirkovic, D.
    Titt, U.
    Sawakuchi, G.
    Zhang, X.
    Li, Y.
    Mohan, R.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [48] A simplified methodology to produce Monte Carlo dose distributions in proton therapy
    Beltran, Chris
    Jia, Yingcui
    Slopsema, Roelf
    Yeung, Daniel
    Li, Zuofeng
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (04): : 2 - 10
  • [49] Validation of a Commercial Monte Carlo Dose Calculation Algorithm for Proton Therapy
    Saini, J.
    St James, S.
    Traneus, E.
    Wong, T.
    Stewart, R.
    Bloch, C.
    MEDICAL PHYSICS, 2016, 43 (06) : 3497 - 3497
  • [50] A Monte Carlo Based Proton Therapy Dose Distribution Verification System
    Beltran, C.
    Jia, Y.
    Slopsema, R.
    Yeung, D.
    Li, Z.
    MEDICAL PHYSICS, 2010, 37 (06)