Design and development of a novel multichannel data acquisition system using labview for an automobile air conditioning application

被引:5
|
作者
Shalgar, Sandeep [1 ]
Bindu, Rupa [1 ]
机构
[1] SP Pune Univ, Dr DY Patil Inst Technol, Dept Mech Engn, Pune, Maharashtra, India
来源
JOURNAL OF THERMAL ENGINEERING | 2022年 / 8卷 / 01期
关键词
Multi Channel Data Acquisition System; Error Analysis; LabVIEW; Automobile Air-Conditioning System; Triggering Circuit; ACCURATE; RELAY;
D O I
10.18186/thermal.1066990
中图分类号
O414.1 [热力学];
学科分类号
摘要
To sustain in the ever-changing environment and to combat the atmospheric effect, development of a highly efficient and an environment friendly air conditioning system which can run in parallel or as an alternative to an existing vapor compression system is the need of the hour and such novel hybrid air conditioning system are under development today. For the parameters attribution mapping of such novel hybrid air conditioning system, todays commercially available data acquisition systems (DAS) need to be customized to the requirements of addition of sensor nodes and their integration with triggering mechanism for actuation of devices for its programmed operation. Therefore, this paper describes the design and development of novel multichannel data acquisition system (NMDAS) for automobile air conditioning application. The details of the hardware design, software design, error analysis and testing of the NMDAS are presented. The proposed NMDAS uses PLC module DVP16SP configured with analog reader DVP 04TC for temperature measurement at 32 nodes and DVP04AD for pressure or humidity measurements at 8 nodes. The triggering circuit for activation of the relay is enabled using NI LabVIEW user interface and PLC data. The output of the NMDAS is integrated with processor by RS 232 port for data storage and processing. The error analysis of temperature, pressure and humidity measurements are done by comparing with reference calibration standards. The average thermal stability of the temperature sensors over the operating range of -5 degrees C to 150 degrees C is 0.0015 degrees C. The average accuracy of pressure transmitters for operating range of pressure 0 to 40bar is estimated 98.219%. The minimum error in the output current is 0.375% and maximum error is 7.125% over relative humidity span of 0%RH to 100% RH respectively. The proposed NMDAS is used for testing of the novel hybrid air conditioning system of automobile during development stage and is found expedient.
引用
下载
收藏
页码:14 / 28
页数:15
相关论文
共 50 条
  • [31] Research of Air-Conditioning Control System Using LabVIEW Software Platform
    Liu Guilan
    INFORMATION AND BUSINESS INTELLIGENCE, PT I, 2012, 267 : 685 - 692
  • [32] Performance evaluation of an automobile air conditioning system using R134a
    Esen, Dilek Ozlem
    MATERIALS SCIENCE AND INFORMATION TECHNOLOGY, PTS 1-8, 2012, 433-440 : 4952 - 4958
  • [33] Design of Automatic Detection System Online for Automobile Air-conditioning Electromagnetic Clutch
    Guo, Youqiang
    Pei, Xuezhu
    2010 2ND INTERNATIONAL CONFERENCE ON COMPUTER AND AUTOMATION ENGINEERING (ICCAE 2010), VOL 1, 2010, : 524 - 529
  • [34] Wireless Data Acquisition System Using The Fusion of ZigBee Technology And LabVIEW
    Rajeshkumar, Shah Mansi
    Habibmiya, Malek Sohel
    2014 INTERNATIONAL CONFERENCE FOR CONVERGENCE OF TECHNOLOGY (I2CT), 2014,
  • [35] Design in Data Acquisition System of Fluke PM6306 Based on LabVIEW
    Hu, Guangyu
    Wei, Xuan
    Pan, Hongqing
    Wang, Yubing
    Ge, Yunjian
    Shuang, Feng
    2015 IEEE INTERNATIONAL CONFERENCE ON INFORMATION AND AUTOMATION, 2015, : 2859 - 2862
  • [36] Design of FMCW radar data acquisition and signal processing system based on Labview
    Leng Jianwei
    Shan Chuanbin
    FRONTIERS OF MANUFACTURING AND DESIGN SCIENCE IV, PTS 1-5, 2014, 496-500 : 1881 - +
  • [37] A study on integrated design conjugation profiles application analysis of scroll profiles for automobile air conditioning
    LiCun Wang
    Li Du
    XianMing Zhang
    XuDong Wang
    Bin Chen
    Sinan H. Hussain
    Science China Technological Sciences, 2011, 54 : 1496 - 1504
  • [38] A study on integrated design conjugation profiles application analysis of scroll profiles for automobile air conditioning
    Sinan H HUSSAIN
    Science China Technological Sciences, 2011, (06) : 1496 - 1504
  • [39] A study on integrated design conjugation profiles application analysis of scroll profiles for automobile air conditioning
    Wang LiCun
    Du Li
    Zhang XianMing
    Wang XuDong
    Chen Bin
    Hussain, Sinan H.
    SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2011, 54 (06) : 1496 - 1504
  • [40] A study on integrated design conjugation profiles application analysis of scroll profiles for automobile air conditioning
    Sinan H HUSSAIN
    Science China(Technological Sciences), 2011, 54 (06) : 1496 - 1504