Three-dimensional analysis of the airway with cone-beam computed tomography

被引:29
|
作者
Stratemann, Scott
Huang, John C. [1 ]
Maki, Koutaro [2 ]
Hatcher, David [3 ]
Miller, Arthur J. [1 ]
机构
[1] Univ Calif San Francisco, Sch Dent, Div Orthodont, Dept Orofacial Sci, San Francisco, CA 94143 USA
[2] Showa Univ, Dept Orthodont, Tokyo, Japan
[3] Diagnost Digital Imaging, Sacramento, CA USA
关键词
OBSTRUCTIVE SLEEP-APNEA; VOLUME SEGMENTATION ANALYSIS; CROSS-SECTIONAL AREA; CHILDREN; CT; GROWTH; CONFIGURATION; NASOPHARYNX; OROPHARYNX; MORPHOLOGY;
D O I
10.1016/j.ajodo.2010.12.019
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: In this study, using a cone-beam computed tomography system, we evaluated the airways of 30 adults. Methods: The shapes of the 3-dimensional volume of the airway were analyzed and compared among the subjects by using surface superimposition software techniques. Results: The airway had the greatest variability in the hypopharynx, in the region below the epiglottis, and above the vocal folds. Moderate variation was apparent at the nares, behind the soft palate, and at the base of the tongue. Conservation of form was seen at the central portion of the nasal airway surrounding the inferior turbinate. Conclusions: The potential for comparing the shape of the airway among subjects is possible. (Am J Orthod Dentofacial Orthop 2011; 140:607-15)
引用
下载
收藏
页码:607 / 615
页数:9
相关论文
共 50 条
  • [21] Cone-Beam Computed Tomography: Accuracy of Three-dimensional Cephalometry Analysis and Influence of Patient Scanning Position
    Frongia, Gianluigi
    Piancino, Maria Grazia
    Bracco, Pietro
    JOURNAL OF CRANIOFACIAL SURGERY, 2012, 23 (04) : 1038 - 1043
  • [22] Assessing the Accuracy of Lateral Cephalogram in Quantifying Three-Dimensional Pharyngeal Airway Morphology Compared to Cone-Beam Computed Tomography
    Abdulhameed, Syed Ashique
    Riyaz, Abdul Kader
    Almutairy, Mohammed
    Khan, N. Salman
    Jayakumar, Saikarthik
    Gaonkar, Prachi
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (03)
  • [23] Reliability of three-dimensional measurements of the upper airway on cone beam computed tomography images
    Chen, Hui
    Aarab, Ghizlane
    Parsa, Azin
    de Lange, Jan
    van der Stelt, Paul F.
    Lobbezoo, Frank
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2016, 122 (01): : 104 - 110
  • [24] Automated 3-Dimensional Airway Analysis From Cone-Beam Computed Tomography Data
    Schendel, Stephen A.
    Hatcher, David
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2010, 68 (03) : 696 - 701
  • [25] Accuracy and reliability of cone-beam computed tomography for airway volume analysis
    Ghoneima, Ahmed
    Kula, Katherine
    EUROPEAN JOURNAL OF ORTHODONTICS, 2013, 35 (02) : 256 - 261
  • [26] Reproducibility of three-dimensional cephalometric landmarks in cone-beam and low-dose computed tomography
    R. Olszewski
    L. Frison
    M. Wisniewski
    J. M. Denis
    S. Vynckier
    G. Cosnard
    F. Zech
    H. Reychler
    Clinical Oral Investigations, 2013, 17 : 285 - 292
  • [27] Cone-beam computed tomography and three-dimensional orthodontics. Where we are and future perspectives
    Leonardi, Rosalia
    JOURNAL OF ORTHODONTICS, 2019, 46 : 45 - 48
  • [28] Three-dimensional PSF characterization of circle-plus-arc cone-beam computed tomography
    Chen, ZK
    Ning, R
    Yu, Y
    Conover, D
    Medical Imaging 2005: Physics of Medical Imaging, Pts 1 and 2, 2005, 5745 : 664 - 675
  • [29] Methods to evaluate the performance of kilovoltage cone-beam computed tomography in the three-dimensional reconstruction space
    Zhang, J.
    Bao, Z. R.
    Huang, X. T.
    Jiang, D. Z.
    Xie, C. H.
    Zhou, Y. F.
    Liu, H.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2019, 17 (02): : 189 - 202
  • [30] Reliability of different three-dimensional cephalometric landmarks in cone-beam computed tomography: A systematic review
    Sam, Alycia
    Currie, Kris
    Oh, Heesoo
    Flores-Mir, Carlos
    Lagravere-Vich, Manuel
    ANGLE ORTHODONTIST, 2019, 89 (02) : 317 - 332