Oversizing of HVAC system: Signatures and penalties

被引:93
|
作者
Djunaedy, Ery [1 ]
van den Wymelenberg, Kevin [1 ]
Acker, Brad [1 ]
Thimmana, Harshana [1 ]
机构
[1] Univ Idaho, Integrated Design Lab, Boise, ID 83702 USA
关键词
Sizing; Oversizing; Rightsizing; RTU;
D O I
10.1016/j.enbuild.2010.10.011
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Design engineers commonly oversize HVAC systems with the justification of needing a reasonable safety factor to manage periods more extreme than the specific design conditions. Unfortunately, the safety factor easily becomes excessive. The design engineers minimize their professional risk, and by doing so they are actually asking the building owner to pay an immediate penalty due to increased first cost of equipment and an ongoing penalty due to maintenance and energy use implications. The penalties associated with excessive safety factors are often not communicated to the client. This paper presents the results of a study of "rightsizing" rooftop HVAC systems. The study included intensive interviews with HVAC designers investigating the design process and extensive field measurement of rooftop units (RTUs) during peak cooling conditions. This paper focuses on defining the signature of oversizing, i.e. how to use the physical measurements to quantify the degree of oversizing of an RTU and how to estimate the penalty of oversizing in terms of energy consumption and peak electricity demand. Utility companies incentive programs have not yet identified mechanisms for incentivizing rightsizing of HVAC system. The methodology described in this paper can be used as the basis for such programs. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:468 / 475
页数:8
相关论文
共 50 条
  • [31] SPECIFYING THE RIGHT HVAC SYSTEM.
    Daryanani, Sital
    Actual Specifying Engineer, 1972, 28 (03): : 64 - 66
  • [32] INSTALLING AND MAINTAINING HVAC SYSTEM DAMPERS
    GERHOLD, RJ
    PLANT ENGINEERING, 1979, 33 (16) : 80 - 83
  • [33] Smart sensor controller for HVAC system
    Kang, Chia Chao
    Tan, Jian Ding
    Ariannejad, Mohammadmahdi
    Bhuiyana, Mohammad Arif Sobhan
    Ng, Zi Neng
    Yong, Stevan Choong Hong
    ENERGY REPORTS, 2023, 9 : 60 - 63
  • [34] Modeling a Thermoelectric HVAC System for Automobiles
    Junior, C. S.
    Strupp, N. C.
    Lemke, N. C.
    Koehler, J.
    JOURNAL OF ELECTRONIC MATERIALS, 2009, 38 (07) : 1093 - 1097
  • [35] Study and practice on HVAC system commissioning
    Nakahara, N
    PROCEEDINGS OF THE 4TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS 1 AND 2, 2003, : 44 - 61
  • [36] New HVAC System for Cultural Preservation
    Grabon, Michel
    Anderson, Jackie
    Bushnell, Peter
    Calvo, Aritz
    Chadwick, William
    ASHRAE JOURNAL, 2015, 57 (06) : 20 - 34
  • [37] HVAC SYSTEM OF THE SEAVANS MULTIUSE COMPLEX
    ISHIKAWA, M
    YAZAWA, K
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1994, 36 (12): : 28 - &
  • [38] HVAC system design of recreation center
    Wang, PB
    BUILT ENVIRONMENT AND PUBLIC HEALTH, PROCEEDINGS, 2004, : 442 - 445
  • [39] HVAC system attack detection dataset
    Elnour, Mariam
    Meskin, Nader
    Khan, Khaled
    Jain, Raj
    DATA IN BRIEF, 2021, 37
  • [40] Large HVDC/HVAC system simulator
    Zangeneh, BZ
    Shoulaie, A