Clinical Analysis of the Diagnostic Accuracy and Time of Execution of a Transillumination Caries Detection Method Compared to Bitewing Radiographs

被引:1
|
作者
Pelliccioni, Gian Andrea [1 ]
Gatto, Maria Rosaria Antonella [1 ]
Bolognesi, Silvia [1 ,2 ]
Dal Fiume, Daniele [2 ]
Sebold, Maicon [3 ]
Breschi, Lorenzo [1 ]
机构
[1] Alma Mater Studiorum Univ Bologna, Dept Biomed & Neuromotor Sci, Via San Vitale 59, I-40125 Bologna, Italy
[2] Dal Fiume Private Practice, Via G Leopardi 101, I-40026 Imola, Italy
[3] Univ Estadual Campinas, Dept Restorat Dentisty, Operat Dent Div, Piracicaba Dent Sch, Ave Limeira 901, BR-13414903 Piracicaba, Brazil
关键词
fiber optic technology; transillumination; radiography; bitewing; dental caries; diagnosis; oral; ROC curve; INFRARED LIGHT TRANSILLUMINATION; ASSESSMENT SYSTEM ICDAS; INTERNATIONAL CARIES; AGREEMENT;
D O I
10.3390/jcm10204780
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purposes: this clinical study evaluated the accuracy and execution time of a digital imaging fiber-optic transillumination (DIFOTI) technique for the detection of approximal caries in posterior teeth compared to intra-oral examination associated with bitewing radiographs. Methods: one hundred patients were selected and submitted to clinical inspection and bitewing radiographs. The outcomes of this process were converted into scores, according to the International Caries Detection and Assessment System (ICDAS): 0-sound tooth; 1, 2, and 3-carious lesion confined within enamel; 4, 5, and 6-dentin carious lesion. Subsequently, an independent investigator acquired digital images of the same teeth using a DIFOTI device (DIAGNOcam, Kavo Dental), which were also converted into ICDAS scores. The time required for executing diagnostic procedures was measured. The clinical sensitivity and specificity of DIFOTI were analyzed by receiver operating characteristic (ROC) curves. The time necessary to perform the diagnostic methods was evaluated by Mann-Whitney U (alfa = 0.05). Results: the overall test accuracy for the DIFOTI-based device ranged from 0.717 to 0.815 (area under the ROC curve) with p < 0.0001 for all ICDAS scores. Bitewing radiographs took almost twice the time required by DIFOTI (p < 0.001). Conclusions: the DIFOTI-based device DIAGNOcam provided accurate detection of approximal caries in posterior teeth, even at early stages. The technique employed for transillumination caries diagnosis by the same device took less time than conventional bitewing radiographs. Clinical Relevance: transillumination devices, such as DIAGNOcam, can be accurately used for caries diagnosis in approximal surfaces of posterior teeth, demanding less clinical time and without radiation-related risks.
引用
收藏
页数:10
相关论文
共 49 条
  • [41] Diagnostic accuracy of multiplex real-time PCR approaches compared with cultivation -based detection methods: Monitoring the endopathogenic microbiota pre and post photo-activated disinfection
    Pourhajibagher, Maryam
    Bahador, Abbas
    PHOTODIAGNOSIS AND PHOTODYNAMIC THERAPY, 2018, 22 : 140 - 146
  • [42] Diagnostic accuracy of artificial intelligence assisted clinical imaging in the detection of oral potentially malignant disorders and oral cancer: a systematic review and meta-analysis
    Li, JingWen
    Kot, Wai Ying
    McGrath, Colman Patrick
    Chan, Bik Wan Amy
    Ho, Joshua Wing Kei
    Zheng, Li Wu
    INTERNATIONAL JOURNAL OF SURGERY, 2024, 110 (08) : 5034 - 5046
  • [43] Diagnostic accuracy of 18F-Sodium Fluoride PET or PET/CT for the detection of bone metastasis in patients with breast and prostate cancer compared with other imaging techniques: A meta-analysis
    Sheikhbahaei, Sara
    Jones, Krystyna M.
    Salas-Fragomeni, Roberto A.
    Marcus, Charles
    Rowe, Steven
    Solnes, Lilja
    Javadi, Mehrbod
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58
  • [44] Diagnostic Accuracy of Real-time Polymerase Chain Reaction in Detection of Clostridium difficile in the Stool Samples of Patients With Suspected Clostridium difficile Infection: A Meta-Analysis
    Deshpande, Abhishek
    Pasupuleti, Vinay
    Rolston, David D. K.
    Jain, Anil
    Deshpande, Narayan
    Pant, Chaitanya
    Hernandez, Adrian V.
    CLINICAL INFECTIOUS DISEASES, 2011, 53 (07) : E81 - E90
  • [45] REAL-TIME ANALYSIS OF HOLTER MONITORING USING A DIGITAL-COMPUTER SYSTEM WITH SOLID-STATE MEMORY - EVALUATION OF DIAGNOSTIC-ACCURACY AND CLINICAL FEASIBILITY
    MEINERTZ, T
    FINKE, R
    KASPER, W
    HOFMANN, T
    JUST, H
    BIOMEDIZINISCHE TECHNIK, 1985, 30 (11): : 291 - 301
  • [46] A systematic review and meta-analysis: the diagnostic accuracy of methylated SEPTIN9 for the detection of hepatocellular carcinoma and the clinical evaluation of its use in combination with other surveillance modalities
    Chandrapalan, Subashini
    Bannaga, Ayman
    Weidner, Alice
    Hitchins, Megan P.
    Arasaradnam, Ramesh P.
    SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 2022, 57 (04) : 473 - 480
  • [47] Magnetic Resonance Imaging-targeted Biopsy May Enhance the Diagnostic Accuracy of Significant Prostate Cancer Detection Compared to Standard Transrectal Ultrasound-guided Biopsy: A Systematic Review and Meta-analysis
    Schoots, Ivo G.
    Roobol, Monique J.
    Nieboer, Daan
    Bangma, Chris H.
    Steyerberg, Ewout W.
    Hunink, M. G. Myriam
    EUROPEAN UROLOGY, 2015, 68 (03) : 438 - 450
  • [48] Comparing the diagnostic accuracy of rapid antigen detection tests to real time polymerase chain reaction in the diagnosis of SARS-CoV-2 infection: A systematic review and meta-analysis
    Lee, Jonghoo
    Song, Jae-Uk
    Shim, Sung Ryul
    JOURNAL OF CLINICAL VIROLOGY, 2021, 144
  • [49] Evaluation by latent class analysis of a magnetic capture based DNA extraction followed by real-time qPCR as a new diagnostic method for detection of Echinococcus multilocularis in definitive hosts
    Maas, Miriam
    van Roon, Annika
    Dam-Deisz, Cecile
    Opsteegh, Marieke
    Massolo, Alessandro
    Deksne, Gunita
    Teunis, Peter
    van der Giessen, Joke
    VETERINARY PARASITOLOGY, 2016, 230 : 20 - 24