Demonstration of Fine-Pitch High-Resolution X-ray Transition-Edge Sensor Microcalorimeters Optimized for Energies below 1 keV

被引:6
|
作者
Sakai, K. [1 ,2 ]
Adams, J. S. [1 ,2 ]
Bandler, S. R. [1 ]
Beaumont, S. [1 ,2 ]
Chervenak, J. A. [1 ]
Datesman, A. M. [1 ,3 ]
Finkbeiner, F. M. [1 ,4 ]
Kelley, R. L. [1 ]
Kilbourne, C. A. [1 ]
Miniussi, A. R. [1 ,2 ]
Porter, F. S. [1 ]
Sadleir, J. E. [1 ]
Smith, S. J. [1 ,2 ]
Wakeham, N. A. [1 ,2 ]
Wassell, E. J. [1 ,3 ]
Jaeckel, F. T. [5 ]
McCammon, D. [5 ]
Eckart, M. E. [6 ]
Ryu, K. [7 ]
机构
[1] NASA, Goddard Space Flight Ctr, Greenbelt, MD 20771 USA
[2] Univ Maryland Baltimore Cty, CRESST 2, Baltimore, MD 21250 USA
[3] KBRwyle, Lexington Pk, MD 20653 USA
[4] Sigma Space Corp, 4600 Forbes Blvd, Lanham, MD 20706 USA
[5] Univ Wisconsin, Madison, WI 53706 USA
[6] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA
[7] MIT, Lincoln Lab, Lexington, MA 02421 USA
关键词
Transition-edge sensors; Microcalorimeters; Lynx LXM;
D O I
10.1007/s10909-020-02409-2
中图分类号
O59 [应用物理学];
学科分类号
摘要
In this paper, we report on X-ray transition-edge sensor (TES) microcalorimeters optimized to have the best possible energy resolution for a limited energy range for the incoming X-rays, such as an energy resolution of 0.3 eV full width half maximum (FWHM) for energies up to approximate to 0.8 keV as is desirable for one of the Lynx X-ray Microcalorimeter subarrays. The test array we have fabricated has 60 x 60 sensors on a pitch of 50 mu m, and has 46 x 46 mu m(2) absorbers that are one micrometer thick. We have measured a spectral energy resolution of the same device using 3 eV photons delivered through an optical fiber. For the one-photon 3 eV line, we have obtained an energy resolution of 0.25 eV FWHM, which is consistent with the estimated performance based on the signal size and noise. Further measurements will determine how the energy resolution degrades with energy. Based upon measurements of the TES transition characteristics, it appears that this level of energy resolution should be achievable up to 0.5 keV, and the performance will then gradually degrade to the measured energy resolution of around 2.3 eV at 1.5 keV. In this paper, we describe the full design and characterization of this detector, and discuss the performance limits of pixels designs like this.
引用
收藏
页码:949 / 954
页数:6
相关论文
共 42 条
  • [31] High-Resolution Near-Edge X-ray Absorption Fine Structure Study of Condensed Polyacenes
    Rocco, M. L. M.
    Haeming, M.
    de Moura, C. E. V.
    Barbatti, M.
    Rocha, A. B.
    Schoell, A.
    Umbach, E.
    JOURNAL OF PHYSICAL CHEMISTRY C, 2018, 122 (50): : 28692 - 28701
  • [32] Position-sensing transition-edge sensors for large-field, high-energy-resolution X-ray imaging spectroscopy
    Figueroa-Feliciano, E
    Stahle, CK
    Finkbeiner, FM
    Li, M
    Lindeman, MA
    Tralshawala, N
    Stahle, CM
    X-RAY AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY XI, 2000, 4140 : 419 - 427
  • [33] High-resolution hard X-ray and gamma-ray spectrometers based on superconducting absorbers coupled to superconducting transition edge sensors
    van den Berg, ML
    Chow, DT
    Loshak, A
    Cunningham, MF
    Barbee, TW
    Frank, M
    Labov, SE
    X-RAY AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY XI, 2000, 4140 : 436 - 444
  • [34] Chemical and vibronic effects in the high-resolution near-edge X-ray absorption fine structure spectra of polystyrene isotopomers
    Urquhart, SG
    Ade, H
    Rafailovich, M
    Sokolov, JS
    Zhang, Y
    CHEMICAL PHYSICS LETTERS, 2000, 322 (05) : 412 - 418
  • [35] Iron local structure in tektites and impact glasses by extended X-ray absorption fine structure and high-resolution X-ray absorption near-edge structure spectroscopy
    Giuli, G
    Pratesi, G
    Cipriani, C
    Paris, E
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2002, 66 (24) : 4347 - 4353
  • [36] High-resolution study of the x-ray resonant Raman scattering process around the 1s absorption edge for aluminium, silicon, and their oxides
    Szlachetko, J.
    Dousse, J. -Cl.
    Berset, M.
    Fennane, K.
    Szlachetko, M.
    Hoszowska, J.
    Barrett, R.
    Pajek, M.
    Kubala-Kukus, A.
    PHYSICAL REVIEW A, 2007, 75 (02):
  • [37] Misfit strain induced lattice distortions in heteroepitaxially grown LaxCa1-xMnO3 thin films studied by extended x-ray absorption fine structure and high-resolution x-ray diffraction
    Miniotas, A
    Vailionis, A
    Svedberg, EB
    Karlsson, UO
    JOURNAL OF APPLIED PHYSICS, 2001, 89 (04) : 2134 - 2137
  • [38] D2R1: A 2-D X-Ray Detector for CdTe-Based Fine Pitch and High-Energy Resolution Imaging Spectroscopy
    Baudin, D.
    Dubos, S.
    Gevin, O.
    Limousin, O.
    Maier, D.
    Michalowska, A.
    Renaud, D.
    Serrano, P.
    Takahashi, T.
    Watanabe, S.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2018, 65 (07) : 1408 - 1415
  • [39] A high-resolution near-edge x-ray absorption fine structure investigation of the molecular orientation in the pentacene/poly(3,4-ethylenedioxythiophene): poly(styrenesulfonate) pentacene/system
    Casu, M. B.
    Cosseddu, P.
    Batchelor, D.
    Bonfiglio, A.
    Umbach, E.
    JOURNAL OF CHEMICAL PHYSICS, 2008, 128 (01):
  • [40] Self-assembled carbon nanotubes on gold: Polarization-modulated infrared reflection-absorption spectroscopy, high-resolution X-ray photoemission spectroscopy, and near-edge X-ray absorption-fine structure spectroscopy study
    Kocharova, Natalia
    Leiro, Jarkko
    Lukkari, Jukka
    Heinonen, Markku
    Skala, Tomas
    Sutara, Frantisek
    Skoda, Michal
    Vondracek, Martin
    LANGMUIR, 2008, 24 (07) : 3235 - 3243