The effect of energy recovery device and feed flow rate on the energy efficiency of reverse osmosis process

被引:30
|
作者
Alanezi, Adnan Alhathal [1 ]
Altaee, Ali [2 ]
Sharif, Adel O. [3 ]
机构
[1] Publ Author Appl Educ & Training PAAET, Dept Chem Engn Technol, Coll Technol Studies, POB 42325, Shuwaikh 70654, Kuwait
[2] Univ Technol Sydney, Sch Civil & Environm Engn, Ultimo, NSW 2007, Australia
[3] Univ Surrey, Fac Engn & Phys Sci, Ctr Osmosis Res & Applicat CORA, Chem & Proc Engn Dept, Guildford GU2 7XH, Surrey, England
来源
关键词
Reverse osmosis; Desalination; Energy; Energy recovery device; Seawater; Specific power consumption; CONTAMINANTS; OPTIMIZATION; PERFORMANCE; MEMBRANES; DESIGN;
D O I
10.1016/j.cherd.2020.03.018
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The energy requirements for reverse osmosis (RO) seawater desalination continue to be a major matter of debate. Previous studies have shown the dependence of optimum RO desalination energy on the RO recovery rate. However, they overlooked including the effect of Energy Recovery Device (ERD) and pretreatment on the power consumption. In this work, a computer model was used to analyze the energy requirements for RO desalination, taking into account the effect of ERD efficiencies and pretreatment. The specific power consumption (SPC) of the RO was found to increase with the increase of RO recovery rate when the ERD system was included. The optimum SPC became more dependent on the RO recovery rate when the pretreatment energy was added. The recovery for optimum desalination energy was 46%, 44%, and 40% for the RO system coupled with an ERD of 65%, 80%, and 95% efficiency, respectively. The results showed that RO process could be operated at lower recovery rate and still meet the projected desalination capacity by increasing the feed flow rate and coupling with high-efficiency ERD. A trivial decrease of the total desalination energy was achieved when the feed flow rate increased from 7 m(3)/h to 8 m(3)/h and recovery rate decreased from 46% to 44% by coupling the RO with an ERD of 95% efficiency. This suggests that the RO-ERD system can be operated at a high feed flow rate and low recovery rate without affecting the plant capacity. (C) 2020 Institution of Chemical Engineers. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:12 / 23
页数:12
相关论文
共 50 条
  • [31] Pilot tests of fluid-switcher energy recovery device for seawater reverse osmosis desalination system
    Wang, Zhaocheng
    Wang, Yue
    Zhang, Yanping
    Qi, Bingwei
    Xu, Shichang
    Wang, Shichang
    DESALINATION AND WATER TREATMENT, 2012, 48 (1-3) : 310 - 314
  • [32] THERMODYNAMIC ANALYSIS OF A REVERSE OSMOSIS DESALINATION SYSTEM USING FORWARD OSMOSIS FOR ENERGY RECOVERY
    Banchik, Leonardo D.
    Lienhard, John H., V
    INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION - 2012, VOL 6, PTS A AND B, 2013, : 1017 - 1029
  • [33] MODEL PREDICTIVE CONTROL OF FEED FLOW REVERSAL IN A REVERSE OSMOSIS DESALINATION PROCESS
    Bartman, Alex R.
    McFall, Charles W.
    Christofides, Panagiotis D.
    Cohen, Yoram
    2009 AMERICAN CONTROL CONFERENCE, VOLS 1-9, 2009, : 4860 - 4867
  • [34] Reverse osmosis desalination process with feed flow reversal operation: experimental studies
    Li, Tian
    Tang, Di
    Song, Jie
    Law, Adrian Wing-Keung
    DESALINATION AND WATER TREATMENT, 2019, 144 : 339 - 344
  • [35] Improving water flux distribution and energy efficiency in reverse osmosis for high-recovery water reuse
    Lee, Younggeun
    Kang, Weekwan
    Lee, Woonyoung
    Lee, Jeong Hoon
    Kim, Jungbin
    DESALINATION, 2024, 585
  • [36] Energy optimization of a multistage reverse osmosis process for seawater desalination
    Ahunbay, M. Goktug
    Tantekin-Ersolmaz, S. Birgul
    Krantz, William B.
    DESALINATION, 2018, 429 : 1 - 11
  • [37] A SPECIFIC ENERGY RECOVERY PUMPING SYSTEM FOR REVERSE-OSMOSIS DESALINATION
    GOUBEAU, P
    LEROY, P
    DESALINATION, 1983, 44 (MAY) : 199 - 206
  • [38] Thermodynamic Analysis of a Reverse Osmosis Desalination Unit with Energy Recovery System
    Al-Zahrani, A.
    Orfi, J.
    Al-Suhaibani, Z.
    Salim, B.
    Al-Ansary, H.
    ISWEE'11, 2012, 33 : 404 - 414
  • [39] Review of performance improvement of energy recovery turbines in the reverse osmosis desalination
    Qiu, Guanhua
    Wang, Shenghui
    Song, Daiwang
    Liu, Sihan
    Wang, Haitao
    DESALINATION AND WATER TREATMENT, 2018, 119 : 70 - 73
  • [40] Thermodynamic Analysis of Osmotic Energy Recovery at a Reverse Osmosis Desalination Plant
    Feinberg, Benjamin J.
    Ramon, Guy Z.
    Hoek, Eric M. V.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2013, 47 (06) : 2982 - 2989