Human Responses to the Thermal Comfort in Air-Conditioned Building: A Climate Chamber Study

被引:1
|
作者
Ismail, Ahmad Rasdan [1 ,2 ]
Jusoh, Norfadzilah [1 ]
Zein, Raemy Md [3 ]
机构
[1] Univ Malaysia Kelantan, Fac Creat Technol & Heritage, Bachok 16300, Kelantan, Malaysia
[2] Univ Malaysia Kelantan, Ctr Management Environm Occupat Safety & Hlth CMe, Bachok 16300, Kelantan, Malaysia
[3] Natl Inst Occupat Safety & Hlth NIOSH, Bandar Baru Bangi 43650, Selangor, Malaysia
来源
关键词
Thermal comfort; climate chamber; air conditioned; PMV; PPD index; HUMID TROPICS;
D O I
10.30880/ijie.2022.14.01.027
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
One of the challenges for engineers in designing comfort indoor environments is merging the need of energy savings and thermal comfort of the occupants. However, to assess complex heterogeneous environments created by novel building systems, there is a need for choosing more sophisticated and precise tools. There are many best ways to evaluate thermal comfort, at the same time the most cost and time-consuming one, various modelling tools are widely used. In this paper, we present a human climate chamber as a methodology for indoor environmental research, to predict the thermal comfort. Along with presenting this methodology, the human climate chamber was demonstrated on five supply temperature representing the indoor environment such as conditions for which thermal sensation was predicted with satisfactory accuracy. Based on the presented results, the overall thermal sensation on the body will be influenced mainly by those body segments that have a greatest thermal sensation under different condition's environment (supply temperature). The overall thermal comfort will follow the warmest environment (26 degrees C and 29 degrees C) and the coldest in a cool environment (19 degrees C and 23 degrees C). Furthermore, the overall thermal comfort will closely follow the parts of the body that feel the most uncomfortable in a cool or warm environment. The study found that supply temperature at the 23 degrees C indicates that the PMV is comfortable. The value of PMV in a supply temperature set at 23 degrees C is 0.26. This study contributes to the body knowledge of thermal comfort towards human in the building.
引用
收藏
页码:287 / 295
页数:9
相关论文
共 50 条
  • [1] Thermal comfort in air-conditioned mosques in the dry desert climate
    Al-ajmi, Farraj F.
    [J]. BUILDING AND ENVIRONMENT, 2010, 45 (11) : 2407 - 2413
  • [2] Thermal comfort study of air-conditioned university laboratories
    Hussin, M.
    Ismail, M. R.
    Ahmad, M. S.
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL TECHNOLOGY AND MANAGEMENT, 2014, 17 (05) : 430 - 449
  • [3] THERMAL COMFORT IN AN AIR-CONDITIONED TRACTOR CAB
    KAUFMAN, KR
    TURNQUIST, PK
    SWANSON, RN
    [J]. TRANSACTIONS OF THE ASAE, 1979, 22 (04): : 694 - &
  • [4] Thermal comfort study of an air-conditioned lecture theatre in the tropics
    Cheong, KWD
    Djunaedy, E
    Chua, YL
    Tham, KW
    Sekhar, SC
    Wong, NH
    Ullah, MB
    [J]. BUILDING AND ENVIRONMENT, 2003, 38 (01) : 63 - 73
  • [5] Subjective Perception of Thermal Comfort Study in Air-Conditioned University Laboratories
    Hussin, M.
    Ismail, M. R.
    Ahmad, M. S.
    [J]. PSU-USM INTERNATIONAL CONFERENCE ON HUMANITIES AND SOCIAL SCIENCES, 2013, 91 : 192 - 200
  • [6] Thermal Comfort and Perception Inside Air-Conditioned Areas
    Manasrah, Ahmad
    Guldiken, Rasim
    Reed, Kyle
    [J]. 2016 ASHRAE ANNUAL CONFERENCE PAPERS, 2016,
  • [7] Hybrid Ventilation in an Air-Conditioned Office Building with a Multistory Atrium for Thermal Comfort: A Practical Case Study
    Hsu, Hao-Hsiang
    Chiang, Wei-Hwa
    Huang, Jian-Sheng
    [J]. BUILDINGS, 2021, 11 (12)
  • [8] CFD Analysis on Thermal Comfort and Energy Consumption Effected by Partitions in Air-Conditioned Building
    Aryal, Pradip
    Leephakpreeda, Thananchai
    [J]. 2015 INTERNATIONAL CONFERENCE ON ALTERNATIVE ENERGY IN DEVELOPING COUNTRIES AND EMERGING ECONOMIES, 2015, 79 : 183 - 188
  • [9] Air Flow Distribution Effects on Thermal Comfort in an Air-Conditioned Enclosure
    Khalil, Essam E.
    Alhariry, Gamal
    Mahfouz, Alaa O.
    [J]. 2013 ASHRAE ANNUAL CONFERENCE, 2013,
  • [10] Field study on thermal comfort in naturally ventilated and air-conditioned university classrooms
    Fabozzi, Michael
    Dama, Alessandro
    [J]. INDOOR AND BUILT ENVIRONMENT, 2020, 29 (06) : 851 - 859