Choosing sample sizes for various blood parameters of broiler chickens with normal and non-normal observations

被引:21
|
作者
Nunes, R. V. [1 ]
Broch, J. [1 ]
Wachholz, L. [1 ]
de Souza, C. [1 ]
Damasceno, J. L. [1 ]
Oxford, J. H. [2 ]
Bloxham, D. J. [2 ]
Billard, L. [3 ]
Pesti, G. M. [2 ]
机构
[1] State Univ Western Parana, Dept Agr Sci, BR-45328479 Marechal Candido Rodondo, PR, Brazil
[2] Univ Georgia, Dept Poultry Sci, Athens, GA 30602 USA
[3] Univ Georgia, Dept Stat, Athens, GA 30602 USA
关键词
blood; sample size; distribution; statistical design; SERUM BIOCHEMICAL PARAMETERS; GROWTH-PERFORMANCE; SILVER NANOPARTICLES; IMMUNE; QUALITY; TRAITS; IMPACT;
D O I
10.3382/ps/pey217
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
Experimental power is a measure of the ability of an experiment to detect differences between treatment means. Researchers design experiments and then calculate the probability that differences are simply due to chance, the null hypothesis. The objective of the analyses reported here was to determine the appropriate number of samples to demonstrate significant differences of various magnitudes from broiler chicken blood constituents. Over 800 samples were taken for a study of the effects of sample storage time, serum vs. plasma, light intensity, and fed vs. fasted birds on blood cholesterol, triglycerides, uric acid, glucose, total protein (TP), albumin, globulin, alanine aminotransferase (ALT), aspartate aminotransferase, gammaGT, creatinine, alkaline phosphatase, Ca and P. Various transformations increased the QQ plot R-2 values from 0.000 to 0.149 or 0.00 to 17.62%. Most of the QQ plot R-2 values were at or above 0.90. The 1/x(2) transformation of blood P data showed the biggest increase in QQ plot R-2 (0.846 to 0.995). The different standard deviations and coefficients of variation (CVs) found for each variable resulted in widely different numbers of replicates needed to detect differences in 2 treatment means. The extremes were glucose with a CV of 6.9% and ALT with a CV of 39.7%. For glucose, 15 replicates are needed to find a 10% difference in 97% of experiments; for ALT, 15 replicates would detect a 50% difference 91% of the time. The use of parameters such as cholesterol, glucose, TP, albumin, and globulin showed low CVs, indicating they may be considered as stable parameters. The lower CVs make it possible to find differences with a smaller number of replicates used in studies. As reported, the phosphorus values did not have a normal distribution of the data, so a transformation of these data could be an alternative to better discuss the results found.
引用
收藏
页码:3746 / 3754
页数:9
相关论文
共 50 条
  • [41] Reliability-based robust optimization design of automobile components with non-normal distribution parameters
    Yang Zhou
    Zhang Yimin
    Huang Xianzhen
    Zhang Xufang
    Tang Le
    [J]. CHINESE JOURNAL OF MECHANICAL ENGINEERING, 2013, 26 (04) : 823 - 830
  • [42] Reliability-based robust optimization design of automobile components with non-normal distribution parameters
    Zhou Yang
    Yimin Zhang
    Xianzhen Huang
    Xufang Zhang
    Le Tang
    [J]. Chinese Journal of Mechanical Engineering, 2013, 26 : 823 - 830
  • [43] Reliability-based Robust Optimization Design of Automobile Components with Non-normal Distribution Parameters
    YANG Zhou
    ZHANG Yimin
    HUANG Xianzhen
    ZHANG Xufang
    TANG Le
    [J]. Chinese Journal of Mechanical Engineering, 2013, (04) : 823 - 830
  • [44] Reliability-based robust design of beam structure stiffness with non-normal distribution parameters
    He, Xiangdong
    Zhang, Yimin
    Liu, Qiaoling
    Wen, Bangchun
    [J]. Guti Lixue Xuebao/Acta Mechanica Solida Sinica, 2007, 28 (04): : 411 - 414
  • [45] Effects of curcumin or nanocurcumin on blood biochemical parameters, intestinal morphology and microbial population of broiler chickens reared under normal and cold stress conditions
    Rahmani, Marzieh
    Golian, Abolghasem
    Kermanshahi, Hassan
    Bassami, Mohammad Reza
    [J]. JOURNAL OF APPLIED ANIMAL RESEARCH, 2018, 46 (01) : 200 - 209
  • [46] Determination of Confidence Intervals in Non-normal Data: Application of the Bootstrap to Cocaine Concentration in Femoral Blood
    Desharnais, Brigitte
    Camirand-Lemyre, Felix
    Mireault, Pascal
    Skinner, Cameron D.
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 2015, 39 (02) : 113 - 117
  • [47] Reliability-based Robust Design of Coil Tube-Spring with Non-Normal Random Parameters
    Yang, Zhou
    Zhang, Yimin
    Huang, Jing
    [J]. DYNAMICS FOR SUSTAINABLE ENGINEERING, 2011, VOL 4, 2011, : 1922 - 1929
  • [48] Reliability Based Robust Design of Vehicle Rear-Axle Housing with Non-Normal Random Parameters
    Yang, Zhou
    Zhang, Yi-Min
    [J]. 2011 INTERNATIONAL CONFERENCE ON QUALITY, RELIABILITY, RISK, MAINTENANCE, AND SAFETY ENGINEERING (ICQR2MSE), 2011, : 839 - 844
  • [50] Effects of different heat stress periods on various blood and meat quality parameters in young Arbor Acer broiler chickens
    Tang, Shu
    Yu, Jimian
    Zhang, Miao
    Bao, Endong