Comparability and intra-/interobserver reliability of anterior chamber depth measurements with the Pentacam and IOLMaster

被引:19
|
作者
Savant, Vijay [1 ]
Chavan, Randhir [2 ]
Pushpoth, Sreekumari [2 ]
Ilango, B. [2 ]
机构
[1] Birmingham & Midland Eye Ctr, Birmingham B18 7QH, W Midlands, England
[2] Wolverhampton & Midland Cty Eye Infirm, Wolverhampton, W Midlands, England
关键词
D O I
10.3928/1081597X-20080601-11
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To assess the comparability and intra-/interobsever reliability of central anterior chamber depth measurements obtained using the Pentacam and IOLMaster. METHODS: Anterior chamber depth was measured in 50 eyes (25 healthy volunteers)-three times on each eye by two independent observers with each method. A total of 12 measurements were performed on each eye. Analysis of variance was used to analyze the data. Mean values, standard deviations, and confidence limits (95% confidence interval) of the two modalities, two observers, and every observer/modality interaction were calculated. RESULTS: The mean anterior chamber depth values were 3.23 +/- 0.031 mm for the IOLMaster and 3.21 +/- 0.033 mm for the Pentacam. No statistically significant difference was noted in measurements between the two modalities (P=.291) or between the two observers (P=.903). Observer/modality interaction was not significant (P=.643). The confidence limits for observer 1 were 3.223 +/- 0.03 mm and 3.226 +/- 0.03 mm for observer 2. The confidence limits were: observer 1/IOLMaster, 3.23 +/- 0.04 mm; observer 2/IOLMaster, 3.24 +/- 0.04 mm; observer 1/Pentacam, 3.21 +/- 0.04 mm; and observer 2/Pentacam, 3,20 +/- 0.04 mm. The differences in measurements ranged from -0.14 to +0.10 mm for the IOLMaster and from -0.08 to +0.12 mm for the Pentacam The worst deviation from the average eye reading of 3.23 mm was only 0.14 (4.3%). CONCLUSIONS: Good agreement exists between anterior chamber depth measurements by the IOLMaster and Pentacam in the assessment of normal eyes, and they offer observer-independent results. Therefore, the modalities are interchangeable.
引用
收藏
页码:615 / 618
页数:4
相关论文
共 50 条
  • [31] Intra- and interobserver variability of MRI prostate volume measurements
    Bonilla, J
    Stoner, E
    Grino, P
    Binkowitz, B
    Taylor, A
    PROSTATE, 1997, 31 (02): : 98 - 102
  • [32] Anterior chamber measurements using Pentacam rotating Scheimpflug camera
    Rabsilber, TM
    Khoramnia, R
    Auffarth, GU
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (03): : 456 - 459
  • [33] Anterior Chamber Depth Measurement in Pseudophakic Eyes: A Comparison of Pentacam and Ultrasound
    Savini, Giacomo
    Olsen, Thomas
    Carbonara, Claudio
    Pazzaglia, Sebastiano
    Barboni, Piero
    Carbonelli, Michele
    Hoffer, Kenneth J.
    JOURNAL OF REFRACTIVE SURGERY, 2010, 26 (05) : 341 - 347
  • [34] Intra- and Interobserver Reliability of Size Measurement of Morton Neuromas on Sonography
    Park, Young Hwan
    Choi, Won Seok
    Choi, Gi Won
    Kim, Hak Jun
    JOURNAL OF ULTRASOUND IN MEDICINE, 2019, 38 (09) : 2341 - 2345
  • [35] Evaluation of intra- and interobserver reliability in the assessment of the ‘critical trochanter angle’
    Sebastian Serong
    Moritz Schutzbach
    Ivica Zovko
    Marcus Jäger
    Stefan Landgraeber
    Marcel Haversath
    European Journal of Medical Research, 25
  • [36] Intra- and Interobserver Reliability of Digitally Photodocumented Findings in Wrist Arthroscopy
    Loew, S.
    Prommersberger, K. -J.
    Pillukat, T.
    van Schoonhoven, J.
    HANDCHIRURGIE MIKROCHIRURGIE PLASTISCHE CHIRURGIE, 2010, 42 (05) : 287 - 292
  • [37] Evaluation of intra- and interobserver reliability in the assessment of the 'critical trochanter angle'
    Serong, Sebastian
    Schutzbach, Moritz
    Zovko, Ivica
    Jaeger, Marcus
    Landgraeber, Stefan
    Haversath, Marcel
    EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2020, 25 (01)
  • [38] Anterior chamber depth measurement with A-scan ultrasonography, Orbscan II, and IOLMaster
    Hashemi, H
    Yazdani, K
    Mehravaran, S
    Fotouhi, A
    OPTOMETRY AND VISION SCIENCE, 2005, 82 (10) : 900 - 904
  • [39] Intra- and Interobserver Reliability of Quantitative Ultrasound Measurement of the Plantar Fascia
    Rathleff, Michael Skovdal
    Moelgaard, Carsten
    Olesen, Jens Lykkegaard
    JOURNAL OF CLINICAL ULTRASOUND, 2011, 39 (03) : 128 - 134
  • [40] Anterior Chamber Depth Measurements Following Cycloplegia Using Photographic Image Analysis (IOLMaster™) and Anterior Segment Optical Coherence Tomography (Visante™) and Their Relationship to the Haigis Formula Derived Postop Anterior Chamber Depth
    Lyles, G. W.
    Cohen, K. L.
    Aschbrenner, M. W.
    El-Khorazaty, J.
    Lam, D.