Temperature-programmed retention indices for GC and GC-MS of hydrocarbon fuels and simulated distillation GC of heavy oils

被引:0
|
作者
Song, CS [1 ]
Lai, WC [1 ]
Reddy, KM [1 ]
Wei, BL [1 ]
机构
[1] Penn State Univ, Clean Fuels & Catalysis Program, Energy Inst, University Pk, PA 16802 USA
关键词
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
引用
收藏
页码:147 / 210
页数:64
相关论文
共 50 条
  • [11] Programmable control of column selectivity for temperature-programmed GC
    Coutant, C
    Sacks, R
    ANALYTICAL CHEMISTRY, 2000, 72 (21) : 5450 - 5458
  • [12] Changes in the molecular composition of crude oils during their preparation for GC and GC-MS analyses
    Ahmed, M
    George, SC
    ORGANIC GEOCHEMISTRY, 2004, 35 (02) : 137 - 155
  • [13] Determination of boiling point distribution by TG using a novel crucible and comparison with true boiling point distillation and simulated distillation by GC-MS and Py-GC/MS
    Liu, Hongchuan
    He, Lei
    Wang, Wei
    Wang, Linyang
    Ma, Duo
    Wang, Jing
    Yao, Qiuxiang
    Sun, Ming
    CHEMICAL ENGINEERING JOURNAL, 2024, 484
  • [14] An environmentally significant experiment using GC/MS and GC retention indices in an undergraduate analytical laboratory
    GuistoNorkus, R
    Gounili, G
    Wisniecki, P
    Hubball, JA
    Smith, SR
    Stuart, JD
    JOURNAL OF CHEMICAL EDUCATION, 1996, 73 (12) : 1176 - 1178
  • [15] An Environmentally Significant Experiment Using GC/MS and GC Retention Indices in an Undergraduate Analytical Laboratory
    Guisto-Norkus, R.
    Gounili, G.
    Wisniecki, P.
    Hubball, J. A.
    Journal of Chemical Education, 73 (12):
  • [16] Fate and identification of spilled oils and petroleum products in the environment by GC-MS and GC-FID
    Wang, ZD
    Fingas, M
    ENERGY SOURCES, 2003, 25 (06): : 491 - 508
  • [17] Application of GC-MS retention index in forensic routine
    Ferrari Jr, Ettore
    Ferreira, Luisa Pereira e
    Lordeiro, Rogerio Araujo
    Machado, Yuri
    FORENSIC CHEMISTRY, 2024, 41
  • [18] FACTORS AFFECTING THE REPRODUCIBILITY AND RELIABILITY OF RETENTION SIMULATION IN ANY FORM OF TEMPERATURE-PROGRAMMED CAPILLARY GC
    GUAN, YF
    LI, LG
    ZHOU, LM
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1995, 18 (09): : 593 - 596
  • [19] UTILIZATION OF ROHRSCHNEIDER CONCEPT AND TEKLER EQUATION IN LINEAR TEMPERATURE-PROGRAMMED GC - PRECALCULATION OF RETENTION DATA
    SANTIUSTE, JM
    CHROMATOGRAPHIA, 1995, 40 (1-2) : 28 - 32
  • [20] GC(Retention Indices), GC-MS, and 13C NMR of Two Citral-Rich Cymbopogon Leaf Oils: C. Flexuosus and C. tortilis
    Ottavioli, Josephine
    Bighelli, Ange
    Casanova, Joseph
    Bui Thi Bang
    Pham Van Y
    SPECTROSCOPY LETTERS, 2009, 42 (08) : 506 - 512