Study of the application and validation of the Ethological Coding System for Interviews (ECSI)

被引:2
|
作者
Paas-Oliveros, Lya K. [1 ]
Villanueva Valle, Javier [1 ]
Gonzalez-Arredondo, Susana I. [1 ]
Fresan, Ana [2 ]
Arango de Montis, Ivan [3 ]
Bruene, Martin [4 ]
Munoz Delgado, Jairo [1 ]
机构
[1] Inst Nacl Psiquiatria Ramon de la Fuente Muniz, Direcc Neurociencias, Lab Cronoecol & Etol Humana, Mexico City 14370, DF, Mexico
[2] Inst Nacl Psiquiatria Ramon de la Fuente Muniz, Subdirecc Invest Clin, Lab Epidemiol Clin, Mexico City 14370, DF, Mexico
[3] Inst Nacl Psiquiatria Ramon de la Fuente Muniz, Direcc Serv Clin, Clin Trastornos Limitrofes Personalidad, Mexico City 14370, DF, Mexico
[4] Ruhr Univ Bochum, Dept Psiquiatria Psicoterapia & Med Prevent, Bochum, Germany
关键词
Human ethology; ethogram; clinical interview; nonverbal behavior; NONVERBAL BEHAVIOR; COMMUNICATION; SCHIZOPHRENIA;
D O I
10.17711/SM.0185-3325.2015.005
中图分类号
R749 [精神病学];
学科分类号
100205 ;
摘要
Background Psychotherapeutic diagnosis is largely based on verbal explorations and/or psychological tests. In contrast, the relevance of non-verbal communication is often disregarded. Here, we aim to provide a tool to measure and assess non-verbal behavior in clinical interviews, based on the Ethological Coding System for Interviews (ECSI), developed by Troisi (1999), which was translated and validated in Spanish. An ethogram is a catalogue of behaviours or patterns of behaviour, which are operationalized and grouped in categories such as affiliation, flight, assertiveness, relaxation and so forth. Method Study1. The ECSI was translated into Spanish. Three "blind" observers registered the frequencies of the behavioral patterns of the patient. The recordings were made in 15 seconds intervals during the first and the last 10 minutes of a clinical interview. An inter-observer reliability of r=0.989, p<0.001 was obtained. Study 2. Based on the first study, it was considered pertinent to add behavioral patterns, as well as rearranging and redefining the proposed categories. The three "blind" observers performed the same task as in study 1 with a second video-recording. Aside from the frequency of the observed behaviours, the duration of the behavior was measured. An inter-observer reliability of r=0.993, p<0.001 was obtained. Results and discussion The ECSI has proven a reliable and valid tool for the examination of patients' nonverbal behaviour during interviews. It is hoped that the ECSI can be added to the diagnostic process during psychotherapeutic sessions.
引用
收藏
页码:41 / 46
页数:6
相关论文
共 50 条
  • [41] Application and analysis of wave front coding technology on TMC system
    Guo, Xiaohu
    Zhao, Yuejin
    Wu, Yijian
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2015, 44 (07): : 2075 - 2079
  • [42] A Study of Collisions in Wireless Network Coding System
    He, Jianping
    Yang, Jiahai
    An, Changqing
    Li, Xuenong
    2008 1ST IFIP WIRELESS DAYS (WD), 2008, : 173 - +
  • [43] Validation of a Behavioral Coding System for Measuring Mutually Responsive Orientation in Intimate Relationships
    Brock, Rebecca L.
    Ramsdell, Erin L.
    Franz, Molly R.
    Volk, Sage
    PSYCHOLOGICAL ASSESSMENT, 2020, 32 (08) : 713 - 725
  • [44] The application of Feedforward Transmit Diversity to a system with Adaptive Modulation and Coding
    Bevan, DDN
    Ward, CR
    Tong, W
    IEEE 54TH VEHICULAR TECHNOLOGY CONFERENCE, VTC FALL 2001, VOLS 1-4, PROCEEDINGS, 2001, : 438 - 441
  • [45] Application of Genetic Algorithm for Flight System Verification and Validation
    Sacco, Gian Franco
    Barltrop, Kevin J.
    Lee, Cin-Young
    Horvath, Gregory A.
    Terrile, Richard J.
    Lee, Seungwon
    2009 IEEE AEROSPACE CONFERENCE, VOLS 1-7, 2009, : 3250 - 3255
  • [46] Application and validation of the Automated Truck Performance Measurement System
    Wolf, GP
    Peterson, FJ
    PROCEEDINGS OF THE 1998 ASME/IEEE JOINT RAILROAD CONFERENCE, 1998, : 127 - 134
  • [47] Validation of system codes for plant application on selected experiments
    Koch, M. K.
    Risken, T.
    Agethen, K.
    Bratfisch, C.
    KERNTECHNIK, 2016, 81 (02) : 121 - 124
  • [48] AN INITIAL VALIDATION OF A STUDY STRATEGY SYSTEM
    SIMPSON, ML
    HAYES, CG
    STAHL, N
    CONNOR, RT
    WEAVER, D
    JOURNAL OF READING BEHAVIOR, 1988, 20 (02): : 149 - 180
  • [49] Application of microscopic simulation model calibration and validation procedure - Case study of coordinated actuated signal system
    Park, Byungkyu
    Won, Jongsun
    Yun, Ilsoo
    TRAFFIC SIGNAL SYSTEMS AND REGIONAL SYSTEMS MANAGEMENT 2006, 2006, (1978): : 113 - +
  • [50] The validation of a swimming turn wall-contact-time measurement system: a touchpad application reliability study
    Brackley, Victoria
    Ball, Kevin
    Tor, Elaine
    SPORTS BIOMECHANICS, 2019, 18 (06) : 595 - 607